ERYTHROCYTE SEDIMENTATION RATE

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/44

encourage image

There's no tags or description

Looks like no tags are added yet.

45 Terms

1
New cards

Erythrocyte sedimentation rate (ESR)

Speed of the settiling of red blood cells in anticoagulated blood;

Measure of the distance and speed of fall in RBCs in the plasma in a tube of a standard bore and length after standing perpendiculary

2
New cards

Action of plasma proteins

Most important factor influencing ESR

3
New cards

10 minutes

Initial period of aggregation or rouleaux formation

4
New cards

40 minutes

Period of fast settling

5
New cards

10 minute

Final period of packing

6
New cards

Erythrocyte sedimentation rate

Used as an index of the presence of an active infection;

Measures the suspension stability of RBCs;

Indicates abnormal concentration of fibrinogen, globulin, and other plasma proteins

7
New cards

Wintrobe-lansberg method

Laboratory technique used to measure the ESR and to determine the PCV or hematocrit using a single specialized tube

8
New cards

0-10 mm/hr

Normal value of male using wintrobe-landsberg method

9
New cards

0-20 mm/hr

Normal value of female using wintrobe-landsberg method

10
New cards

Westergren method

Considered the most sensitive for ESR determination;

Used for the serials tudy of chronic diseases like tuberculosis, carcinoma and others

11
New cards

0-15 mm/hr

Normal value of male using westergren method

12
New cards

0-17 mm/hr

Normal value of female using westergren method

13
New cards

30 cm

Length of time in westergren

14
New cards

2.5 mm

Diameter of bore in westergren

15
New cards

Open

Bottom of tube in westergren

16
New cards

0-200 mm

Calibration in westergren

17
New cards

3.8% trisodium citrate

Anticoagulant of choice in westergren

18
New cards

11.5 cm

Length of time in wintrobe

19
New cards

3 mm

Diamted of bore in wintrobe

20
New cards

Flat and closed

Bottom of tube in wintrobe

21
New cards

0-100 mm

Calibration in wintrobe

22
New cards

Hellen and paul’s double oxalate

Anticoagulant of choice in wintrobe

23
New cards

Graphic or cutler

Anticoagulant of choice is 3% sodium citrate, uses cutler tube which has a 5 mL capacity; graduation of 0-50 mm

24
New cards

0-8 mm/hr

Normal value of male graphic or cutler

25
New cards

0-10 mm/hr

Normal value of female graphic or cutler

26
New cards

12 mm/hr

During menstruation normal value of graphic or cutler

27
New cards

3-5 mm/hr

Average normal value of male graphic or cutler

28
New cards

5-6 mm/hr

Average normal value of female graphic or cutler

29
New cards

Linzenmeier method

Anticoagulant of choice is 3% sodium citrate;

Uses Linzemmeier tube which is 65 mm in length 5 mm in diameter, and has a capacity of 1 mL

30
New cards

350-600 minutes

Normal time for male Linzenmeier method

31
New cards

300-600 minutes

Normal time for female Linzenmeier method

32
New cards

600 minutes

Normal time during menstruation of Linzenmeier method

33
New cards

Bray's method

Anticoagulant of choice is 1.3% sodium citrate;

Uses Bray’s tube which is flat-bottomed and calibrated on both sides like the wintrobe tube;

Bray’s tube can also be used for hematocrit and LE cell preparation

34
New cards

Micro landau

Anticoagulant of choice is 5% sodium citrate;

Uses a micro-landau tube which is calibrated 0-50 mm and has two graduation marks, one at 12.5 mm and another at 63.5 mm, with a small bulb similar to RBC and WBC pipettes

35
New cards

350-600 minutes

Normal value time of male in micro landau

36
New cards

1-5 mm/hr

Normal value of male in micro landau

37
New cards

1-8 mm/hr

Normal value of female in micro landau

38
New cards

1-5 mm/hr

Normal value of female during menstruation in micro landau

39
New cards

1-5 mm/hr

Normal value of children below 2 years in micro landau

40
New cards

1-8 mm/hr

Normal value of children over 2 years in micro landau

41
New cards

Smith micro

Used for infants and children when venipuncture may not be practical

42
New cards

Automated ESR system

Fully automated instrument for ESR determination

43
New cards

Mini-ves

4 samples at one time

44
New cards

Ves-matic

20 samples at one time; prints results

45
New cards

Ves-matic 60

60 samples at one time; prints results and identifies sample by a barcode reader