1/25
Vocabulary practice cards covering the Second Law of Thermodynamics, the Rankine cycle, refrigeration plants, heat pumps, performance metrics (COP and SCOP), and entropy balances for closed and open systems based on Introduction to Engineering Thermodynamics by Claire Yu Yan.
Heat engine
A device or system that converts thermal energy (heat) into mechanical work by absorbing heat from a high-temperature source, converting part of that heat into work, and releasing the remaining heat to a low-temperature sink.
Working substance
A gas or liquid in a heat engine that absorbs heat, expands, and performs mechanical work (such as steam in a steam turbine).
Heat sink
A low-temperature body or reservoir where leftover heat from a heat engine is expelled (such as the condenser in a steam turbine system).
Rankine cycle
The ideal thermodynamic cycle used in steam power plants to convert heat into mechanical work, typically using water as the working fluid.
Isentropic compression (Rankine cycle)
The process in a Rankine cycle where a pump pressurizes liquid water from a low pressure to a high pressure without change in entropy.
Isobaric heat addition (Rankine cycle)
The process where high-pressure liquid water is heated in a boiler at constant pressure, converting it into a superheated vapor or steam.
Isentropic expansion (Rankine cycle)
The process where high-pressure, high-temperature steam expands through a turbine at constant entropy, driving a generator to produce work.
Isobaric heat rejection (Rankine cycle)
The process in which exhaust steam from the turbine is cooled and condensed back into liquid at constant pressure inside a condenser.

T-s diagram of a Rankine cycle
A thermodynamic property diagram plotting temperature (∘C) against specific entropy (kJ/(kg⋅K)), demonstrating the cycle processes across the vapor dome between a high boiler pressure (such as 50bar / 725psi) and a low condenser pressure (such as 0.06bar / 0.87psi).
Entropy
A measure of the disorder of a system representing energy that is unavailable to do work.
Net work output (W˙net,out)
The net rate of mechanical work delivered by a heat engine, calculated as: Q˙H−Q˙L=W˙turbine−W˙pump=W˙net,out where Q˙H is heat absorbed from the heat source and Q˙L is heat rejected to the heat sink in kW.
Thermal efficiency (ηth)
A dimensionless measure of heat engine performance defined by: ηth=required inputdesired output=Q˙HW˙net,out=1−Q˙HQ˙L.
Refrigeration plant
A system that absorbs heat from a low-temperature heat sink and rejects heat to a high-temperature heat source by consuming mechanical work, using a refrigerant that undergoes phase changes.

Vapor compression refrigeration cycle
A refrigeration cycle consisting of four principal components: a compressor, a condenser, an expansion device, and an evaporator, operating across high-pressure and low-pressure sides to transfer heat.
Work requirement in refrigeration
The external work input (W˙in=Q˙H−Q˙L) that must be supplied because heat cannot spontaneously flow from a low-temperature body to a high-temperature body by itself.
Coefficient of performance (COP)
A measure of how efficiently a refrigerator or heat pump operates, defined as: COP=Work or Energy InputUseful Energy Output, indicating how many units of heating or cooling are gained per unit of energy consumed.
Coefficient of performance of a refrigerator (COPR)
The ratio measuring cooling performance per unit power consumption: COPR=required inputdesired output=W˙inQ˙L=Q˙H−Q˙LQ˙L=(Q˙H/Q˙L)−11 (typical split AC/heat units range from 3.0 to 5.0).
Heat pump
A device utilizing the vapor compression cycle whose main purpose is to supply heat (Q˙H) to a high-temperature heat source (such as indoor air) by absorbing heat (Q˙L) from a low-temperature heat sink (such as winter outdoor air) through work input.
Coefficient of performance of a heat pump (COPHP)
The efficiency ratio evaluating heat supplied per unit work consumed: COPHP=required inputdesired output=W˙inQ˙H=Q˙H−Q˙LQ˙H=(Q˙H/Q˙L)−1Q˙H/Q˙L.
Seasonal Coefficient of Performance (SCOP)
A metric measuring how efficiently a heat pump or air conditioner operates over an entire heating season rather than at a single test point, accounting for seasonal temperature changes, defrost cycles, and part-load operations.
Closed system (control mass)
A thermodynamic system with a fixed quantity of mass where energy (heat or work) may cross the system boundary, but no mass is permitted to cross.

Closed system entropy transfer mechanism
The transfer of entropy across a closed system boundary via heat transfer (+T1Q1 in and −T2Q2 out), while entropy generation satisfies Sgen≥0 and work transfers zero entropy.
Open system (control volume)
A thermodynamic region in space that can exchange mass, energy, and entropy across its system boundary with the surroundings.
Time rate of entropy transfer due to heat transfer (S˙heat)
The rate at which entropy is transferred into or out of a boundary via heat transfer: S˙heat=dtdSheat≅∑TkQ˙k where Q˙k is the heat transfer rate at location k and Tk is the boundary temperature in Kelvin.
Time rate of entropy transfer accompanying mass transfer (S˙mass)
The rate at which entropy is carried across a control surface by fluid flow: S˙mass=∑dtdSmass=∑m˙ksk where m˙k is the mass flow rate and sk is the specific entropy of the fluid.

Control volume entropy balance
The second law formulation for an open system stating that the rate of entropy accumulation (dtdSc.v.) equals the net entropy transfer rate via heat (Q˙c.v.) and mass flow (m˙isi−m˙ese) plus the internal rate of entropy generation (S˙gen).