Second Law of Thermodynamics and Entropy

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/25

flashcard set

Earn XP

Description and Tags

Vocabulary practice cards covering the Second Law of Thermodynamics, the Rankine cycle, refrigeration plants, heat pumps, performance metrics (COP and SCOP), and entropy balances for closed and open systems based on Introduction to Engineering Thermodynamics by Claire Yu Yan.

26 Terms

1
New cards

Heat engine

A device or system that converts thermal energy (heat) into mechanical work by absorbing heat from a high-temperature source, converting part of that heat into work, and releasing the remaining heat to a low-temperature sink.

2
New cards

Working substance

A gas or liquid in a heat engine that absorbs heat, expands, and performs mechanical work (such as steam in a steam turbine).

3
New cards

Heat sink

A low-temperature body or reservoir where leftover heat from a heat engine is expelled (such as the condenser in a steam turbine system).

4
New cards

Rankine cycle

The ideal thermodynamic cycle used in steam power plants to convert heat into mechanical work, typically using water as the working fluid.

5
New cards

Isentropic compression (Rankine cycle)

The process in a Rankine cycle where a pump pressurizes liquid water from a low pressure to a high pressure without change in entropy.

6
New cards

Isobaric heat addition (Rankine cycle)

The process where high-pressure liquid water is heated in a boiler at constant pressure, converting it into a superheated vapor or steam.

7
New cards

Isentropic expansion (Rankine cycle)

The process where high-pressure, high-temperature steam expands through a turbine at constant entropy, driving a generator to produce work.

8
New cards

Isobaric heat rejection (Rankine cycle)

The process in which exhaust steam from the turbine is cooled and condensed back into liquid at constant pressure inside a condenser.

9
New cards
<p>$$T\text{-}s$$ diagram of a Rankine cycle</p>

T-sT\text{-}s diagram of a Rankine cycle

A thermodynamic property diagram plotting temperature (∘C^{\circ}\text{C}) against specific entropy (kJ/(kg⋅K)\text{kJ}/(\text{kg}\cdot\text{K})), demonstrating the cycle processes across the vapor dome between a high boiler pressure (such as 50 bar50\,\text{bar} / 725 psi725\,\text{psi}) and a low condenser pressure (such as 0.06 bar0.06\,\text{bar} / 0.87 psi0.87\,\text{psi}).

10
New cards

Entropy

A measure of the disorder of a system representing energy that is unavailable to do work.

11
New cards

Net work output (W˙net,out\dot{W}_{net, out})

The net rate of mechanical work delivered by a heat engine, calculated as: Q˙H−Q˙L=W˙turbine−W˙pump=W˙net,out\dot{Q}_H - \dot{Q}_L = \dot{W}_{turbine} - \dot{W}_{pump} = \dot{W}_{net, out} where Q˙H\dot{Q}_H is heat absorbed from the heat source and Q˙L\dot{Q}_L is heat rejected to the heat sink in kW\text{kW}.

12
New cards

Thermal efficiency (ηth\eta_{th})

A dimensionless measure of heat engine performance defined by: ηth=desired outputrequired input=W˙net,outQ˙H=1−Q˙LQ˙H\eta_{th} = \frac{\text{desired output}}{\text{required input}} = \frac{\dot{W}_{net, out}}{\dot{Q}_H} = 1 - \frac{\dot{Q}_L}{\dot{Q}_H}.

13
New cards

Refrigeration plant

A system that absorbs heat from a low-temperature heat sink and rejects heat to a high-temperature heat source by consuming mechanical work, using a refrigerant that undergoes phase changes.

14
New cards
<p>Vapor compression refrigeration cycle</p>

Vapor compression refrigeration cycle

A refrigeration cycle consisting of four principal components: a compressor, a condenser, an expansion device, and an evaporator, operating across high-pressure and low-pressure sides to transfer heat.

15
New cards

Work requirement in refrigeration

The external work input (W˙in=Q˙H−Q˙L\dot{W}_{in} = \dot{Q}_H - \dot{Q}_L) that must be supplied because heat cannot spontaneously flow from a low-temperature body to a high-temperature body by itself.

