Assist control (AC)
preset rate and tidal volume, client initiates breath and ventilator takes over for the intubated client
hyperventilation can result in respiratory alkalosis
client can require sedation to decrease respiratory rate
Synchronized Intermittent Mandatory Ventilation (SIMV)
preset rate and tidal volume for machine breaths
client initiates breath and tidal volume will depend upon client’s effort
ventilator initiated breaths are synchronized to reduce competition between ventilator and client
used as a regular mode of ventilation or a weaning mode
can increase WOB causing respiratory muscles to fatigue
Inverse ventilation ratio (IVR)
allows alveolar gas to be expelled by the lungs own natural recoil
time-triggered and pressure-limited
breaths can be initiated spontaneously or by the ventilator
causes less ventilator-induced lung injury and fewer adverse effects on the cardiovascular system
airway pressure release ventilation (APRV)
double-lumen ET tube allows ventilation of each lung separately
used for clients who have unilateral lung disease
requires two ventilators, sedation, and/or neuromuscular blocking agents
Positive end expiratory pressure (PEEP)
preset pressure delivered during expiration
added to prescribed ventilator settings to treat persistent hypoxemia
improves oxygenation by enhancing gas exchange and preventing atelectasis
amount of PEEP added is typically 5-15 cm H2O
pressure support ventilation (PSV)
works to keep the alveoli from collapsing during expiration
allows for greater oxygenation and makes the work of breathing easier
allows for lower levels of FiO2 to be used
can be used with IMV or AC modes to treat or prevent atelectasis
settings 5-20 mmHg
Continuous positive airway pressure (CPAP)
positive pressure supplied during spontaneous breathing
no ventilator breaths delivered unless conjunction with SIMV
risks include volutrauma, decreased CO and ICP
Volume (low pressure) alarm
alarm
indicate a low exhaled volume due to a disconnection, cuff leak, and or tube displacement
pressure (high pressure) alarms
alarm
indicates excess secretions, client biting the tubing, kinks in the tubing, client coughing, pulmonary edema, bronchospasm, or pneumothorax
Apnea alarms
alarm
indicate that the ventilator does not detect spontaneous respiration in a preset time period
20-25 mmHg
what is the goal for the cuff pressure?
every 12 hours
how often should the ET tube be repositioned?
every 8 hours
how often should oral care be preformed?
blood pressure or HR changes by more than 20%
during the weaning phase, what are changes to the vital signs that show that the patient is not doing well?
fluid rentention
patients on a ventilator are at risk for what fluid imbalance?