interface
material between socket & pt skin
purpose: suspension, skin protection, adjust socket fit (esp if RL vlume fluctuates)
socket may be rigid or flexible
goals of suspension
little to no mvmt btwn RL and socket
comfort w/o skin breakdown or irritation
no interference w/ knee flex in sitting (TT)
prosthetic remains secure for all of pt activities
suspension may be primary or ancillary (added for <security)
PTB socket
ant wall: pry WB, bisects patella and w/ indented “patellar tendon bar”
med/lat walls: knee stability, rise above proximal pole of patella
post wall: push RL onto ant wall—room for hamstring tendons, med side lower than lat
long RL: shorter post wall for full KF ROM
short RL: higher post wall to retain soft tissue in socket

total surface bearing
shape in transverse plane reflects cross section of limb (typically round)
fits snugly to disperse forces across all surfaces
gel liners help reduce shear, improve comfort
many current prostehtics in hybrid shape

transtibial suspension types
pin-lock
suction
sleeve
elevated vacuum
supracondylar, suprapatellar
cuff & waist belt/strap
pin lock suspension
most common form of TT suspension
silicone liner w/ attached distal pin
pin slides into hole in distal socket, locks in place
ridges on pin make audible “click”
fit can be adjusted w/ adding/removing socks
release w/ button on exterior of socket
mechanisms wear out over time
suction suspension
silicone liner seals into place, generates suction force between RL and socket
may have expulsion valve to continuously remove air, maintain - psi
more common in TF amputees
sleeve suspension
combo of silicone liner & ext sleeve made of latex/neoprene/similar
airtight seal btwn sleeve & liner
good cosmesis, min impact on KF
can be hot (incr perspiration, fit issues, skin irritation)
easily damaged, expensive to replace
liner & sleeve may be difficult for pts w/ UE dysfunction to don/doff properly
elevated vacuum
electric or manual/mechanical pump generates continuous - psi
works best w/ TSB socket
requires liner & sealing sleeve
supracondylar & suprapatellar suspension
proximal brim of socket extends over patella, medial & lateral femoral condyles
uses flexible inner socket made of foam
encourages slight KF
transtibial socket design
2 pry designs: PTB, TSB
both reduce WB through distal end of RL
PTB loads psi tolerant areas, TSB disperses psi across large surface area
off-load zones (psi intolerant)
sharp bony prominences: fib head, cut end of fib, tibial tubercle, tibial crest, patella
load zones (psi tolerant)
muscle bellies, broad/flat areas of bone & soft tissue: patellar tendon, ant tibial muscles, post muscles, femoral condyles, medial tibial flare, tibial shaft
sagittal plane alignment
modulates forces of WB & ant/post knee stability
socket is ~5 deg of flexion (prox end tilted ant compared to distal)=slight DF & KF, extra socket flexion needed to accommodate KF contracture
prostehtic foot position set based on heel height of shoe
change of footwear, inappropriate heel cushion stiffness→impacted KF/KE moment in stance
frontal plane alignment
modulates forces of WB & med/lat stability
socket in ~5 deg adduction
prosthetic foot directy under socket: vertical line transects heel, may be inset <½“
inset or outset impacts forces on RL (varus/valgus), comfort, energy cost
inset foot position impact
foot placed more medially on socket
varus force thru knee during stance
incr loading thru prox-med and distal-lat socket
can cause gapping of prox-lat socket, but also reduces pressure on fibular head
outset foot position impacts
foot placed more laterally on socket
valgus force thru knee during stance
incr loading thru distal-med & prox-lat socket
wider BOS
less energy efficient, may reduce pain & improve comfort for pts with short RL
transfemoral socket design
ischial containment, marlo anatomical socket, quadrilateral, subischial (L→R)

quadrilateral socket
square/rectangle shape
med-lat dimension bigger than ant-post
higher ant/lat wall: better stability, forces→post
post shelf: WB thru ischial tub & glutes
med wall: concavity to relieve add longus tendon
lateral wall: concavity to relieve greater troch
ischial containment socket
ischial tub & pubic ramus sit w/in socket
ant-post dimension larger & provides room for mm contract
high med walls limit lat displacement & mimics natural add angle of femur
TF socket considerations
limited evidence in research to guide decision making
general strategies: ischial containment for short, weak RL w/ lots of soft tissue/little muscle, quadrilateral for long/firm/strong RL, subischial for greater amount of hip ROM
quad socket: good AP stability in sagittal, limited ability to prevent femur from lateral drifting
ischial containment: forces directed sup & med to keep femur in add position & maintain level pelvis
TF alignment sagittal
mechanical knee jt needs to be ext in stance
CL step length should be normal
5 deg flexion in socket or 5 extra if pt has contracture: elongates hip ext to improve contractile force, reduces tendency to compensate for weak hip ext w/ lumbar lordosis
TF alignment frontal
socket fabricated in 5-7 deg of add
establishes normal angle of femur
lat wall of socket→med directed force for stability
elongate fibers of glute med to improve contractile force
foot position: plumb line from ischial tub should bisect heel; inset bc narrow BOS more energy efficient
sagittal plane factors impairing stability
weak hip exts, short RL, hip flex contracture, higher heel on shoe, knee unit set ant to wt line
frontal plane factors impairing stability
weak hip abd, short RL, hip abd contracture
transfemoral suspension
traditional pull-in suction
roll-on liners
total elastic suspension
silesian belt
pelvic belt
osseointegration
pull-in suction
req snuf prox fit, distal air expulsion valve to maintain - air psi, no air entry
don: liquid power/pull sock
benefits: comfort, cosmesis, good proprioception & prosthetic control
drawbacks: not for recent amp/fluctuating volume, high shear during donning, not good for fragile skin/scars/trigger points/adhesions, req good strength & control in RL and UEs
roll on liners
similar to use in transtibial prosthetics
liners made from silicone, urethane
distal air expulsion valve; suction maintained btwn liner & socket
benefits: easy to don/doff; liner contains soft tissue; can be used for short RL or limbs w/ scar/adhesions
drawbacks: liners not durable, must be replaced often; hygiene concerns
variations: pin lock, lanyard, elevated vacuum
total elastic suspension
elastic neoprene
distal sleeve attaches to socket & waist belt holds in place
may be used as sec suspension for athletes
benefits: appropriate for recent amp, OAs unable to use traditional suction/liners, pt with tender skin or adhesions
drawbacks: hot, unable to control RL rotation w/in socket
silesian belt
harness attaches to lat socket
belt wraps around waist/trunk
buckles on ant socket
benefits: relatively easy & lightweight
drawbacks: unable to fully control RL rotation w/in socket
pelvic belt
rigid single axis hip jt just sup/ant to greater troch
improve med-lat stability of prosthesis, reduce rotation
benefits: helpful for short RL; used pry w/ quad socket
drawbacks: heavy, longer fabrication time, uncomfy in sitting, maintenance, noise
osseointegration
surgically implanted metal pin connects direct to prostehsis w/o need for socket
benefits: No pistoning, direct WB thru femur, lightweight
pts req fewer prosthesis appointments for adjustment
drawbacks: complications range from mild infection to osteomyelitis, need for removal, possible bone loss or more prox amputation
in case of fall→incr forces thru femur
TF prosthetic goals
knee stability in stance phase
KF to ensure foot clearance in swing phase
smooth transitions btwn stance & swing
constant contact btwn socket & RL
min gait deviations=reduce energy cost w/ amb