Day 34 — Digital Thermometer Calibration
Day 34 — Digital Thermometer Calibration
0.0
(0)
Rate it
Studied by 0 people
Call Kai
Learn
Practice Test
Spaced Repetition
Match
Flashcards
Knowt Play
Card Sorting
1/45
There's no tags or description
Looks like no tags are added yet.
46 Terms
View all (46)
Star these 46
1
New cards
What is the title of the Day 34 calibration infographic?
Digital Thermometer Calibration[cite: 13
2
New cards
What core subtitle or topic basis is covered in Day 34?
Manufacturer specification and applicable method[cite: 13
3
New cards
What learning journey series does Day 34 belong to?
Continuing my 90-Day Calibration Learning Journey Beginner to Calibration Specialist 2026[cite: 13
4
New cards
What is a digital thermometer?
A temperature instrument that displays a numerical reading and may include RTD/PRT
5
New cards
What must be identified first when starting with the specification?
Make
6
New cards
What parameters should be confirmed regarding range and display in specifications?
Measurement range and display resolution[cite: 14]
7
New cards
What should be checked regarding accuracy or permissible error?
The accuracy or permissible-error statement and its conditions[cite: 14]
8
New cards
What compatibility must be confirmed before calibration?
Probe and indicator compatibility[cite: 14]
9
New cards
How should calibration points be selected?
From intended use
10
New cards
What vital warning is given about resolution in specifications?
Resolution is not the same as accuracy[cite: 14]
11
New cards
What equipment is required in the calibration setup?
A suitable calibrated reference
12
New cards
What must be allowed during the calibration setup measurements?
Readings to stabilize following approved method and manufacturer instructions[cite: 14]
13
New cards
What formula defines indication error in the measurement model?
E equals IDUT minus Tref[cite: 13
14
New cards
What formula defines correction in the measurement model?
C equals negative E[cite: 13
15
New cards
What does E represent in the measurement model?
Indication error[cite: 13
16
New cards
What does IDUT represent in the measurement model?
DUT indication[cite: 14]
17
New cards
What does Tref represent in the measurement model?
Reference temperature[cite: 14]
18
New cards
What does C represent in the measurement model?
Correction[cite: 14]
19
New cards
What relationship exists between correction and error?
Correction and error have opposite signs[cite: 13
20
New cards
What is step one of the calibration workflow?
Review request
21
New cards
What is step two of the calibration workflow?
Identify instrument and probe[cite: 14]
22
New cards
What is step three of the calibration workflow?
Inspect condition
23
New cards
What is step four of the calibration workflow?
Verify reference and temperature source[cite: 14]
24
New cards
What is step five of the calibration workflow?
Select calibration points as applicable[cite: 14]
25
New cards
What is step six of the calibration workflow?
Stabilize at each point by allowing time[cite: 14]
26
New cards
What is step seven of the calibration workflow?
Record readings for reference and DUT[cite: 14]
27
New cards
What is step eight of the calibration workflow?
Calculate error and correction[cite: 14]
28
New cards
What is step nine of the calibration workflow?
Evaluate uncertainty[cite: 14]
29
New cards
What is step ten of the calibration workflow?
Report results including uncertainty
30
New cards
What reference temperature and DUT indication are used in the worked example?
Reference temperature is 100.00 degrees Celsius and DUT indication is 100.30 degrees Celsius[cite: 13
31
New cards
What are the calculated error and correction values in the worked example?
Error is +0.30 degrees Celsius and correction is -0.30 degrees Celsius[cite: 13
32
New cards
What important note is attached to the worked example?
One point does not establish overall accuracy or pass/fail[cite: 13
33
New cards
What uncertainty contributors are listed for digital thermometer calibration?
Reference calibration
34
New cards
What must be reported when presenting reporting and conformity data?
Report indication
35
New cards
When can pass/fail statements be provided?
Only when applicable specification/tolerance and documented decision rule are established[cite: 14]
36
New cards
What common mistakes are listed in panel nine?
Confusing resolution with accuracy
37
New cards
What core metrology principles are highlighted in the bottom banner of panel nine?
Accuracy does not equal resolution
38
New cards
What is the technical question in the calibration challenge?
At reference 50.00 degrees Celsius and DUT reads 50.20 degrees Celsius
39
New cards
What is the answer to the technical question in the challenge?
Error equals +0.20 degrees Celsius and correction equals -0.20 degrees Celsius[cite: 13
40
New cards
What is the witty question in the calibration challenge?
If the display shows more digits
41
New cards
What is the answer to the witty challenge question?
No
42
New cards
What is the practical question in the calibration challenge?
Readings drift at a calibration point
43
New cards
what would you check and document?[cite: 13
14]
44
New cards
What is the suggested response to the practical challenge question?
Check temperature-source stability
45
New cards
What key references are cited for Day 34?
NIST/NC SOP 25 2021
46
New cards
What is the core practical takeaway for Day 34?
Follow actual manufacturer specification and approved method