b
A) A probe or an explorer should be applied to the teeth and gingiva before an initial review of information from the patient history has been made. B) Cassette setups for all patients need a basic setup composed of a mouth mirror, probes to include furcation probe, and explorers to include a subgingival explorer.
a. Statement A is true and statement B is false.
b. Statement A is false and statement B is true.
c. Both statements are true.
d. Both statements are false.
d
The shepherd's hook explorer is commonly used for examining:
a) proximal surfaces.
b) margins of restorations.
c) concave areas.
d) pits and fissures.
a
Why would a dental hygienist dry supragingival calculus with an air syringe?
a) To facilitate exploring and scaling
b) To deflect the gingival margin
c) To identify areas of demineralization
d) To recognize location and condition of restorations
d
A sulcus and pocket survey should consist of all of the following, except:
a) examine the shape and dimensions of sulci and pockets.
b) measure and record probing depths.
c) evaluate tooth surface pocket wall.
d) chart plaque and severity.
b
A) A probe is a slender instrument with a rough, pointed tip designed for examination of the depth and topography of a gingival sulcus or periodontal pocket. B) A probe has three parts: the handle, the angled shank, and the working end.
a. Both statements are true.
b. Statement A is false and statement B is true.
c. Statement A is true and statement B is false.
d. Both statements are false.
b
A pocket is:
a) healthy gingival sulcus
b) diseased gingival sulcus
c) a calculus deposit
d) a plaque deposit
d
All of the following are factors that affect probe determinations except:
a) accuracy and consistency
b) patient discomfort and trauma to the tissues must be minimal
c) severity and extent of periodontal disease
d) patient age
a
The probe is at the base of the sulcus or crevice, at the coronal end of the junctional epithelium with normal healthy tissue. The probe tip is within the junctional epithelium with advanced periodontitis.
a. Statement A is true and statement B is false.
b. Statement A is false and statement B is true.
c.Both statements are true.
d. Both statements are false.
d
The following are all possible problems when placing the probe, except:
a) anatomic variations.
b) interferences.
c) accessibility.
d) firm gingiva.
a
Where is the measurement of the probing depth made?
a) From the gingival margin to the attached periodontal tissue
b) From the gingival margin to the base of the alveolar ridge
c) From the gingival margin to the bottom of the periodontal ridge
d) From the gingival margin through the col area
b
The technique used with the periodontal probe is:
a) running stroke.
b) walking stroke.
c) jogging stroke.
d) sliding stroke.
c
A) With molars and premolars, the probe is oriented at the distal line angle for both facial and lingual application. B) With anterior teeth, the initial insertion may be at the distal line angle or from the midline of the facial or lingual surfaces.
a. Statement A is true and statement B is false.
b. Statement A is false and statement B is true.
c. Both statements are true.
d. Both statements are false.
b
The clinical attachment level refers to the position of the:
a) gingiva surrounding the teeth.
b) periodontal attached tissues at the base of a sulcus.
c) gingival attachment apparatus.
d) alveolar bone in correlation to gingival attachment.
d
All of the following are purposes of the tension test conducted during a mucogingival examination, except:
a) to detect adequacy of the width of the attached gingiva.
b) to locate frenal attachments and their proximity to the free gingiva.
c) to identify promptly the mucogingival junction.
d) to determine when a pocket extends to or beyond the col area.
a
The working end of an explorer is a __________ that is circular in cross section and tapers to a fine sharp point.
a) slender, wirelike, metal tip
b) thick, stringlike, metal tip
c) slender, flosslike, plastic tip
d) thick, wirelike, plastic tip
c
A) A single-ended instrument has one working end on a separate handle. B) A double-ended instrument has two working ends, one on each end of a common handle.
a. Statement A is true and statement B is false.
b. Statement A is false and statement B is true.
c. Both statements are true.
d. Both statements are false.
d
All of the following are types of explorers, except:
a) ODU 11/12, TU-17.
b) shepherd's hook.
c) pigtail or cowhorn.
d) H 6/7.
d
A) Supragingival calculus is most commonly found on the facial surfaces of the mandibular anterior teeth and lingual surfaces of the maxillary first and second molars. B) Subgingival calculus is typically not localized.
a. Statement A is true and statement B is false.
b. Statement A is false and statement B is true.
c. Both statements are true.
d. Both statements are false.
b
A) The periodontal ligament is connective tissue and appears radiopaque in a radiograph. B) Early furcation involvement may appear as a small radiolucent black area.
a. Statement A is true and statement B is false.
b. Statement A is false and statement B is true.
c. Both statements are true.
d. Both statements are false.
a
A) Some proximal overhanging margins may be seen on radiographs. B) The use of an explorer is unnecessary to detect irregular margins and to examine all proximal margins that do not reveal irregularities in the radiographs.
a. Statement A is true and statement B is false.
b. Statement A is false and statement B is true.
c. Both statements are true.
d. Both statements are false.
b
With the explorer tip sharp and tapered, the following can be expected, except:
a) increased tactile sensitivity with less pressure required.
b) some necessary trauma to the gingival tissue.
c) decreased instrumentation time with increased patient comfort.
d) None of these are correct.
True or False? Subgingival calculus usually appears lighter than supragingival calculus.
False