computed radiography (CR)

imaging system comprised of photostimulable storage phosphor (PSP) screen, CR reader, and digital electronics

2
New cards

photostimulable storage phosphor (PSP) screen

acquire the x-ray projection image

3
New cards

CR reader

extracts the electronic latent image

4
New cards

digital electronics

converts the analog signals to digital form

5
New cards

screen-film imaging and computed radiography similarities

  • use an x-ray sensitive image receptor

  • incased un a protective cassette

  • can be used interchangeably with any x-ray imaging system

  • carry a latent image that must be made visible by processing

6
New cards

screen-film imaging and computed radiography difference

  • processing

    • screen-film: image manifested through chemical processing

    • CR: analog image converted into digital signal

7
New cards

photostimulable luminance (PSL)

halide-based phosphors that have energy storage and excitation characteristics

8
New cards

what does photostimulable luminance (PSL) enable phosphors to do?

store x-ray energy temporarily then release the energy upon excitation by a laser beam

9
New cards

what is the photostimulable phosphor (PSP) screen positioned within?

cassette or imaging plate (IP)

10
New cards

what is the commonly used phosphor material in a photostimulable phosphor (PSP) screen?

barium fluorohalide

11
New cards

what are the phosphor particulates in a photostimulable phosphor (PSP) screen bonded with, what does it form, and what is it deposited on?

a cohesive material forming a turbid structure and deposited on a base for mechanical support

12
New cards

what happens to a fraction of energy when the photostimulable phosphor (PSP) screen is exposed to x-rays?

it is stored

13
New cards

where is the imaging plate (IP) inserted and how is it processed after exposure?

inserted into a CR reader and processed by a scanning system/reader

14
New cards

imaging plate (IP) scanning system process steps (5)

  1. extracts the PSP screen from the cassette

  2. moves the screen across a high intensity scanning laser beam

  3. blue-violet light is emitted via photostimulable luminescence (PSL)

  4. light energy/signal is intensified by a photomultiplier tube

  5. analog signal is changed into an electric/signal signal by an analog to digital converter

15
New cards

what is the analog signal converted to a digital format for?

manipulation, enhancement, viewing, and printing

16
New cards

what is the PSP screen erased by and where is it reloaded into?

erased by a bright light inside the reader and reloaded into the cassette

17
New cards

how long does the CR imaging processing take?

20 seconds

18
New cards

how could the imaging plate be re-used?

a high intensity white light dumps all the remaining energy trapped

19
New cards

CR additional equipment (8)

  • CR reader

  • imaging plates & cassettes

  • QC workstation

  • diagnostic workstation/viewer

  • laser printer

  • archive server

  • web server

  • film digitizer

20
New cards

what does a CR reader replace?

darkroom, processor, and chemicals

21
New cards

what does a diagnostic viewer replace?

film, storage, and view boxes