1/27
Looks like no tags are added yet.
A few useable water supplies for a wildland firefighter to use as a resource are: (Page 264)
A) swimming pools, portable bladders, lakes, and ponds.
B) swimming pools, streams, lakes, and ponds.
C) dry hydrants, streams, lakes, and ponds.
D) swimming pools, streams, lakes, and riverbeds.
B) Swimming pools, streams, lakes, and ponds.
Wildland firefighters need reliable water sources to support suppression operations. Swimming pools, streams, lakes, and ponds can provide water for firefighting when they are accessible and suitable for use.
Fire crews may use pumps, hoses, or fire apparatus to move water from these sources to the fireline. They must also consider access, water availability, and environmental conditions.
A) Swimming pools, portable bladders, lakes, and ponds: Portable bladders are typically used to store water transported to an incident, rather than serving as a natural or existing water supply source in this context.
C) Dry hydrants, streams, lakes, and ponds: Dry hydrants provide access to water; they are not water sources themselves.
D) Swimming pools, streams, lakes, and riverbeds: Riverbeds may be dry and do not necessarily contain usable water.
Study Tip
Look for actual water sources. Pools, streams, lakes, and ponds can supply water; a dry hydrant is an access system, and a riverbed may be dry.
A(n) __________ is an underground water storage reservoir made of reinforced concrete. (Page 265)
A) cistern
B) dry hydrant
C) wet hydrant
D) aquifer
A) Cistern.
A cistern is a storage reservoir, often made of reinforced concrete, used to collect and store water for firefighting or other purposes.
Cisterns are especially useful in rural areas where a municipal water supply or fire hydrants may not be available.
Fire departments can access the stored water to supply fire apparatus during an emergency.
B) Dry hydrant: A pipe-and-fitting system that allows fire apparatus to draft water from a static source, such as a pond, lake, or cistern.
C) Wet hydrant: A hydrant connected to a pressurized water supply that keeps water in the hydrant barrel.
D) Aquifer: An underground layer of permeable rock or sediment that stores and transmits groundwater, not a constructed storage reservoir.
Study Tip
Cistern = stores water
dry hydrant = provides access to water.
Think of a cistern as an underground water tank firefighters can use when other water supplies aren't available.
It is common for wildland firefighters to create many improvised water sources, called __________, over the course of a fire season. (Page 265)
A) an aquifer
B) pump chances
C) a cistern
D) an improvised hydrant
B) pump chances
Pump chances are improvised water sources or locations where wildland firefighters can access water to refill their pumps and firefighting equipment during a fire. These are often established throughout a fire season to improve access to water in remote areas.
A) An aquifer: An underground layer of rock or sediment that stores and transmits groundwater.
C) A cistern: A tank or reservoir used to collect and store water.
D) An improvised hydrant: Not the specific term used in this context for the water sources described.
Study Tip
Remember: "Pump chance = a chance to pump water." Associate the term with a convenient water access point for wildland firefighters.
It is important to have an assortment of __________ on the engine for various hydrants, especially if you are responding outside of your normal area. (Page 266)
A) hard suction hoses
B) pump chances
C) hoses
D) adapters
D) Adapters
Fire engines should carry an assortment of adapters to connect hoses and equipment to different types and sizes of hydrants. This is especially important when responding outside your normal service area, where hydrant connections may differ.
A) Hard suction hoses: These are used to draft water from a static source, such as a pond or portable tank, rather than to accommodate different hydrant connections.
B) Pump chances: This is not the correct term for equipment used to connect to different hydrants.
C) Hoses: Hoses carry water, but adapters are what allow connections between incompatible fittings and sizes.
Study Tip
Adapters adapt connections! Firefighters carry different adapters to ensure their hoses and equipment can connect to various hydrants, especially in unfamiliar areas.
A __________, also called a drafting hydrant or suction pipe, is simply a pipe that is threaded on one end from which water can be pumped by the fire engine. (Page 266)
A) dry hydrant
B) drafting pipe
C) wet hydrant
D) pre-plumbed hydrant
A) Dry hydrant
A dry hydrant is a pipe system, often called a drafting hydrant or suction pipe, that allows a fire engine to draw water from a static source, such as a pond, lake, or storage tank. It is not permanently pressurized like a conventional municipal hydrant.
B) Drafting pipe: Describes a pipe used for drafting water, but it is not the specific term the question is asking for.
C) Wet hydrant: A hydrant that remains filled with water and is typically connected to a pressurized water supply.
