1/13
Vocabulary flashcards covering the key terms, equipment, variables, and procedural concepts of AQA A-Level Biology Required Practical 4 (investigating the effect of ethanol concentration on beetroot membrane permeability).
Betelin pigment
The dark red-purple pigment located inside beetroot cells whose leakage into surrounding solution is measured to determine the permeability of the cell surface membrane.
Phospholipid bilayer
The double layer of lipids forming the beetroot cell surface membrane that dissolves when exposed to ethanol, resulting in increased membrane permeability.
Colorimeter
An instrument used to convert qualitative observations of pigment intensity into quantitative data by measuring the absorbance of light passing through a sample.
Independent variable
The variable deliberately changed in the experiment, which is the percentage concentration of ethanol (0%, 20%, 40%, 60%, 80%, and 100%).
Dependent variable
The variable measured to determine membrane permeability, specifically the absorbance of light through each liquid sample using a colorimeter.
Control variables
Factors kept constant to ensure valid results, including the temperature of the water bath (37∘C), volume of solution (5ml), incubation time, surface area and mass of beetroot discs, and the source beetroot.
Bung and cling film
Coverings placed on top of test tubes to prevent water evaporation, which would otherwise make the remaining ethanol solutions more concentrated than intended.
Rinsing and patting dry
The procedure of washing and drying beetroot discs prior to the experiment to remove excess pigment released from cell membranes damaged during cutting.
Green filter
The specific colorimeter filter selected when testing red beetroot pigment solutions, chosen because green is the opposite colour on the colour wheel.
Cuvette handling
Filling the vessel approximately three-quarters full and holding it strictly by the ribbed edges or frosted triangle to prevent skin grease from interfering with light absorbance.
Colorimeter standardisation (Zeroing)
Inserting a cuvette containing pure distilled water into the colorimeter and pressing the reset (R) button to establish a baseline absorbance value of zero.
Maximum absorbance limit
A value of 2 on the colorimeter where the solution contains so much pigment that the instrument can no longer differentiate between higher concentrations.
Calibration curve
A plotted graph of mean absorbance against ethanol percentage concentration that allows the concentration of unknown ethanol samples to be determined.
Organic waste bottle
A dedicated laboratory container used to discard ethanol solutions at the end of the experiment because ethanol is harmful to the environment and cannot be poured down the sink.