1/45
Looks like no tags are added yet.
Goals of Induction (5)
Smooth transition from awake to anesthetized (stage 1 to 3)
Decrease amount of inhalant used
Enable us to secure airway (in most cases)
Need muscle relaxation
These goals are often met with the use of injectable anesthetics
how many stages of anesthesia are there?
4
what phase is stage 1 known as
induction / disorientation
what phase is stage 2 known as
Excitement phase
stage 2 is known for (8)
Incoordination
Struggling
progressive relaxation
unconsciousness
May hamper restraint
predispose to injury
vomiting
cardiac arrhythmias
stage 3 is known as what phase
unconscious
what are the 3 stages in stage 3
Light
Surgical
Deep
what phase is stage 4 known as
overdose phase
Gas induction Concerns (9)
Restraint without restriction of breathing
Fear with stage 1/stage 2 can cause catecholamine release which predisposes to arrhythmias
Indicators of anesthetic depth difficult to assess
Exposure to waste gases
Longer induction time
Not able to protect the airway
Not able to prevent aspiration
Not able to provide ventilatory support
Harder to observe respiration
what are the different induction techniques (7)
IM induction (Single dose)
IV induction (Single dose)
IV induction and maintenance with multiple IV boluses (TIVA)
IV induction and maintenance with constant rate IV infusion (CRI)
Inhalation Induction and Maintenance with inhalation agent
IM induction and Maintenance with an inhalation agent
IV induction and Maintenance with an inhalation agent
IM induction (Single dose) is usually done if (2)
animal can’t be handled
not enough anesthetic machines
IM induction (Single dose) — be titrated
a. can be
b. can’t be
b. can’t be
IV induction (Single dose) Technique for — procedures that require less than — mins of anesthesia
short , 10 mins
procedure for Chamber Induction for a Dog or Cat (5)
Place the conscious animal inside an anesthetic chamber. The chamber should be large enough for the patient to lie down with its neck extended. If the patient can be handled, an ophthalmic lubricant should be applied before the patient is placed in the induction chamber.
Remove the Y-piece of a rebreathing circuit and attach one corrugated hose to each port of the chamber.
Deliver a mixture of oxygen at 5 L/min and isoflurane at 3%–5% or sevoflurane at 4%–5%.
During passage through stages I and II, patients typically exhibit fear and agitation. The patient may attempt to escape or vocalize. Gradually, with the onset of anesthesia, the patient will become increasingly depressed and immobile.
As soon as the patient can no longer stand, rock the chamber gently to assess the patient’s status. Initially, the patient will respond by righting itself until anesthesia is ofsufcient depth to prevent purposeful movement. When the patient is immobile enough to allow it to be safely handled, remove it from the chamber, place a mask, and proceed as with mask induction.
how To minimize exposure to waste anesthetic gas (7)
Ideally, enlist the help of two people (one to open, close, and manage the chamber and one to hold the patient) so that the waste gas can be managed without compromising patient safety.
Check that the lid is properly sealed before commencing chamber induction.
Perform chamber induction in an area that is well ventilated (with at least 15 air changes per hour).
Avoid opening the chamber any more often than necessary.
Turn the vaporizer off before removing the lid.
Ideally, before removing the lid, run pure oxygen to scavenge as much waste gas as possible. This is often not possible, however, because of the need to check vital signs rapidly, ensure a patent airway, and perform endotracheal intubation.
Remove the patient quickly, immediately replace the lid, and continue to run pure oxygen at a rate of 5 L/min for at least 2–3 min to purge waste gas from the system.
Sequence of events for induction of general anesthesia with an intravenous agent and maintenance with an inhalant agent in a small animal patient
Administer premedications IM approximately 15–20 min or IV approximately 5–10 min before anesthetic induction.
Place an intravenous catheter, attach a fluid administration set, and begin fluid administration.
Administer the induction agent.
Check the patient's readiness for intubation.
Place and secure the endotracheal tube.
Check the patient's vital signs.
Turn on the oxygen and connect the endotracheal tube to the breathing circuit.
Inflate the endotracheal tube cuff.
Turn the vaporizer on to the appropriate setting.
Determine the patient's anesthetic depth and commence regular monitoring.
Position and secure the patient for the procedure, giving attention to padding, maintenance of an open airway, unrestricted blood flow, and unrestricted chest excursions.
Attach monitoring devices.
Continue to monitor and adjust the anesthetic and oxygen levels as needed until completion of the procedure.