D) Pre-plumbed hydrant: Not the standard term for a pipe used to draft water from a static source.
Study Tip
Dry hydrant = draws water from a static source.
Think of dry as meaning the pipe is not constantly filled with pressurized water. Firefighters use the engine's pump to pull water through the pipe.
Before drafting water from a dry hydrant: (Page 266)
A) pressurize the hydrant.
B) flow water into the static water source to clear debris that may be against the strainer.
C) manually clear all debris in the pipe.
D) blow out the standpipe with a Compressed Air Foam System (CAFS).
B) Flow water into the static water source to clear debris that may be against the strainer.
Before drafting water from a dry hydrant, firefighters should clear debris from the strainer to help ensure an adequate water supply. Flowing water into the static water source can help dislodge debris that may be blocking the strainer and interfering with water intake.
A) Pressurize the hydrant: A dry hydrant draws water from a static source; it is not a pressurized municipal hydrant.
C) Manually clear all debris in the pipe: Manually clearing the entire pipe is not the specific preparatory procedure described in this question.
D) Blow out the standpipe with a Compressed Air Foam System (CAFS): CAFS is used to produce and deliver compressed-air foam for firefighting, not as the standard method described for clearing a dry hydrant's strainer.
Study Tip
Dry hydrants draft; wet hydrants supply pressurized water. Before drafting, make sure the water intake and strainer are clear so debris doesn't restrict the water supply.
Portable water tanks (Port-A-Tanks) are: (Page 267)
A) commercially used fuel trucks turned into water tenders.
B) containers used as reservoirs to store water that engines can use to refill.
C) water tankers.
D) tow behind water trucks.
B) Containers used as reservoirs to store water that engines can use to refill.
Portable water tanks, commonly called Port-A-Tanks, are collapsible or foldable tanks that firefighters set up at an incident to hold water. Water tenders can fill these tanks, and fire engines can draft water from them to maintain a continuous water supply, especially in rural or wildland firefighting operations.
A) Commercially used fuel trucks turned into water tenders: Water tenders transport water, but they are not portable water tanks.
B) Containers used as reservoirs to store water that engines can use to refill: Correct! These tanks temporarily store water at the fire scene.
C) Water tankers: These are vehicles designed to transport and deliver water, not stationary portable reservoirs.
D) Tow-behind water trucks: These are mobile water-transport units, not the portable tanks themselves.
Study Tip
Port-A-Tank = stores water.
Water tender = transports water.
Fire engine = pumps water onto the fire.
Think of a Port-A-Tank as a temporary water reservoir that helps keep firefighting operations supplied!
A forestry fire hose, also called a forestry hose or soft-suction hose, is a lightweight, single-jacket, collapsible attack hose. These hoses come in 3/4-in. (19-mm), 1-in. (25.4-mm), or 1 1/2-in. (38-mm) diameters. Which of the following statements best describes forestry fire hoses? (Page 268)
A) This small diameter provides for maneuverability through brush and trees.
B) This large diameter provides excellent water supply.
C) This hose is almost always used for relay pumping.
D) This single-jacket hose provides durability and strength at high pressure.
A) This small diameter provides for maneuverability through brush and trees.
Forestry fire hoses are lightweight, flexible, and collapsible, making them ideal for wildland firefighting. Their relatively small diameters allow firefighters to carry and maneuver them through dense brush, trees, and rugged terrain.
B) This large diameter provides excellent water supply. Forestry hoses are typically small-diameter hoses designed for mobility, not large-volume water supply.
C) This hose is almost always used for relay pumping. Relay pumping uses pumps positioned in series to move water over long distances. Forestry attack hoses are primarily used to deliver water directly to the fire.
D) This single-jacket hose provides durability and strength at high pressure. Single-jacket construction helps keep the hose lightweight, but it does not provide the same level of durability and pressure resistance as many heavier-duty hose designs.
Study Tip
Forestry hose = lightweight and maneuverable. Its smaller diameter and collapsible design help firefighters move quickly through difficult wildland terrain.
A hard suction hose is: (Page 268)
A) a noncollapsible hose used to supply water to a fire pump.
B) a single-jacket hose for high pressure use.
C) a lightweight attack line.
D) used for supplying a water tender.
A) A noncollapsible hose used to supply water to a fire pump.
A hard suction hose is a rigid or semirigid, noncollapsible hose used when a fire engine drafts water from a static source, such as a pond, lake, or portable water tank. It is designed to withstand the vacuum created by the pump without collapsing.
