1/49
Looks like no tags are added yet.
The centrifugal pump on fire apparatus serves as a:
Non-positive displacement pump
A centrifugal pump contains an impeller assembly with the impeller riding on:
Wear rings
In a centrifugal pump, the passage for water that enlarges as it nears the discharge outlet of the pump is the:
Volute
Under certain conditions, ___ lock occurs, and a centrifugal pump will not develop discharge pressure with air in the pump
Air
The fire service employs 3 types of centrifugal pumps: single-stage, two-stage, and
Ganged
The single-stage fire pump is sometimes known as the:
Double-suction impeller
Water enters both eyes of the single-stage impeller in order to cancel:
Lateral thrust
The stripping edges in the opposed discharge volutes divert water into two streams ___ degrees apart:
180
Two-stage centrifugal pumps can switch from volume to pressure mode by use of a:
Transfer valve
The process of switching a centrifugal pump between pressure and volume is known as:
Changeover
Switching a two-stage centrifugal pump from volume to pressure:
Can double the discharge pressure
In a two-stage centrifugal pump, the D/O must not exceed a NPDP of ___ when switching between pressure and volume modes
50psi (350 kPa)
What type of valve is essential to the operation of a two-stage centrifugal fire pump?
Clapper
Fire pumpers that must supply sprinklers and standpipes in high-rise buildings may use a single-stage, high-pressure centrifugal pump when discharge pressures are higher than ___
250psi (1750 kPa)
What is the term used when no water flows from the discharge side of the pump, possibly resulting in pump damage?
Deadheading
Newer model centrifugal pumps may come with a thermal relief valve that allows overheated water to circulate:
Between the pump and the main water tank
To seal the impeller shaft on a centrifugal pump, manufacturers use:
Packing rings
On a midship pumper, power reaches the pump that is located in line behind the engine and transmission through a:
Split-shaft transfer case
Fire pumps can be configured to operate over a range of capacities determined by the piping arrangement and the:
Apparatus gear ratio
To prevent an automatic transmission gear selector from moving during a pumping operation or a manual transmission from slipping out of gear:
There is a lock on the transmission or shift lever
The collar that slides across a saft in a midship transfer case may not make it across due to misaligned or mushroomed teeth, known as a ___ condition
But-tooth
A power take off (PTO) pump is powered by the vehicle’s transmission through a(n):
Idler gear
When using a PTO pumper during pump-and-roll operations and supplying hoselines, the D/O should drive the vehicle while monitoring the:
Pressure gauge
Pumpers with a rear-engine PTO (REPTO) design are powered by:
The engine’s flywheel
Fire department pumpers with a front mounted pump:
Are susceptible to freezing
Apparatus with rear-mount pumps offer key advantages such as more usable compartment space and:
Even weight distribution
Pumps powered by a gasoline or diesel engine independent of the vehicle drive engine are known as a(n):
Auxiliary pump
Located on the pump operator’s panel, a meter that helps in monitoring the vehicle’s electrical system along with a voltmeter is the:
Ammeter
The master intake gauge is also known as a(n):
Compound gauge
During drafting, pump capacity is reached when the vacuum gauge reaches:
20 in (-70 kPa)
When operating the pump with water from a hydrant or a supply line from another pumper, the master intake gauge will show:
Residual pressure
Te master pump discharge gauge reflects:
Overall discharge pressure
According to NFPA 1900, pumpers with a tank capacity equal to or greater than 500 gal (2000 L) should be able to flow at least:
500gpm (2000 L/min) or capacity of the pump, whichever is less
What is the device in modern pumps that will prevent damage to the pump if the tank-to-pump valve is open when the pump receives water under pressure?
Check valve
On pump intakes, as the piping nears the pump, it typically tapers to a(n) ___ shape to eliminate the vortices that may occur in water that flows through circular piping
Square
Based on NFPA 1900, a sufficient number of ___ discharge openings must be provided to flow the rated capacity of the pump
2.5in (65mm)
The most common type actuator for ball-type valves on pump discharges are push-pull handles and handles that are:
Quarter turn
NFPA 1900 requires all intakes and discharges that are 3in (77mm) or greater to be equipped with:
Slow-acting controls
On a pressure governor, RPM/Throttle mode is used when:
Drafting or supplying water
The electronic pressure governor features cavitation protection by returning the engine to idle when the intake pressure falls below:
30 psi (210 kPa)
In a discharge relief valve, the slave valve is controlled by a spring-loaded:
Pilot valve
Intake relief valves open when the intake pressure rises above the required operating pressure by more than:
10 psi (70 kPa)
The type of pump used for drafting is a:
Positive displacement pump
The pump manufacturer’s operating manual should specify the preferred RPM for priming, but generally, the range is:
1000 - 1200 RPM
A pump cooler valve recirculates water from the discharge of the pump to the:
Pump intake
A type of auxiliary cooler on a pumper that uses small tubes surrounded by a water jacket connected to the discharge of the fire pump is the:
Marine cooler
If a pump cannot develop the necessary pressure or flow, it may be due to:
Worn wear rings
According to NFPA 1900, pressure control devices must control discharge pressure within:
30 psi (210 kPa)
NFPA 1900 and 1910 specify that a fire pump in good condition will achieve at least __ in Hg of vacuum
22
According to NFPA 1900, the accuracy points for discharge gauges on a fire pump are:
1050 kPa, 1400 kPa, and 1750 kPa