To preserve the integrity of reagent strips, it is necessary that they are
stored in a tightly capped container
Which of the following is not a source of erroneous results when reagent strips are used?
Dipping the reagent strip briefly into the urine specimen
Which of the following is not checked by quality control materials?
The integrity of the specimen, that is, that the specimen was collected and stored properly
Which of the following is checked by quality control
materials?
The technical skills of the personnel performing the test
The test protocol, that is, that the procedure was performed according to written guidelines
The functioning of the equipment used—for example, the refractometer and the reagent strip readers
Quality control materials used to assess the performance of reagent strips and tablet tests must
contain chemical constituents at realistic and critical detection levels.
Using quality control materials, one should check reagent strip performance
at least once daily.
when a new bottle of strips or tablets is opened.
when a new lot number of strips or tablets is placed into use.
Select the primary reason why tablet (e.g., Ictotest) and chemical tests (e.g., sulfosalicylic acid precipitation test) generally are performed.
Their specificity differs from that of the reagent strip test.
Urine pH normally ranges from
4.5 to 8.0.
Urine pH can be modified by all of the following except
increased ingestion of water.
Urine pH can be modified by all of the following
Diet
medications
UTI
Commercial reagent strips use which of the following reactions to determine urine pH?
Double indicator combinations
All of the following can result in inaccurate urine pH measurements except
large amounts of protein present in the urine.
All of the following can result in inaccurate urine pH measurements
double-dipping of the reagent strip into the specimen.
maintaining the specimen at room temperature for 4 hours.
allowing excess urine to remain on the reagent strip during the timing interval.
Normally, daily urine protein excretion does not exceed
150 mg/day
Which of the following proteins originates in the urinary tract?
Uromodulin
Tubular Proteinuria is described as
Defective protein reabsorption in the nephrons
Increase in LMW proteins in urine
Overflow of proteinuria is described as
Immunoglobulin light chains in the urine
HGB and Myoglobin
Glomerular proteinuria is described as
Increased urine albumin and mid- to high-molecular- weight proteins
Protein excreted only in an orthostatic position
Nephrotic syndrome
Postrenal proteinuria is best described as
Proteins originating from a bladder tumor
Which of the following statements about Bence Jones protein is correct?
The protein consists of κ and λ light chains.
Which of the following statements best describes the chemical principle of the protein reagent strip test?
The protein accepts hydrogen ions from the indicator dye, which results in a color change
What aids in the differentiation of hemoglobinuria and hematuria?
Microscopic examination
_______ are reabsorbed readily by renal tubular cells
Myoglobin and hemoglobin
When haptoglobin is saturated, free hemoglobin passes through the _____________.
glomerular filtration barrier
What best describes Hemoglobin and myoglobin
They are heme-containing proteins involved in oxygen transport.
On the reagent strip test for blood, any heme moiety (e.g., hemoglobin, myoglobin) present in urine catalyzes
oxidation of the chromogen while hydrogen peroxide is reduced.
Which of the following blood cells will not be detected by the leukocyte esterase pad because it lacks esterases?
Lymphocytes
Which of the following blood cells will be detected by the leukocyte esterase pad because it lacks esterases?
EOS
MONO
NEU
Microscopic examination of a urine sediment revealed an average of 2 to 5 white blood cells per high-power field, whereas the leukocyte esterase test by reagent strip was negative. Which of the following statements best accounts for this discrepancy?
The amount of esterase present is below the sensitivity of the reagent strip test
Which of the following statements describes the chemical principle involved in the leukocyte esterase pad of commercial reagent strips?
Leukocyte esterase hydrolyzes an ester on the reagent pad; then an azo coupling reaction results in the formation of an azo dye.
List all conditions that most likely accounts for a negative nitrite result on the reagent strip despite the presence of large quantities of bacteria
The bacteria present did not have enough time to convert nitrate to nitrite.
The bacteria present are not capable of converting nitrate to nitrite.
The patient is not ingesting adequate amounts of nitrate in the diet.
The urine is dilute and the level of nitrite present is below the sensitivity of the test.
The chemical principle of the nitrite reagent pad is based on the
diazotization of nitrite followed by an azo coupling reaction
What substances or actions can produce false-positive nitrite results?
Improper specimen storage
A urine specimen is tested for glucose by a reagent strip and by the Clinitest method. The reagent strip result is 100 mg/dL, and the Clinitest result is 500 mg/dL. Which of the following statements would best account for this discrepancy?
A large amount of ascorbic acid is present in the specimen.
Which of the following substances if present in the urine results in a negative Clinitest?
Sucrose
The glucose reagent strip test is more sensitive and specific for glucose than the Clinitest method because it detects
no other substances and lower concentrations of glucose
What are true statements about glucose
Glucose readily passes the glomerular filtration barrier.
Glucosuria occurs when plasma glucose levels exceed 160 to 180 mg/dL.
High plasma glucose concentrations are associated with damage to the glomerular filtration barrier.
The pass-through phenomenon observed with the Clinitest method when large amounts of glucose are present in the urine is due to
reoxidation of the cuprous oxide formed to cupric oxide and other cupric complexes.
The glucose specificity of the double sequential enzyme reaction used on reagent strip tests is due to the use of
glucose oxidase.
Which ketone is not detected by the reagent strip or tablet test?
β-Hydroxybutyrate
What ketone is are detected by the reagent strip or tablet test?
Acetone
Acetoacetate
Which of the following can cause false-positive ketone results?
Drugs containing free sulfhydryl groups
Which of the following will not cause ketonemia and ketonuria?
Increased metabolism of carbohydrates
What can cause Ketonemia and Ketonuria
An inability to use carbohydrates
Inadequate intake of carbohydrates
Excessive loss of carbohydrates
The ketone reagent strip and tablet tests are based on the reactivity of ketones with
nitroprusside
Bilirubin is a _____ Product of heme catabolism.
degradation
The bilirubin reagent strip and tablet tests are based on
the coupling of bilirubin with a diazonium salt.
What are characteristic urine findings from a patient with hemolytic jaundice?
A negative test for bilirubin and an increased amount of urobilinogen
Which results shows characteristic urine findings from a patient with an obstruction of the bile duct?
A positive test for bilirubin and a decreased amount of urobilinogen
Which of the following conditions can result in false-positive bilirubin results?
Ingestion of certain medications
Urobilinogen is formed from the
reduction of bilirubin by intestinal bacteria.
Urobilinogen is labile and readily ______ to urobilin
photo-oxidizes
The classic Ehrlich’s reaction is based on the reaction of urobilinogen with
p-dimethylaminobenzaldehyde
What chemical principles is most specific for the detection of urobilinogen?
Azo coupling reaction
What reagent strip tests can be affected by ascorbic acid, resulting in falsely low or false-negative results
Blood
Bilirubin
Glucose
Nitrite
What best describes the mechanism of ascorbic acid interference?
Ascorbic acid removes a reactant from the intended reaction sequence