B) A single-jacket hose for high pressure use: Single-jacket construction is associated with certain attack hoses, not hard suction hoses.
C) A lightweight attack line: Attack lines are used to deliver water directly onto a fire. Hard suction hoses draw water into the pump.
D) Used for supplying a water tender: Although hoses can be used to transfer water to a tender, hard suction hose is primarily used to draft water into a pump.
Study Tip
Hard suction = pulls water into the pump.
Hard suction hose: Draws water from a static source into the pump.
Attack hose: Carries water from the pump to the fire.
Think of hard suction as the pump's water intake line!
A hard suction hose is rigid because: (Page 268)
A) it prevents it from collapsing.
B) it needs to handle low pressure.
C) it is lightweight.
D) it needs to be distinguishable from the forestry fire hose.
A) It prevents it from collapsing.
A hard suction hose is rigid or semirigid so it can withstand the vacuum created when a fire engine drafts water from a static source. Without this rigidity, the hose could collapse under suction and interrupt the water supply.
B) It needs to handle low pressure: Hard suction hose is designed to withstand vacuum (negative pressure), not simply low water pressure.
C) It is lightweight: Hard suction hoses are generally heavier and less flexible than collapsible forestry hoses.
D) It needs to be distinguishable from the forestry fire hose: The rigidity serves a functional purpose, not merely to distinguish it from another hose type.
Study Tip
Hard suction hose holds its shape under vacuum. When a pump pulls water into the engine, the hose must resist collapsing.
Think of it as a strong intake hose that keeps the water flowing!
A crimping device used to temporarily stop the flow of water in a hose is a: (Page 269)
A) scissor clamp.
B) gated wye.
C) hose clamp.
D) gravity sock.
C) Hose clamp
A hose clamp is a crimping device used to temporarily stop or restrict water flow through a fire hose. Firefighters can use it to shut off the flow while changing hose sections or making repairs without having to shut down the entire water supply.
A) Scissor clamp: Not the standard equipment name for the device described in this question.
B) Gated wye: Splits one hose line into two separate lines and allows each outlet to be controlled with a valve.
D) Gravity sock: Not the standard tool used to crimp a fire hose and stop water flow.
Study Tip
Hose clamp = pinches the hose to stop the flow. A gated wye, on the other hand, divides one hose line into two.
There are several adapters and hose accessories; a wye is used for: (Page 271)
A) dividing a single hose line into two lines.
B) connecting hoses with different thread types.
C) attaching a smaller diameter hose to a larger diameter hose.
D) enabling water to be shut off while the pump is still running.
A) Dividing a single hose line into two lines.
A wye is a fire hose fitting that divides one incoming hose line into two outgoing hose lines. A gated wye has valves that allow firefighters to control the water flow to each outlet independently.
B) Connecting hoses with different thread types: Adapters are used to connect fittings with different thread types.
C) Attaching a smaller diameter hose to a larger diameter hose: A reducer or increaser adapter connects hoses of different diameters.
D) Enabling water to be shut off while the pump is still running: A valve or gated fitting controls water flow without requiring the pump to stop running.
Study Tip
Wye = Y-shaped, one line splits into two.
Picture the letter Y: water enters through one hose and branches into two separate hose lines. This is especially useful when firefighters need to supply multiple attack lines from one source.
A portable pump is: (Page 274)
A) a hand pump.
B) a backpack fire extinguisher.
C) a bladder bag that is fitted with straps so it can be carried to the fire.
D) a small gasoline driven pump that can be taken to a water source.
D) A small gasoline-driven pump that can be taken to a water source.
A portable pump is a small, lightweight, typically gasoline-powered pump that firefighters can transport to a water source, such as a pond, stream, or portable water tank. It allows crews to move water where a full-size fire engine cannot easily reach, especially during wildland firefighting operations.
A) A hand pump: Operated manually rather than by a gasoline-powered engine.
B) A backpack fire extinguisher: A handheld or backpack-carried firefighting tool used to spray water, not a portable powered pump.
C) A bladder bag that is fitted with straps so it can be carried to the fire: A bladder bag is a portable water container used by firefighters to apply water manually.
Study Tip
Portable pump = portable power for moving water. Unlike a bladder bag, which carries water, a portable pump actively moves water from a source to where firefighters need it.
A fire eductor pump is also called a: (Page 275)
A) jet siphon.
B) portable pump.
C) backpack fire extinguisher.
D) hand pump.
A) Jet siphon.
