Mechanical: Volume Assist / Controlled
SET: Tidal volume (Vt) and RR
All breaths get the VT
Pt can have normal respiratory drive
Vent compensates for: Insufficient work of breathing
(post-surgery, sedation, paralyzed, pneumonia). NOT indicated for COPD pts
Common modes: AC/VC, V-AC, IMV, V-IMV, SIMV
Mechanica: Pressure Controlled
SET: inspiratory pressure
Some modes require Pt to have a fully functioning respiratory drive.
Vent compensates for: diminished lung compliance or atelectasis
Common modes:• P-AC, PC, PCV, PSV, CPAP
Volume: Assist Control / Volume Control (AC/VC, V-AC)
(basically the generalized stuff from flash card 1)
Set: Vt, RR, and I:E ratio
• Every breath is supported whether assisted (Pt initiated) or controlled (vent initiated) and will receive the full Vt
• Common uses: Post-op, Pneumonia, sedation, paralyzation
• Most common mode of ventilation
Volume: Volume Intermittent Mandatory Ventilation
(V-IMV, IMV, SIMV)
• Set: Vt & RR
• Pt can trigger spontaneous breaths between mandatory set breaths BUT
the Vt of the spontaneous breath will vary
• Patient must have respiratory drive; monitor RR closely and do not use NMB
medications
• Common uses: weaning and fixing WOB, resp muscles, hyperventilation has occured
Pressure: Pressure Assist/Control
(P-A/C, PC, PCV)
• Set inspiratory pressure and RR 15-25
Pressure sent during mandatory/spontaneous inspiration
• Considered a lung protective mode
• Common uses: ARDS, high PIP, noncompliant lungs
Pressure Support (PSV)
Preset inspiratory pressure BUT the patient initiates every breath and must have an adequate respiratory drive and WOB
6-12
• Common uses: weaning or in addition to other mode, reconditioning resp muscles
Continuous Positive Airway Pressure (CPAP)
-positive airway applied during expiration
BUT the patient initiates every breath and preforms all the WOB/ NEEDS RESP DRIVE
• Common uses: weaning (SBT) or OSA
• Stand alone PEEP
Hybrid: Airway Pressure Release Ventilation
(APRV)
• Set high and low pressures
• Second line use in ARDS
Hybrid: Pressure Regulated Volume Control (PRVC)
• Set Vt and RR but Pt can take spontaneous breaths.
- breaths are vent initiated OR patient initiated
-pressure during inspiration
• lowest amount of pressure to achieve set Vt from breath to breath
-monitors each breath and compares the delivered tidal volume with the set tidal volume.
-if the delivered volume is too low it increases the inspiratory pressure on the next breath.
-if it is too high it decreases the pressure
• Common uses: Post-op and Pneumonia