Immunology Lab: Erythrocyte Sedimentation Rate (OB) and ELISA Techniques

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/22

flashcard set

Earn XP

Description and Tags

Comprehensive flashcards covering the diagnostic principles, methodology, and clinical interpretations of Erythrocyte Sedimentation Rate (Odczyn Biernackiego - OB) and Enzyme-Linked Immunosorbent Assay (ELISA) variants.

23 Terms

1
New cards

Who first described the erythrocyte sedimentation rate (OB) in 1894, and what method of blood preparation was used?

Edmund Biernacki in 1894, who described in detail the sedimentation phenomenon of red blood cells within one hour in venous blood diluted with sodium citrate.

2
New cards

According to the Westergren and Wintrobe reference table, what are the normal ESR values for healthy adult men and women up to 50 years of age?

For men up to 50 years of age, the normal range is 3–8 mm/h3\text{--}8\,\text{mm/h}; for women up to 50 years of age, the normal range is 6–11 mm/h6\text{--}11\,\text{mm/h}.

3
New cards

What are the standard ESR reference ranges for newborns, infants, and individuals over 50 years of age?

  • Newborns: 0–2 mm/h0\text{--}2\,\text{mm/h}

  • Infants: 12–17 mm/h12\text{--}17\,\text{mm/h}

  • Women over 50 years: up to 30 mm/h30\,\text{mm/h}

  • Men over 50 years: up to 20 mm/h20\,\text{mm/h}


4
New cards

Why is the erythrocyte sedimentation rate (OB) test clinically inapplicable in pregnant women?

Because in pregnant women, the ESR value can reach three-digit levels (>100 mm/h>100\,\text{mm/h}), making it unsuitable for clinical diagnosis in this group.

5
New cards

What physiological property prevents erythrocytes from aggregating, and how does disease alter this to accelerate ESR?

Under physiological conditions, a negative surface charge on the erythrocyte membrane (the zeta potential) causes mutual electrostatic repulsion. In disease states, altered plasma protein levels (fibrinogen, globulins, and albumins) alter the relative electrical charge, facilitating rouleaux formation and accelerating sedimentation.

6
New cards

What are the normal relative densities of erythrocytes and plasma that enable sedimentation?

The relative density of normal erythrocytes is 1,095 kg/l1{,}095\,\text{kg/l}, and the density of plasma is 1,027 kg/l1{,}027\,\text{kg/l}.

7
New cards

Which three serum proteins have the greatest influence on the ESR (OB) outcome?

Fibrinogen, immunoglobulins, and albumin.

8
New cards

What clinical conditions and physiological states cause an accelerated ESR?

  • Increased acute-phase protein synthesis

  • Acute and chronic inflammation

  • Traumas and surgical procedures

  • Neoplasms

  • Gammopathies

  • Reduced albumin concentration (liver cirrhosis, nephrotic syndrome)

  • Decreased erythrocyte count (anemia) (Physiological exceptions: pregnancy, puerperium, menstruation, and age up to 6 months)


9
New cards

What pathological factors cause a slowing of the erythrocyte sedimentation rate?

  • Increased erythrocyte count (polycythemia and polycythemia vera)

  • Abnormal erythrocyte morphology (sickle cell anemia)

  • Fibrinogen deficiency


10
New cards

What are the three sequential phases of the erythrocyte sedimentation process?

  1. Rouleaux formation phase (0–20 min0\text{--}20\,\text{min}): RBCs aggregate into rouleaux; no sedimentation occurs.

  2. Sedimentation phase (15–30 min15\text{--}30\,\text{min}): RBC aggregates fall at a constant velocity under gravity.

  3. Erythrocyte compression phase (25–60 min25\text{--}60\,\text{min}): sedimentation velocity drops to zero, and cells pack densely at the bottom.


11
New cards
<p>What layers are identified in the Westergren tube, and what plasma measurements demarcate normal versus elevated results after 60 minutes?</p>

What layers are identified in the Westergren tube, and what plasma measurements demarcate normal versus elevated results after 60 minutes?

From top to bottom, the tube contains plasma, a buffy coat (leukocyte-platelet layer), and packed red blood cells (RBC). After 60 min60\,\text{min}, a normal result is <20 mm< 20\,\text{mm} of plasma, while an elevated result is >25 mm> 25\,\text{mm} of plasma.

12
New cards

What environmental conditions and anticoagulant specifications are required for the classical Westergren method?

Venous whole blood must be collected in 3,2%3{,}2\% sodium citrate at a 4:14:1 ratio (1 ml1\,\text{ml} blood to 0,25 ml0{,}25\,\text{ml} sodium citrate). The testing system must remain undisturbed at 18–25 ∘C18\text{--}25\,^{\circ}\text{C}, protected from vibrations, temperature fluctuations, and direct sunlight.