what is it
dorsal pharyngeal wall

what is it
esophageal aditus

what is it
circoid arch

what is it
corniculate process

what is it
piriform recess

what is it
cuneiform process

what is it
vocal folds

what is it
ventricle aperture

what is it
epiglottis

what is it
tongue
equipment required for intubation (7)
A length of IV tubing or rolled gauze to secure tube to patient
Syringes to inflate cuff (Proper size: Not too big!)
Light to visualise glottis
Stylette for smaller tubes to help with placement
Lidocaine injectable or gel (feline patients)
Laryngoscope
ET Tube
how many et tubes should be chosen
3
how to measure length for ET tube
Tip of nose to thoracic inlet
advantages of ET tube (6)
Maintain an open airway
More efficient delivery of anesthetic gas than a mask
Reduces risk of aspiration
Improve efficiency of gas exchange by reducing anatomic dead space
Anesthetist can support ventilation by manual or mechanical means
Reduces waste gas exposure to staff
complications of ET tubes (13)
Vagal Reflex
Damage to larynx, pharynx and glottis (may cause laryngospasm)
Pressure necrosis of trachea
Obstruction
Chewing tube in half
Infection
Cuff Not Inflated
cuff Underinflated
Overzealous Intubation
Tube Kinked
Obstructed
Tube Not Removed Before Return to Consciousness
improper size
what needs to be done when flipping a patient
disconnect breathing tube from the circuit
what can happen if Tube Not Removed Before Return to Consciousness (3)
Damage to the tube from chewing
Blockage of the airway
a severed portion of the tube can be aspirated or swallowed
what happens if the tube isn’t wide enough (3)
Poor seal
Restricts air flow
Small tubes more likely to block with mucus
what happens if a tube is Too wide / cuff overinflated (3)
Pressure on trachea, which could result in damage
Necrosis of the tracheal mucosa
Possibility of tracheal rupture in extreme situations
what happens if the tube is too long (3)
Ventilation of only one lung
Increased mechanical dead space
Leading to hypoventilation and hypoxia
what happens if the tube is too short (2)
Inability to intubate the patient successfully
Displacement of the tube from the glottis if the patient’s body position is changed
what happens if the Tube Not Cleaned and Disinfected (5)
Transmission of infectious agents
leading to tracheitis
bronchitis
pneumonia
Blockage of the tube with dried mucus or other foreign material
define Laryngospasm
Reflex closure of the glottis in response to contact with any object or substance
how to prevent laryngospasm (5)
Apply lidocaine to the arytenoids first
Wait 30-60 secs to take effect before attempting intubation
Be sure patient is adequately anesthetized before attempting to intubate
Wait for glottis to open before attempting and get tube in first time !
Never force the tube !!
When is our patient ready to intubate? (5)
Unconscious
Lack of voluntary movement
Absent pedal reflex (Pinch toe)
Sufficient muscle relaxation to allow the mouth to be held open
No swallowing when the tongue is grasped
Procedure of intubating (16)
Place the patient in sternal recumbency
Have an assistant grasp the patient’s maxilla behind the canine teeth, extend the neck, and raise the head so that the head and neck are in a straight line. Be sure the lips and whiskers are pulled dorsally and out of the line of sight. The neck should be propped upright and not allowed to sag. The as-sistant should not push on the ventral aspect of the neck, head, or throat because this may obscure the view, making intubation difficult.
Grasp the tongue with a gauze sponge and open the mouth fully by firmly pulling the tongue out and down. A mouth gag can be used to hold the mouth open.
Adjust the light so that the larynx is well illuminated
If necessary, use the tube or laryngoscope gently to displace the epiglottis ven-trally or the soft palate dorsally until the glottis can be visualizedb. When using a laryngoscope, press down on the base of the tongue below the epiglottis to aid in visualizing the glottis
Gently insert the tube past the vocal folds using a rotating motion, but never force the tube!. If the tube is too large to pass easily, exchange the tube for one of smaller diameter
After the tube has been placed, gently transfer the patient into lateral recumbency.
Check the tube to ensure that it is in the trachea. Then check that it is inserted to an appropriate distance and is oriented to match the natural curve of the trachea.
Secure the tube in place with a tie (e.g., length of used IV administration set tubing, hard roll gauze, shoelace, or commercial tie designed for this purpose).
Position the tongue so that it hangs loosely from the mouth and is not compressed by the tie.
Turn on the oxygen owmeter(s).
Connect the endotracheal (ET) tube connector to the breathing circuit.
Inate the cuff and check for leaks.
Turn on the anesthetic vaporizer and select the appropriate setting (if main-taining with an inhalant agent).
Commence regular monitoring.
ensure a patent airway by checking the position of the patient and tube. The neck and tube should assume a gentle natural curve.
how to confirm et tube placement (9)
Visualized
Bag movement
Feel for air movement
Fogging
Valves opening properly
Palpate
Patient ability to vocalize
Coughing
Capnograph (if no reading = not in the right place)
whats an SGAD
an alternative to an endotracheal tube for maintain-ing an open airway and transferring anesthetic gases directly from the breathing circuit to the lower respiratory tract
the v-gel advanced SGAD can be used in what animals (3)
cats
rabbits
dogs
what does SGAD stand for
Supraglottic Airway Devices