Sonography labs are only as good as
the equipment within the lab
sonographer performing the study
radiologist reading the studies
QA programs are essential for
patient care
Goals of QA
proper equipment operation
detect gradual changes
minimize downtime
reduce non-diagnostic exams
reduce repeat scans
Gold standard
imaging test that is considered the most accurate test for that type of study
Sensitivity
how good is the test at finding positive exams?
Specificity
how good is the test at deciding if an exam is normal?
Accuracy
how good is the test overall? how good is the test at finding both positive and negative results
Reliability
is the test consistent? does it consistently provide accurate results
Positive predictive value (PPV)
how many abnormal (positive) exams your imaging test correctly identifies as positive
Negative predictive value (NPV)
how many normal (negative) exams your imaging test correctly identifies as normal
Preventative maintenance
routine electrical evaluation to ensure there will be no harm to the sonographer or patient
AIUM suggests all equipment should be evaluated and calibrated
ANNUALLY
Daily operations evaluated by the sonographer
fraying of electrical cords or transducer cords
tears in wiring casing
evaluate the face of the transducer for cracks or chips
evaluate the keyboard for sticky keys
examine the track ball
check for caliper malfunctions or depth adjustments
Performance testing imaging capabilities include:
axial resolution (LARRD)
lateral resolution (LATA)
vertical depth
horizontal calibration
overall registration of data
Performance testing phantoms
calibration and slice-thickness test objects
tissue mimicking phantoms
doppler phantoms
Phantoms are objective standards which means:
they are NOT open to interpretation
Calibration test objects
test the measurement accuracy of the machine
contain strategically located steel pins
speed of sound is identical to soft tissue
does not have attenuation properties
often called the AIUM test object
Test objects evaluate the accuracy and performance of the system:
axial resolution
lateral resolution
caliper accuracy
dead zone
Tissue equivalent phantoms
test objects or grayscale test objects that evaluate a machine’s grayscale sensitivity and contrast resolution
often combined with calibration test objects to create a general purpose phantom
Tissue equivalent phantoms perform very similar to soft tissue:
speed of sound (1.54 km/s)
attenuation
scattering characteristics
echogenicity
grayscale evaluation
Doppler phantoms
test objects are used to evaluate the flow direction, the depth capability of the doppler beam, accuracy of the sample volume location, and measured velocity
Types of doppler phantoms
flow phantom
vibrating string phantom
moving belt phantom
Slice-thickness phantom
1 ½ D transducer!!
evaluates the elevation resolution, or the thickness portion, of the sound beam perpendicular to the imaging plane
measures beam geometry perpendicular to the imaging plane
Accreditation means:
labs have met specific, comprehensive guidelines that govern departmental administration and policies, patient care, scanning protocols, and procedures
AIUM
American institute of ultrasound medicine
AB, small parts, gynecology, OB, vascular
IAC
intersocietal accreditation commission
vascular and echocardiography
ACR
American college of radiology
Ab, gynecology, small parts, OB, and vascular
Professional credentialing organizations
ARDMS - American registry for diagnostic medical sonography
CCI - cardiovascular credential international
ARRT - american registry of radiographic technologists