distortion

  • one of geometric properties of image quality

  • a misrepresentation of the structures

  • two types:

    • size

    • shape

  • can only be minimized


2
New cards

factors affecting size distortion

  • radiographic distances

    • magnification only

      • due to the divergent property of x-ray beam

      • minimize magnification, increase recorded detail

    • controlled by SID and OID

      • maximum SID and minimum OID

      • PA vs AP chest

      • routine is 40’’ for most studies, getting longer along with advanced technolofy

  • digital systems

    • magnification is a type of post-processing


3
New cards

SID

  • large = smaller magnification

  • small = large magnification


4
New cards

OID

  • large = large magnification

  • small = small or no magnification


5
New cards

calculating M/I/O

  • M = I/O

    • I = image size (size of object image)

    • O = object size

    • M = magnification factor/ratio

  • M = 1 ; no magnification

  • M > 1; image is greater than object


6
New cards

calculating size distortion

  • magnification factor:

    • M = SID/SOD

    • M = I/O

    • M = I/O = SID/SOD


7
New cards

optimizing image quality

  • size of image(I) = size of object(O) x M

  • size of image(I) = size of object(O) x SID/SOD

  • minimize magnification

    • minimize OID

    • maximize SID


8
New cards

calculating object size

  • size of image (I) = size of object (O) x SID/SOD

  • (I - O)/O x 100% = percent of M of the object


9
New cards

factors affecting shape distortion

  • the misrepresentation by unequal magnification of actual structures

  • what causes it:

    • wrong relationship between CR, body part, and IR

    • incorrect centering — off-centering the tube, incorrect centering body part, off-centering the IR

  • two types:

    • elongation

    • foreshortening

  • alignment:

    • central ray, anatomical part, image receptor

  • to minimize:

    • CR perpendicular to IR; part parallel to IR

    • sometimes, angle is necessary

    • CR: further away from center, more distortion

  • evaluation is very subjective


10
New cards

elongation

tube/receptor is improperly aligned

11
New cards

foreshortening

only when part is improperly aligned

12
New cards

angulation

  • away from perpendicular to the IR

    • degree

    • direction

    • controls how much distortion to avoid superimposition

    • changes the SID

      • more angle (thicker body part), the longer SID

        • will affect IR exposure if not compensated

        • to compensate, decrease SID (lower tube) or increase mAs


13
New cards

degree

  • how much angulation — how much distortion

  • the angle between CR and IR


14
New cards

direction

caudal or cephalic

15
New cards

effects on image appearance

  • size

    • magnification

    • always involves a degree of loss of resolution

  • shape

    • both elongation and foreshortening

    • can be utilized sometimes