A wall designed to prevent the spread of fire, having a fire resistance rating of not less than four hours with sufficient structural stability, is a __________.
Firewall
The minimum required first floor live load for Group A Dwellings under the National Building Code is __________.
200kg/m2
Under the National Building Code, the vacant space left between the outermost face of the building (OFB) and the property lines is called a __________.
Yard
According to Article 1723 of the Civil Code, if a building collapses due to defects in the plans, the __________ shall be held liable.
architect or the engineer who drew up the plans
For forest areas, the National Building Code requires an easement of at least __________ for each side of a waterway.
40.00m
In building regulations, the acronym FLAR stands for __________.
Floor to Lot Area Ratio
Under the National Building Code, the acronym PUD stands for __________.
Planned Unit Development
A change in the use or occupancy of buildings/structures or any portion thereof which has different requirements is defined as a __________.
Conversion
Any new construction that increases the height and/or floor area of existing buildings/structures is defined as an __________.
Addition
A building permit becomes null and void if work authorized therein is not commenced within a period of __________ from the date of such permit.
12 months
The maximum travel distance to an exit door without an automatic fire extinguishing sprinkler system is __________.
45 meters
As per the National Building Code, the maximum width of a single door leaf shall be __________.
1.20m
The sum of the Impervious Surface Area (ISA) and the Unpaved Surface Area (USA) equals the __________.
TOSL
The minimum distance required between roof eaves and the rear or side property lines is __________.
750mm
Under the National Building Code, the minimum ceiling height at the ground floor for a habitable room with natural ventilation is __________.
2.70m
Under PD 1096, the least dimension of a kitchen is __________.
1.5m

In the provided subdivision layout, the lot indicated as B fronting both the street and the cul-de-sac turnaround is classified as a __________.
Corner-Through Lot
Under PD 1096, the least dimension of a toilet and bath is __________.
0.90m
The rule in the National Building Code that covers the Classification and General Requirement of All Buildings by Use or Occupancy is __________.
Rule VII
Under RA 9514 (Fire Code of the Philippines), the document FSCCR stands for __________.
Fire Safety Compliance and Commissioning Report
Under RA 9514, a building that is unsafe in case of fire because it will burn easily or because it lacks adequate exits is called a __________.
Fire Trap
A continuous and unobstructed route of exit travel from any point in a building to a public way is known as the __________.
Means of Egress
Under BP 344, the maximum allowable slope for ramps intended for persons with disabilities (PWD) is __________.
1:12
Under BP 344, handrails for ramps, stairs, and dropped curbs at crossings should be installed at heights of __________ above the floor.
700mm and 900mm
The minimum width of an accessible parking slot for persons with disabilities under BP 344 is __________.
3.70m
Under BP 220, the minimum lot frontage for Socialized Row Houses is __________.
3.5m
Under PD 957, the minimum lot frontage for Row Houses is __________.
4m
Under both PD 957 and BP 220, the maximum number of row house units permitted per block or cluster is __________.
20
For BP 220 housing projects, the minimum extension of a firewall above the roof line is __________.
300mm
Under BP 220, block lengths exceeding 250m must be provided with an alley approximately at midlength having a minimum width of __________.
2.00m
The law known as the Urban Development and Housing Act (UDHA) of 1992 is __________.
RA 7279
The Philippine law known as the Philippine Environmental Policy is __________.
PD 1151
The Philippine law known as the Philippine Environmental Code is __________.
PD 1152
According to the National Building Code, the maximum vertical height between stairway landings is __________.
3.60m
According to the National Building Code, the minimum required live load for the second floor of a residential building (Group A Dwelling) is __________.
150kg/m2