FDA-CDRRHR stands for?
food and drug administration - center for device regulation radiation health, and research
administrative order no 2022 - 0022:
basic radiation protection and safety standards on the use of ionizing radiation devices in planned exposure situations
for occupational exposure of workers over the age of 18:
20 mSv per year / average of 5 years (100 mSv in 5 years)
50 mSv in any single year
(occupational exposure) lens of the eye ____________
extremities - hands and feet ____________
20 mSv
500 mSv
(public exposure)
an effective dose of ________________ in a year
lens of the eye ________________
skin _______________
1 mSv
15 mSv
50 mSv
PNRI stands for?
philippine nuclear research institute
x-ray machine requirements:
machine properly installed
audible/visible indication
means to set exposure
moves smoothly
adequate x-ray room size
adequate shielding
dressing area
fixed/movable protective barrier
x-ray w/o table:
2.5 × 3 m
x-ray w table:
3.5 × 4 m
x-ray w tilting table:
4.5 × 4.5 m
transportable x-ray:
2.0m width
code of PNRI part 0
PNRI as a regulatory authority for atomic energy facilities and radioactive/nuclear materials in the philippines
code of PNRI part 02
licensing of radioactive materials and radiation facilities
code of PNRI part 03
standards for protection against radiation
code of PNRI part 04
regulation for the safe transporation of radioactive materials in the philippines
code of PNRI part 05
requirements for siting of nuclear installations
code of PNRI part 06
requirement for leadership and management for safety
code of PNRI part 07
licensing of nuclear installations
code of PNRI part 08
atomic energy facility operators licenses
dose limit for any worker over the age of 18 years:
20 mSv per year over five consecutive years and 50 mSv in any single year
dose limits and conditions for young apprentices, trainees and students:
6 mSv in a year
20 mSv eye
150 mSv skin
means the presence of a radioactive substance on a surface in quantities in excess of 0.4 Bq/cm² for beta and gamma emitters and low toxicity alpha emitters
contamination
contamination means the presence of a radioactive substance on a surface in quantities in excess of _______________ for beta and gamma emitters and low toxicity alpha emitters
0.4 Bq/cm²
types of contamination:
fixed contamination
non-fixed contamination
means contamination that can be removed from a surface during routine conditions of transport
non-fixed contamination
means contamination other than non-fixed contamination
fixed contamination
types of packages:
type A package
type B package
means a package, overpack, or freight container wherein the activity of the radioactive content shell not be greater than A1 for special form radioactive material; or A2 for all other radioactive material
type A package
means a package, overpack, or freight container wherein the activity of the radioactive content is greater than that of a type A package
type B package
means a type B package that requires multilateral approval or the approval by the relevant competent authority of the country of origin of the design or shipment and of each country through or into which the consignment is to be transported
type B (M) package
means a type B package that requires unilateral approval or an approval of a design to be given only by the competent authority of the country of origin of the design
type B (U) package
technitium-99m
A1 - 10
A2 - 4
iodine-131
A1 - 3
A2 - 0.7
means the dimensionless number assigned to a package, overpack, or freight container ot to unpackage LSA-I or SCO-I, which is used to provide control over radiation exposure during transport or storage in transit
transport index


is determined by the maximum radiation level in mSv/h at 1 meter from the external surfaces of the package, multiplied by 100
transport index
for category label, the background color of the label shall be _____________, the color of the trefoil and the printing shall be ___________, and the color of the category bar shall be ______________
white
black
red
if removable contaminations in excess of _______________ or radiation levels exceeding ___________ at the surface of the package or _______________ at 1 meter from the surface are found, the licensee shall immediately notify the final delivering carrier and the PNRI
0.4 Bq/cm²
2 mSv/h
0.1 mSv/h