13
New cards

What are the primary immunological functions of IgG, IgM, IgA, IgD, and IgE?

  • IgG: Most abundant serum antibody; long-term protection, neutralizes pathogens, crosses the placenta.

  • IgM: Produced early in immune responses; forms pentamers for efficient neutralization.

  • IgA: Dominates mucosal surfaces (digestive, respiratory, urogenital tracts) as a first line of defense.

  • IgD: Participates in B lymphocyte activation.

  • IgE: Mediates allergic reactions and defense against parasitic infections.


14
New cards

What immunological mechanism triggers Type I hypersensitivity, and what is the therapeutic aim of IgG in allergy immunotherapy?

Allergens induce specific IgE synthesis by B cells; IgE binds receptors on mast cells and basophils. Re-exposure cross-links bound IgE, causing degranulation and release of histamine and other mediators. In immunotherapy, increasing allergen-specific IgG levels allows IgG to compete with IgE and neutralize allergens before degranulation occurs.

15
New cards

What is ELISA, who discovered it, and what diagnostic technique did it replace?

ELISA (enzyme-linked immunosorbent assay) is a solid-phase immunoenzymatic assay that detects and quantifies proteins via enzyme-catalyzed colorimetric reactions. It was developed in the 1960s by Peter Perlmann and Eva Engvall (Stockholm University) and Anton Schuurs and Bauke van Weemen (Netherlands) as a safer alternative to radioactive radioimmunoassays (RIA).

16
New cards

What standard microplate format is utilized for ELISA, and what is the function of the blocking step?

Polystyrene or plexiglass 96-well microplates (88 rows ×12\times 12 columns) are used. The blocking step, performed with ovalbumin or non-fat milk, coats unoccupied polystyrene binding sites to prevent non-specific protein adsorption during subsequent incubation steps.

17
New cards
<p>Identify the four ELISA formats shown in the diagram and explain their structural differences.</p>

Identify the four ELISA formats shown in the diagram and explain their structural differences.

  1. Direct: Antigen bound to the plate is detected directly by an enzyme-labeled primary antibody.

  2. Indirect: Antigen bound to the plate binds an unlabeled primary antibody, detected by an enzyme-labeled secondary antibody.

  3. Sandwich: Capture antibody immobilized on the plate binds antigen, which is then bound by a detection antibody.

  4. Competitive: Immobilized antibody binds a mixture of sample antigen and labeled antigen competing for binding sites.


18
New cards

Which ELISA variants are used to quantify antibodies versus antigens, and why?

Direct and indirect ELISA are used for antibody quantification and assessing immune response intensity. Sandwich and competitive ELISA are used for measuring antigen concentrations.

19
New cards

What are the primary advantages and disadvantages of direct ELISA?

  • Advantages: Fastest and simplest format; absence of a secondary antibody prevents cross-reactivity.

  • Disadvantages: Low commercial availability of enzyme-labeled primary antibodies for uncommon antigens (requiring labor-intensive in-house labeling); reduced sensitivity and specificity in complex protein mixtures; potential loss of epitope integrity upon surface immobilization.


20
New cards

What advantages does indirect ELISA provide over direct ELISA, and what is its main drawback?

It offers greater sensitivity due to signal amplification by secondary antibodies and greater cost-efficiency, as a single labeled secondary antibody conjugate can be used across multiple assays. The main drawback is a longer procedure time and the possibility of non-specific cross-reactions caused by the secondary antibody.

21
New cards

How does sandwich ELISA achieve superior specificity and sensitivity over direct antigen-coating methods?

By pre-coating the plate with capture antibodies, only the target antigen is selectively extracted from complex matrices, preventing non-specific competition for plate surface binding. This format provides a 3–5-fold3\text{--}5\text{-fold} (or greater) increase in sensitivity over direct coating assays.

22
New cards

How does competitive ELISA function, and what are its key clinical and analytical applications?

Labeled antigens compete with sample antigens for binding to immobilized antibodies; signal intensity is inversely proportional to analyte concentration. It is used for small molecules unable to bind two antibodies simultaneously (e.g., steroid hormones, drug residues, metabolites, supplements) in sports anti-doping control and food allergen testing.

23
New cards

In the indirect ELISA protocol for allergen-specific IgE determination, which secondary antibody conjugate, substrate, and detection wavelength are used?

The assay uses a secondary antibody against human IgE conjugated to horseradish peroxidase (HRP), tetramethylbenzidine (TMB) as the enzymatic substrate, and optical density measurement at a wavelength of 450 nm450\,\text{nm}.