1/27
Looks like no tags are added yet.
Standard Adjustable Bed
Provides position changes and patient comfort. Watch out for bed rail safety and lock wheels.
Turning Frame (Stryker)
Allows 180-degree rotation for severe spinal conditions. Ensure patient safety straps are secure.
Air-Fluidized Support Bed (Clinitron)
Uses air-driven silicone beads for severe burns/ulcers. Monitor patient for fluid loss and dehydration.
Air Suspension Bed
Redistributes weight for pressure ulcer prevention. Watch out for skin shear during transfers.
Ventilator
Provides mechanical breathing support. Prevent fluid condensation in tubing from draining into airway.
Vital Signs Monitor
Continuously measures heart rate, blood pressure, and respiration. Verify lead placement upon movement.
Pulse Oximeter
Non-invasively measures blood oxygen saturation. Watch for poor peripheral circulation causing false readings.
Pulmonary Artery Catheter (Swan-Ganz)
Directly measures pulmonary artery pressure. Avoid tension on line during transfers.
Intracranial Pressure Monitor (ICP)
Monitors pressure inside the skull. Avoid neck flexion and prevent dislodging the line.
Central Venous Pressure Catheter
Measures right atrial pressure and delivers intravenous fluids. Watch for air embolism risk.
Arterial Line (A Line)
Continuously measures arterial blood pressure. Rapid severe bleeding occurs if line disconnects.
Nasogastric Tube (NG Tube)
Delivers nutrition or medication from nose to stomach. Keep head elevated to prevent aspiration.
Gastric Tube (G Tube)
Provides enteral nutrition directly into stomach. Maintain head elevation during and after feedings.
IV Feeding (TPN)
Delivers complete nutrition directly into central vein. Monitor blood glucose levels and infection risk.
Intravenous Infusion Line (IV)
Administers fluids, medications, or blood products. Avoid line pulling and monitor for infiltration.
Foley Catheter
Indwelling catheter for continuous urine drainage. Keep drainage bag below bladder level.
External Catheter (Condom Catheter)
Non-invasive urinary collection device for males. Inspect skin regularly for skin breakdown.
Suprapubic Catheter
Surgically placed urinary catheter above pubic bone. Keep stoma site clean and unkinked.
Nasal Cannula
Delivers low-flow supplemental oxygen via nostrils. Watch for skin breakdown behind ears.
Oronasal Mask
Covers nose and mouth for higher oxygen delivery. Monitor for tightness and aspiration risk.
Tracheostomy Mask
Delivers humidified oxygen directly over tracheostomy stoma. Monitor for excessive mucus accumulation.
Chest Drainage System
Evacuates air or fluid from pleural space. Keep drainage collection bottle upright and low.
Ostomy Device
Collects abdominal stool or urine output. Ensure proper seal to protect skin integrity.
Halo Traction Device
Immobilizes cervical spine via skull pins and vest. Never pull on halo frame uprights.
External Fixator
Stabilizes bone fractures externally using frame and pins. Perform regular pin site care.
Patient-Controlled Analgesia (PCA)
Allows patient self-administration of pain medication. Only the patient may press administration button.
Dialysis
Filters metabolic waste and excess fluid from blood. Avoid blood pressure measurements on arteriovenous shunt arm.
Surgical Drains (Hemovac / JP Drain)
Removes post-surgical wound fluid via negative pressure suction. Maintain suction compression of bulb/reservoir.