Which respiration phase elevates the diaphragm and abdominal viscera shortens the lung fields depresses the sternum and lowers the ribs and increases their angle near the spine?
expiration
Which respiration phase depresses the diaphragm and abdominal viscera lengthens and expands the lung fields elevates the sternum and pushes it anteriorly and elevates the ribs?
inspiration
Which factors will minimize distortion?
CR-part alignment
When imaging an obese patient, which landmarks are difficult to palpate?
Jug notch
ASIS
Iliac crest
greater trochanter
ASIS
Iliac crest
greater trochanter
To work effectively with obese patients, all of the following have been adapted except for
image receptor sizes
A PA projection of the hand should be displayed:
from the perspective of the x-ray tube and with the fingers pointing upward
Who is responsible for obtaining a necessary clinical history when the radiologist is unable to see the patient?
radiographer
To dispose of a hypodermic needle properly, it should be:
placed in a puncture proof container
which of the following technical factors is most important to adjust and increase when imaging an obese patient?
kVp
Within the OR, who should remove sterile items that are in the way of the radiographer?
circulating nurse
To prepare the patient for a radiographic examination of the abdomen, what are the three methods used for cleansing the patient's bowel?
limited diet laxatives and enemas
Which type of muscle tissue comprises peristalsis?
smooth
Which type of muscle tissue comprises skeletal muscle?
striated
Which pathologic condition requires a decrease in exposure factors from the routine procedure?
edema
pneumonia
emphysema
pleural effusion
emphysema
Which change in exposure factors should be used to control voluntary motion that is a result of the patient's age or mental illness?
decrease the exposure time
Which procedure best reduces the possibility of patient-controlled motion?
give understandable instructions to the patient
which side marker placement is recommended when performing an AP axial oblique radiograph of the cervical spine?
mark the side closest to the IR
which piece of info is not required as part of the ID of radiographs
name of pt
date of exam
name of radiographer
name of medical facility
name of radiographer
What is the primary purpose of collimating to the area of interest?
reduce pt exposure
How is radiographic image quality affected when the radiation beam is restricted to the area under examination only?
increased radiographic contrast resolution
Which would cause an artifact on a chest radiographic exam?
bra
glasses
hearing aid
denim jeans
bra
Which change most improves spatial resolution when the sternum is imaged?
decreasing the SID
the most common IR position is
lengthwise
regardless of the type if imaging equipment what is the recommended first procedural step for a radiographic examination
prep room and gather equipment
What is the IR in direct digital radiography?
Solid-State Detector
When using a fixed, large IR, how is collimation (field size) controlled?
manually by the radiographer
Reasons to avoid using electronic side marker place ment ( annotation ) in digital imaging include :
increased potential for errors
increased legal implications
The knowledge, skills, ability, and behaviors that are essential for providing optimal care to defined groups of patients is termed:
age specific competence
When imaging obese patients, all of the following should be taken into consideration except for:
selecting larger IR sizes and larger collimation settings for DR
The approximate distance from the jugular notch to the pubic symphysis on a patient who is more than 6 feet (183 cm) tall is:
61 cm 24 inches
which organization maintains the code of ethics for the profession?
arrt
which organization maintains the practice standards for medical imaging and radiation therapy?
ASRT
which organization provides directives for infection control?
CDC
all are reasons to angle the central ray except
To reduce magnification of the imaged anatomy
SID affects all of the following, except:
a. Magnification
b. Spatial resolution
c. Placement of the side marker
d. Patient dose
placement of the side marker