A fire eductor pump, also called a jet siphon, uses a pressurized stream of water to create suction that draws additional water from a source and moves it through a hose. In firefighting, eductors can help transfer water from locations where conventional drafting may be difficult.
B) Portable pump: Typically a self-contained, often gasoline-powered pump that mechanically moves water.
C) Backpack fire extinguisher: A portable container carried on the firefighter's back and used to spray water directly onto a fire.
D) Hand pump: A pump operated manually rather than using the jet action of an eductor.
Study Tip
Eductor = jet siphon. Think of a fast-moving jet of water creating suction that pulls in additional water.
A fire eductor pump uses __________ from water discharged from the pump and tank to assist moving water long distances. (Page 275)
A) gravity
B) suction
C) the venturi effect
D) the cyclone effect
C) The venturi effect.
A fire eductor pump uses the Venturi effect, in which a fast-moving stream of water creates a pressure drop that produces suction. This suction draws additional water into the flow, helping firefighters move water from a source or transfer it through a system.
A) Gravity: Gravity moves water downhill, but it does not create the pressure difference used by an eductor.
B) Suction: Suction is produced by the eductor, but the Venturi effect is the specific principle that creates it.
D) The cyclone effect: This refers to swirling or rotating flow, not the pressure principle used by an eductor.
Study Tip
Venturi = velocity creates suction. When water speeds up through a narrow passage, pressure drops, allowing the eductor to draw in more water.
A __________ is the arrangement of connected fire hose and accessories on the ground, beginning at the first pumping location and ending at the point of water delivery. (Page 278)
A) parallel setup
B) hoselay
C) staged setup
D) dual-pump
B) Hoselay
A hoselay is the arrangement of connected fire hoses and accessories used to move water from the initial pumping location to the final delivery point. In wildland firefighting, hoselays can extend over long distances to deliver water to crews working in remote areas.
A) Parallel setup: Describes an arrangement in which components operate alongside one another, not the complete hose arrangement described.
C) Staged setup: Refers to equipment or resources positioned for use, rather than the arrangement of connected hoses.
D) Dual-pump: Refers to a pumping configuration involving two pumps, not the entire hose arrangement.
Study Tip
Hoselay = the path water travels through connected hoses. Think of it as the complete hose route from the pump to the point where water is needed.
One of the advantages of a simple hoselay is that:
A) once the line is charged to the nozzle, the water needs to be shut off to extend the line.
B) high water pressures and high volumes of water can be delivered.
C) there are several lines for fire attack.
D) it's designed to quickly and continuously move water from the anchor point to the fire without shutting off the water.
B) high water pressures and high volumes of water can be delivered.
A simple hoselay can be advantageous because it allows firefighters to deliver water at high pressure and high volume, depending on the hose, pump capacity, and water supply. This helps provide an effective water stream for fire suppression.
A) Shutting off the water to extend the line is a limitation, not an advantage.
C) Multiple lines for fire attack are not the defining advantage of a simple hoselay.
D) It's designed to quickly and continuously move water from the anchor point to the fire without shutting off the water.
Study Tip
Associate a simple hoselay with effective water delivery: pressure and volume.
Progressive hoselays are often used on: (Page 279)
A) slow moving fires.
B) mop-up.
C) fast running fires.
D) easy terrain.
C) Fast running fires.
A progressive hoselay allows firefighters to extend a hose line in stages as they advance toward a fire. It is especially useful on fast-running wildland fires because crews can rapidly extend the line and establish water delivery while progressing along the fire's edge.
A) Slow moving fires: These fires generally allow more time for other hose-laying methods.
B) Mop-up: Mop-up focuses on extinguishing remaining hot spots and securing the fire perimeter, rather than rapidly extending a hose line during active fire spread.
D) Easy terrain: Terrain alone does not determine when a progressive hoselay is most useful; the method is associated with rapidly advancing hose lines.
Study Tip
Progressive = advancing forward. Progressive hoselays are useful when firefighters need to extend hose lines quickly while moving along an active fire's edge. Always follow fireline safety procedures and reassess conditions as the fire spreads.
Progressive hoselays should always start from: (Page 279)
A) an anchor point.
B) the head of the fire.
C) the engine.
D) the water source.
A) An anchor point.
A progressive hoselay should begin at a secure anchor point, such as a road, a previously established control line, or another defensible location. Starting from an anchor point helps firefighters establish a secure starting position and extend the hose line while reducing the risk of being outflanked by the fire.
B) The head of the fire: The head is typically the fastest-spreading and most dangerous part of a wildland fire, making it an unsafe starting point for establishing a hoselay.
