Triol TM01 Downhole Measuring System Surface Equipment

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/17

flashcard set

Earn XP

Description and Tags

Vocabulary practice flashcards covering terminology, technical specifications, diagnostic error codes, and hardware elements of the Triol TM01 Downhole Measuring System surface equipment.

18 Terms

1
New cards

TM01

Triol Downhole Measuring System designed to monitor, read, and process real-time telemetry parameters of fluid and downhole submersible equipment.

2
New cards

High-Voltage Choke (HVC)

An equipment block that provides an artificial zero "wye" point for telemetry connection when the secondary winding of a power step-up transformer is connected in delta mode.

3
New cards

0-SUT

The step-up transformer zero point wire connection used to link surface equipment with the downhole sensor through the transformer wye point or High-Voltage Choke.

4
New cards

Triol Surface Card (SC)

An IP20IP20-enclosed telemetry unit installed on a 35 mm35\,\text{mm} DIN rail inside a Variable Speed Drive (VSD), operating on 24 VDC24\,\text{VDC} (+10,−20%+10, -20\%) with an LCD screen, Wi-Fi, RS-485, and RS-232 interfaces.

5
New cards

Triol Surface Board (SB)

An IP20IP20-enclosed telemetry card designed for installation inside a VSD, operating at 110 V110\,\text{V} (±10%\pm 10\%) or 220 V220\,\text{V} (±20%\pm 20\%) and transmitting data via RS-485 and RS-232 Modbus RTU.

6
New cards

Triol Surface Panel (SP)

An IP56IP56-enclosed standalone surface unit featuring a 20×420 \times 4 character LCD display and a UMKA-04 controller, designed for real-time monitoring and processing of submersible equipment parameters.

7
New cards

UMKA-04 Controller

The built-in controller of the Surface Panel that includes navigation control buttons, an LCD screen, and three status indicator LEDs: Operation (green), Warning (yellow), and Alarm (red).

8
New cards

Extreme inclusion of a Surface Panel button

A switch (element 1717 on the Surface Panel bottom) used to manually power on the panel if the internal thermostat fails; recommended for use at ambient temperatures above −20∘C-20^\circ\text{C}.

9
New cards

Surface Board DG

A variant of the Triol Surface Board designed for downhole unit TM01-12, operating at 220 V220\,\text{V} (±20%\pm 20\%), a maximum power consumption of 100 W100\,\text{W}, and 200 V200\,\text{V} in the communication circuit.

10
New cards

DMS Connection Error 1

A telemetry error condition indicating low insulation resistance of less than 10 kΩ10\,\text{k}\Omega.

11
New cards

DMS Connection Error 2

A telemetry fault indicating an error switching on the immersion part with no power reaching the downhole sensor, commonly caused by an open circuit or a blown High-Voltage Choke fuse.

12
New cards

DMS Connection Error 3

A communication error indicating that the downhole sensor fails to transfer data to the surface equipment (SC, SB, or SP).

13
New cards

DMS Connection Error 4

A CRC error indicating corrupted data integrity between the downhole sensor and surface equipment, typically resulting from high electrical interference or waveform distortion.

14
New cards

AOUT8 Block

An optional analog output module that outputs up to 88 measured parameters using configurable voltage (0–10 V0\text{--}10\,\text{V}) or current (4–20 mA4\text{--}20\,\text{mA}, 0–20 mA0\text{--}20\,\text{mA}, 0–5 mA0\text{--}5\,\text{mA}) signals.

15
New cards

SA1 Switch

A four-position DIP switch located on the NT6 board of the Surface Board used to select the communication protocol (such as Transfer, Triol, or Borets SPT-2) and configure motor temperature modes.

16
New cards

Default Modbus Configuration (SB/SC)

The standard factory settings for Modbus RTU communication: an exchange rate of 19200 baud19200\,\text{baud}, 11 stop bit, and network address 6868 (0x440\text{x}44).

17
New cards

Shelving AT.305142.455

A mounting rack structure with 88 base anchor holes of diameter 14 mm14\,\text{mm} (0.55 in0.55\,\text{in}), designed to hold both the Surface Panel and High-Voltage Choke IP56.

18
New cards
<p>TM01 Test Unit</p>

TM01 Test Unit