Methods of studying cells

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/10

encourage image

There's no tags or description

Looks like no tags are added yet.

11 Terms

1
New cards

What is magnification

Magnification is the amount of times an image is enlarged by

2
New cards

What is resolution

Resolution is the ability of a microscope to distinguish between two separate points

3
New cards

What is the effect of increasing magnification on resolution?

Increasing the magnification does no effect on the resolution

4
New cards

What is the difference between a light and electron microscope?

Light microscope has a much lower magnification (1500x compared to 1,500,000x)

Light microscope has a much higher resolution (0.2μm compared to 0.0002μm)

Light microscopes use light whereas electron microscopes use electrons

5
New cards

What are features of the transmission microscope?

  • Electromagnets focus a beam of electrons which is transmitted through the specimen

  • Better resolution because electrons actually pass through the specimen so can detect and focus better, especially on internal structures

  • Can only be used on thinner specimen because electrons need to pass through the structure

  • Images are 2D as a result


6
New cards

What are features of the scanning microscope?

  • Scans a beam of electrons across the specimen which knocks off electrons from the specimen (which are gathered in a cathode ray tube to form an image)

  • Electron scan the surface of the specimen so produces a 3D image

  • Works on thick specimens because they don't need to pass through the specimen.


7
New cards

Why do SEM’s have a reduced level of detail than TEM’s?

  • Do not penetrate deeply into the cell so cannot detect internal structures

  • So reduced fine detail can be resolved


8
New cards

What are the stages of analysing cell components?

  • Homogenisation

  • Filtration

  • Ultracentrifugation


9
New cards

Describe the steps in homogenisation

  • Sample is grinded/blended to break the cell surface membrane and release organelles into the solution.

  • The solution must be cold to reduce enzyme activity which may break down the organelle,

  • The solution must be isotonic to prevent cellular damage due to movement of water via osmosis

  • The solution must be buffered so it maintains a neutral pH to prevent denaturation of enzymes and proteins


10
New cards

Describe the steps in filtration

  • Solution is passed through a gauze

  • Filter removes large tissue and cell debris

  • Only organelles pass through


11
New cards

Describe the steps in ultracentrifugation

  • This is put into a test tube and spun in the centrifuge at a low speed

  • Heaviest, most dense organelles reside at the bottom, forming the pellet (nucleus is usually at the bottom)

  • Lighter organelles are suspended above in the supernatant in the fluid above

  • Supernatant is then removed and placed into another tube and spun in the centrifuge at a high speed, separating the heaviest organelles from the lower, lighter organelles

  • This forms another pellet, usually mitochondria, and supernatant above it

  • This is repeated until all the organelles are separated out into a higher speed each time