C) The engine: An engine may be part of the water supply system, but the hoselay should be established from a secure anchor point.
D) The water source: The water source supplies water, but it is not necessarily the safest or appropriate starting point for the hose line.
Study Tip
Anchor first, advance second. An anchor point provides a secure starting location from which firefighters can extend a hose line while maintaining a safe connection to an established control feature.
An advantage of a progressive hoselay is: (Page 280)
A) the main trunk hose line can be turned off without the need of clamps.
B) it requires very little training.
C) increased friction loss.
D) more water is used with a 1-inch/25.4-mm nozzle.
A) The main trunk hose line can be turned off without the need of clamps.
A progressive hoselay allows firefighters to extend hose lines in stages as they advance along the fireline. Its configuration can allow sections of the main trunk line to be shut off as needed without requiring hose clamps, making hose operations more efficient.
B) It requires very little training: Progressive hoselays require training and coordination to establish and operate safely and efficiently.
C) Increased friction loss: Increased friction loss is a disadvantage because it reduces the water pressure available at the nozzle.
D) More water is used with a 1-inch/25.4-mm nozzle: Water consumption depends on nozzle design and operating pressure; this is not a defining advantage of a progressive hoselay.
Study Tip
Progressive hoselay = extend in stages and manage water flow efficiently. When studying its advantages, focus on how its configuration helps firefighters extend hose lines and control sections of the system.
Before a hose can be removed from a scene: (Page 281)
A) it has to be charged with water and rinsed from the inside.
B) it has to be drained of water.
C) it must be laid flat and drained.
D) it has to be washed with the nozzle.
B) It has to be drained of water.
Before fire hose is removed from a scene, it should be drained of water. Removing the water makes the hose lighter and easier to handle, transport, and store. Proper draining also helps prevent water from remaining inside the hose during transport or storage.
A) It has to be charged with water and rinsed from the inside: Charging the hose means filling it with water under pressure, which is not the required step before removal.
C) It must be laid flat and drained: Laying a hose flat is not always necessary; the essential step is draining the water.
D) It has to be washed with the nozzle: Washing may be part of hose maintenance, but it is not the specific requirement described in the question.
Study Tip
Before packing hose, drain the water. Draining makes the hose easier to handle and helps prepare it for proper cleaning, inspection, and storage.
Wet mop-up uses: (Page 282)
A) dampers and brooms.
B) back firing techniques.
C) compressed air foam.
D) water and soil together.
D) Water and soil together.
Wet mop-up is a wildland firefighting technique that uses water, often combined with soil, to extinguish remaining hot spots and prevent a fire from reigniting. Firefighters apply water to hot areas and may mix the wet soil with burning material to help cool and smother it.
Why the Others Are Incorrect
A) Dampers and brooms: These tools may be used in fire suppression, but they do not define wet mop-up.
B) Back firing techniques: Backfiring involves intentionally setting a fire to remove fuel ahead of an advancing wildfire. It is a fire control tactic, not mop-up.
C) Compressed air foam: Compressed air foam can be used in firefighting, but it is not the defining method described here.
Study Tip
Wet mop-up = water to cool, soil to smother. The goal of mop-up is to eliminate remaining heat and hot spots so the fire doesn't restart.
When using water for wet mop-up, __________ of water will allow you to be most effective. (Page 285)
A) conservation
B) no amount
C) copious amounts
D) drafting tanks
A) conservation
During wildland fire wet mop-up, firefighters must use water efficiently and conserve it because water supplies may be limited, especially in remote areas. The goal is to apply water strategically to extinguish hot spots without wasting this valuable resource.
B) No amount: Incorrect because water is useful for cooling hot spots and extinguishing burning material.
C) Copious amounts: Incorrect because using excessive amounts of water can waste a limited resource when careful, targeted application is more effective.
D) Drafting tanks: Incorrect because drafting tanks are equipment for obtaining or storing water, not a water-use strategy.
Study Tip
Remember: Mop up smart, conserve water. In wildland firefighting, use enough water to extinguish hot spots, but avoid unnecessary waste.
Exam tip: When a question emphasizes effective water use during mop-up, look for conservation rather than simply using the greatest quantity of water.
PDP stands for: (Page 285)
A) prime, dial, pump.
B) pump diameter pressure.
C) pump pressure, designated handline, primer pressure.
D) pump-discharge pressure.
D) Pump-discharge pressure.
