attenuation
reduction in radiation beam intensity as it traverses matter by the absorption &/or deflection of photons
intensity decreases as thickness increases
effect of intensity of transmitted beam on thickness of the barrier
linear attenuation coefficient
the probability of interaction / unit thickness (how absorbent the material is per unit of length)
linear attenuation coefficient
- increases as Z of the absorber increases
- depends on the energy of the incident photons & absorber density
- usually determined experimentally
transmission factor
fraction of original beam which successfully traverses the absorber
transmission factor
the percent remaining of the incident beam
half value layer (HVL)
thickness of a material required to attenuate 1/2 of a monoenergetic radiation beam
tenth value layer
thickness of material required to reduce the intensity of the beam to 10% of its incident value
mean free path
average distance traveled by a photon before undergoing an interaction
mean free path
analogous to mean lifetime in the decay process
mass attenuation coefficient
linear attenuation coefficient corrected for absorber density
mass attenuation coefficient
probability of an interaction in a volume
mass attenuation coefficient of a mixture
weighted sum of each element's mass attenuation coefficient
beam hardening
result of lower energy photons being filtered out of a polyenergetic beam by an absorber
broad beam geometry
norm in daily practice with radioactive emissions
broad beam effects
attributable to scatter caused by material overlying the radioactive source
buildup factor
factor which corrects the transmission factor for broad beam conditions (given in a table as a calculated value, derive the factor by cross referencing)