16
New cards

Coefficient of performance (COP)

A measure of how efficiently a refrigerator or heat pump operates, defined as: COP=Useful Energy OutputWork or Energy Input\text{COP} = \frac{\text{Useful Energy Output}}{\text{Work or Energy Input}}, indicating how many units of heating or cooling are gained per unit of energy consumed.

17
New cards

Coefficient of performance of a refrigerator (COPR\text{COP}_R)

The ratio measuring cooling performance per unit power consumption: COPR=desired outputrequired input=Q˙LW˙in=Q˙LQ˙H−Q˙L=1(Q˙H/Q˙L)−1\text{COP}_R = \frac{\text{desired output}}{\text{required input}} = \frac{\dot{Q}_L}{\dot{W}_{in}} = \frac{\dot{Q}_L}{\dot{Q}_H - \dot{Q}_L} = \frac{1}{(\dot{Q}_H / \dot{Q}_L) - 1} (typical split AC/heat units range from 3.03.0 to 5.05.0).

18
New cards

Heat pump

A device utilizing the vapor compression cycle whose main purpose is to supply heat (Q˙H\dot{Q}_H) to a high-temperature heat source (such as indoor air) by absorbing heat (Q˙L\dot{Q}_L) from a low-temperature heat sink (such as winter outdoor air) through work input.

19
New cards

Coefficient of performance of a heat pump (COPHP\text{COP}_{HP})

The efficiency ratio evaluating heat supplied per unit work consumed: COPHP=desired outputrequired input=Q˙HW˙in=Q˙HQ˙H−Q˙L=Q˙H/Q˙L(Q˙H/Q˙L)−1\text{COP}_{HP} = \frac{\text{desired output}}{\text{required input}} = \frac{\dot{Q}_H}{\dot{W}_{in}} = \frac{\dot{Q}_H}{\dot{Q}_H - \dot{Q}_L} = \frac{\dot{Q}_H / \dot{Q}_L}{(\dot{Q}_H / \dot{Q}_L) - 1}.

20
New cards

Seasonal Coefficient of Performance (SCOP)

A metric measuring how efficiently a heat pump or air conditioner operates over an entire heating season rather than at a single test point, accounting for seasonal temperature changes, defrost cycles, and part-load operations.

21
New cards

Closed system (control mass)

A thermodynamic system with a fixed quantity of mass where energy (heat or work) may cross the system boundary, but no mass is permitted to cross.

22
New cards
<p>Closed system entropy transfer mechanism</p>

Closed system entropy transfer mechanism

The transfer of entropy across a closed system boundary via heat transfer (+Q1T1+\frac{Q_1}{T_1} in and −Q2T2-\frac{Q_2}{T_2} out), while entropy generation satisfies Sgen≥0S_{gen} \ge 0 and work transfers zero entropy.

23
New cards

Open system (control volume)

A thermodynamic region in space that can exchange mass, energy, and entropy across its system boundary with the surroundings.

24
New cards

Time rate of entropy transfer due to heat transfer (S˙heat\dot{S}_{heat})

The rate at which entropy is transferred into or out of a boundary via heat transfer: S˙heat=dSheatdt≅∑Q˙kTk\dot{S}_{heat} = \frac{dS_{heat}}{dt} \cong \sum \frac{\dot{Q}_k}{T_k} where Q˙k\dot{Q}_k is the heat transfer rate at location kk and TkT_k is the boundary temperature in Kelvin.

25
New cards

Time rate of entropy transfer accompanying mass transfer (S˙mass\dot{S}_{mass})

The rate at which entropy is carried across a control surface by fluid flow: S˙mass=∑dSmassdt=∑m˙ksk\dot{S}_{mass} = \sum \frac{dS_{mass}}{dt} = \sum \dot{m}_k s_k where m˙k\dot{m}_k is the mass flow rate and sks_k is the specific entropy of the fluid.

26
New cards
<p>Control volume entropy balance</p>

Control volume entropy balance

The second law formulation for an open system stating that the rate of entropy accumulation (dSc.v.dt\frac{dS_{c.v.}}{dt}) equals the net entropy transfer rate via heat (Q˙c.v.\dot{Q}_{c.v.}) and mass flow (m˙isi−m˙ese\dot{m}_i s_i - \dot{m}_e s_e) plus the internal rate of entropy generation (S˙gen\dot{S}_{gen}).