PDP stands for Pump Discharge Pressure. It is the pressure at the pump outlet needed to deliver water through the hose and out the nozzle at the required pressure. PDP calculations account for nozzle pressure and friction loss, along with any additional factors such as elevation changes or appliance losses when applicable.
A) Prime, dial, pump: These are not the words represented by the acronym PDP.
B) Pump diameter pressure: This is not a standard firefighting term.
C) Pump pressure, designated handline, primer pressure: These words do not correctly define PDP.
Study Tip
PDP = Pump Discharge Pressure. Think of it as the pressure the pump must provide to push water through the hose and deliver it effectively at the nozzle.
__________ is the total pressure needed to overcome all friction, appliances, and elevation loss while maintaining an effective stream. (Page 285)
A) Pump pressure, designated handline, primer pressure
B) Pump diameter pressure
C) Prime, dial, pump
D) Pump-discharge pressure
D) Pump-discharge pressure
Pump-discharge pressure (PDP) is the total pressure the fire engine pump must provide to overcome friction loss, appliance loss, and elevation loss while maintaining the required nozzle pressure for an effective fire stream.
A) Pump pressure, designated handline, primer pressure: These terms do not describe the total pressure calculation in the question.
B) Pump diameter pressure: This is not a standard firefighting term for the required pump pressure.
C) Prime, dial, pump: These words do not form the correct technical term.
Study Tip
Remember this formula:
PDP=NP+FL+AL+ELPDP=NP+FL+AL+EL
NP: Nozzle pressure
FL: Friction loss
AL: Appliance loss
EL: Elevation loss
Memory trick: Think "Nozzle + Losses = PDP." When a question mentions friction, appliances, elevation, and maintaining an effective stream, look for pump-discharge pressure (PDP)
__________ is the pressure that a nozzle is designed to operate most effectively. (Page 285)
A) Pump-discharge pressure
B) Primer pressure
C) Nozzle pressure
D) Pump diameter pressure
C) Nozzle pressure
Nozzle pressure (NP) is the pressure at which a nozzle is designed to operate most effectively to produce the intended fire stream.
A) Pump-discharge pressure: The total pressure supplied by the pump to overcome nozzle pressure requirements and system losses.
B) Primer pressure: Not the correct term for the operating pressure of a nozzle.
D) Pump diameter pressure: Not a standard firefighting term for nozzle operating pressure.
Study Tip
NP = Nozzle Pressure. It refers to the pressure at the nozzle, while PDP = Pump-Discharge Pressure, which accounts for nozzle pressure plus hose and system losses.
Exam tip: If the question asks for the pressure at which a nozzle operates most effectively, choose nozzle pressure (NP).
__________ is the pressure loss from turbulence as water passes through hoses. (Page 286)
A) Nozzle reaction force
B) Friction loss
C) Coefficient
D) GPM
B) Friction loss
Friction loss (FL) is the loss of water pressure caused by friction and turbulence as water flows through fire hoses, pipes, and other components. Friction loss generally increases as flow rate increases.
A) Nozzle reaction force: The force exerted backward on the nozzle operator or hose team as water exits the nozzle.
C) Coefficient: A numerical factor used in calculations, such as determining friction loss.
D) GPM: Gallons per minute, a measurement of water flow rate, not pressure loss.
Study Tip
Friction = pressure lost while water flows.
FL = Friction loss
GPM = Gallons per minute
NP = Nozzle pressure
PDP = Pump-discharge pressure
Exam tip: If a question mentions pressure loss as water moves through a hose, the answer is usually friction loss.
PDP is a result of: (Page 286)
A) GPM.
B) the length of the hose and type of nozzle.
C) nozzle reaction force plus friction loss.
D) nozzle pressure plus friction loss.
D) nozzle pressure plus friction loss.
PDP (Pump Discharge Pressure) is the pressure a pump operator must provide at the pump to deliver the required nozzle pressure while overcoming friction loss and other pressure losses in the hose system.
A common formula is:
PDP=NP+FL+EP+Appliance Loss
Where:
NP = Nozzle pressure
FL = Friction loss in the hose
EP = Elevation pressure loss or gain
Appliance loss = Pressure loss through appliances, if applicable
A) GPM: Gallons per minute measures flow rate, not pump discharge pressure by itself.
B) The length of the hose and type of nozzle: These affect the required pressure but are not the formula for PDP.
C) Nozzle reaction force plus friction loss: Nozzle reaction is a force, not a pressure component used to calculate PDP.
Study tip
Remember: PDP = Pressure needed at the pump.