waterseal trap
Each plumbing fixture, excepting those having integral traps, shall be separately trapped by an approved-type _____
three (3)
One trap may serve a set of not more than _____ single compartment sinks or laundry tubs of the same depth or three (3) lavatories immediately adjacent to each other and in the same room if the waste outlets are not more than 0.75 meter apart and the trap is centrally located when three (3) compartments are installed.
1 trap arm
1 trap is equal to
Integral Trap
Kind of trap for water closet
P-Trap
Kind of trap for lavatory, shower drain and floor drain
Drum Trap
Kind of trap for bath tub
food waste disposal unit
Each such _____ shall be connected to a separate trap.
0. 6 meter
The vertical distance between a fixture outlet and the trap weir shall be as short as practicable, but in no case shall the tailpiece from any fixture exceed _____ in length.
siphonage and back-pressure
Each plumbing fixture trap. except as otherwise provided in this Code shall be protected against _____ and ____ by a properly placed vent pipe.
in no case less than two times the diameter of the trap arm
Minimum distance from vent to trap.
ninety (90)
A trap arm may change direction without the use of a cleanout when such change of direction does not exceed _____ degrees.
76 mm
But for trap arms ____ in diameter and larger, the change of direction not exceeding 22%, no cleanout is required and for change of direction greater than 22% a cleanout is required at the bend
water closets
The vent pipe opening from a soil or waste pipe, except for _____ and similar fixtures, shall not be below the weir of the trap.
0.76 m
Distance of trap arm to vent: 32 mm dia. trap
1.07 m
Distance of trap arm to vent: 38 mm dia. trap
1.52 mm
Distance of trap arm to vent: 51 mm dia. trap
1.83 mm
Distance of trap arm to vent: 76 mm dia. trap
3.05 mm
Distance of trap arm to vent: 102 mm dia. trap
1.8 meters or 6 feet
The developed length between the trap of a water closet or similar fixture measured from the top of closet ring (closet flange) to inner edge of vent shall not exceed ______________.
Gauge 17 B & S (1.1 mm)
Gauge of exposed and readily accessible brass tubing trap.
trap arm
The trap size should be the same size as the (____________) to which it is connected.
self-cleaning
Each trap, except one for an interceptor or similar device shall be ____________.
brass
An exposed and readily accessible drawn ______________ tubing trap, not less than Gauge 17 B & S (1.1 mm) may be used on fixtures discharging domestic sewage but shall exclude urine.
drum trap
No ____ shall be installed without a vent.
True - but may be installed if permitted by AA for special condition
T or F: Drum trap is prohibited
1) S trap
2) Bell trap
3) Crown-vented trap
Prohibited traps (3)
102 mm
Each fixture trap shall have a water seal of not less than 51 mm and not more than _____ deep except where a deeper seal is found necessary.
erect and true
Traps shall be set ___________ with respect to their water seals.
backwater valve
When subject to reverse flow of sewage or liquid waste, such floor drains shall be equipped with an approved ___________ valve.
shut-off valve
When automatic trap priming devices are installed, they shall be accessible for maintenance and provided by an accessible ____________ valve.
Interceptors or clarifiers
_________________ shall be provided when, in the judgment of the Administrative Authority, they are necessary for the proper handling of liquid wastes containing grease, flammable wastes, sand, solids, acid or alkaline substances, or other ingredients harmful to the building drainage system, the public or private sewer and sewage disposal system.
152 mm
Interceptors or clarifiers for sand and similar heavy solids shall be so designed and located as to be readily accessible for cleaning and shall have a water seal of not less than _____ deep.
screening device
Every fish, fowl and animal slaughter house or establishments and every fish, fowl and meat packing or curing establishments shall drain or discharge through a __________ device and thence into a grease interceptor (clarifier) for proper disposal of effluents.
grease trap
A ______________ is not required for individual dwelling units or for any private living quarters.
3.4 liters
No individual grease trap shall be installed for a facility that has an approved rate of flow of more than _____ per second nor less than 1.3 L/s,
Flow control
__________________ devices shall be so designed that the flow through such device or devices shall at no time be greater than the rated capacity of the grease trap.
two and one-half
The total capacity of fixtures discharging into any such grease trap shall not exceed _____ times the certified liters per minute flow rate of the grease trap.
four (4)
No more than _____ separate fixture shall be connected to or discharged into one grease trap.
1.2 meters,
0.75 meters
An approved-type grease trap may be used as a fixture outlet and the grease trap for a single fixture when the horizontal distance between the fixture outlet and the grease trap does not exceed _______________ and the vertical tailpipe or drain does not exceed _______________ meters.
51 mm
Each grease trap shall have an approved water seal of not less than _____ in depth or the diameter of its outlet whichever is greater.
18 kg
Table 10-2
Grease retention capacity for 1 fixture connected with required flow rate of 76L/min
23 kg
Table 10-2
Grease retention capacity for 2 fixture connected with required flow rate of 95L/min
32 kg
Table 10-2
Grease retention capacity for 3 fixture connected with required flow rate of 132L/min
45 kg
Table 10-2
Grease retention capacity for 4 fixture connected with required flow rate of 189L/min
Number of meals per peak hour
Sizing of Grease Interceptors
NWRF = interceptor size
N stands for _____
Waste Flow Rate
Sizing of Grease Interceptors
NWRF = interceptor size
W stands for _____
Retention times
Sizing of Grease Interceptors
NWRF = interceptor size
R stands for _____
Storage Factor
Sizing of Grease Interceptors
NWRF = interceptor size
F stands for _____
6 gallon (22.7L)
Waste Flow rate with dishwashing machine
5 gallon ( 18.9L)
Waste Flow rate without dishwashing machine
2 gallon (7.6L)
Waste Flow rate for single service kitchen
1 gallon (3.8L)
Waste Flow rate with food waste disposer
2.5 hrs
Retention time for commercial kitchen waste dishwasher
1.5 hrs
Retention time for single service kitchen single serving
1
Storage Factors for Fully equipped commercial kitchen - 8hrs
2
Storage Factors for Fully equipped commercial kitchen - 16hrs
3
Storage Factors for Fully equipped commercial kitchen - 24hrs
1.5
Storage Factors for Single Service kitchen
wire basket
Laundry equipment that does not have integral strainers shall discharge into an interceptor having a _____
one
Multiple floor drains may discharge into __________ sand interceptor.
76 mm
The outlet pipe of sand interceptor shall be the same size as the inlet size of the oil interceptor, the minimum being ________ and the baffle shall have two (2) openings of the same diameter as the outlet pipe and at the same invert as the outlet pipe.
two (2)
The sand interceptor shall have an interior baffle for full separation of the interceptor into ___________ sections.
staggered
The openings of the sand interceptor shall be ______________ so that there cannot be a straight line flow between any inlet pipe and the outlet pipe.
0.2 sqm
The sand interceptor shall have a minimum dimension of ___________ for the net free opening of the inlet section.
610 mm
Minimum depth under the invert of the outlet pipe of a sand interceptor.
0.09 sqm
For each 18.9 L per minute flow or fraction thereof over 75.7 L per minute the area of the sand interceptor inlet section is to be increased by _____.
fifty (50) percent
The outlet section of sand interceptor shall at all times have a minimum area of _____ of the inlet section.