1/65
Looks like no tags are added yet.
Anticoagulant
A chemical additive that prevents blood from clotting either by binding calcium (EDTA, potassium oxalate, SPS) or by inhibiting thrombin (heparin).
Antiglycolytic agent
A tube additive (such as sodium fluoride) that prevents blood cells from breaking down glucose.
Antiseptic
A substance used to clean the skin before blood collection, such as 70% isopropyl alcohol for routine venipuncture or iodine/chlorhexidine gluconate for blood cultures.
Bevel
The angled, slanted tip of a needle that allows it to pierce the skin and vein wall.
Hemolyzed
A pink-red specimen appearance that indicates erythrocyte (red blood cell) destruction.
Hemostasis
The body's process of forming a blood clot when injury occurs and lysing (breaking down) the clot once the injury is repaired.
Holder
A plastic tube-guiding cylinder used in an evacuated tube system; examples include Venipuncture Needle-Pro, VanishPoint, and BD One-Use.
Hub
The threaded plastic section of a needle that attaches to the holder or syringe.
Hypodermic needle
A single-pointed, hollow needle used with a syringe for blood collection.
Icteric
A dark yellow specimen appearance caused by increased bilirubin.
Lipemic
A milky specimen appearance caused by increased lipids.
Lumen
The hollow inner channel inside a needle through which blood flows.
Multi-sample needle
A double-pointed needle used with an evacuated tube system that allows multiple tubes to be filled during one venipuncture.
Plasma
The liquid portion of unclotted blood (collected in an anticoagulated sample) that contains fibrinogen.
Plasma separator tube (PST)
A collection tube (such as BD light green) containing lithium heparin and separation gel that separates plasma from cells.
Serum
The liquid portion of clotted blood (collected in a clot tube) that does not contain fibrinogen.
Serum separator tube (SST)
A gold or red-gray collection tube containing a silica clot activator and gel that separates serum from clotted cells after 30 minutes of clotting.
Winged blood collection set
A collection system (butterfly) used for IV fluid infusion, very small adult veins, and pediatric samples; requires a clear discard tube to prime the line for coagulation tests.
Coagulation
The clotting process involving blood vessels, platelets, and coagulation factors.
Coagulation Stages
Stage 1: Primary hemostasis; Stage 2: Secondary hemostasis; Stage 3: Clot stabilization; Stage 4: Fibrinolysis.
Arterial Blood
Blood collected from an artery for blood gas testing; requires special collection training.
Venous Blood
The sample of choice for laboratory testing because standard reference ranges are established from venous blood.
Capillary Blood
A mixture of arterial and venous blood collected by dermal puncture; must be noted on the requisition.
Whole Blood
An anticoagulated blood specimen consisting of erythrocytes, leukocytes, platelets, and plasma.
Normal Plasma and Serum
Appears clear and pale yellow.
Blood Collection Tray
A portable carrier used for equipment transport; requires proper placement and regular disinfection.
Evacuated Tube System (ETS)
A three-part closed system (needle, safety shield/holder, and evacuated tube) that eliminates blood transfer and minimizes exposure to blood.
Needles (Length & Gauge)
Sterile, disposable, one-time-use devices; lengths are 3/4, 1, and 1.5 inches; gauges have color-coded caps.
Standard Needle Gauge
21–22 gauge (20-gauge is not recommended for routine collection due to issues with blood thinners; 25-gauge causes slow filling, microclots, and frequent hemolysis).
Safety Needles
Needles equipped with shields, blunting devices, or retracting mechanisms; NEVER manually recap a needle after removing the shield.
Needle Disposal Systems
Rigid, puncture-resistant, leak-proof sharps containers with biohazard labeling used for the immediate direct disposal of needles and attached assemblies.
Hemogard Closure
A protective plastic shield covering the rubber stopper on evacuated collection tubes.
Evacuated Tube Labels
List the additive, draw volume, lot number, and expiration date (which ensures stability of vacuum, anticoagulants, and additives).
Syringe System
A collection method used for small, fragile veins because suction pressure on the vein can be manually controlled.
Blood Transfer Device
A safety holder used to quickly transfer blood from a syringe into evacuated tubes without clot formation; the entire assembly is discarded in a sharps container.
Tourniquets
Disposable nonlatex strips or blood pressure cuffs (maintained at 40 mm Hg) used to make veins easier to locate.
Venoscope
A transillumination light device placed on the skin to help locate difficult veins.
Gloves
OSHA-mandated, nonlatex, powder-free personal protective equipment worn during all blood collections.
Gauze and Bandages
2 x 2 gauze pads used to apply pressure to the puncture site; latex-free bandages/tape or self-adhesive gauze applied after bleeding stops and removed after 15 minutes.
Lavender Tube
Anticoagulant: K2 or K3 EDTA (CLSI recommends spray-dried K2 EDTA). Sample: Whole blood. Invert: 8 times. Use: Complete blood count (CBC); inhibits platelet clumping, maintains cellular integrity, and never used for coagulation tests.
Pink Tube
Anticoagulant: K2 EDTA. Sample: Whole blood. Invert: 8 times. Use: Blood bank tests; requires a special AABB label.
White Tube (PPT)
Anticoagulant: K2 EDTA with gel. Sample: Plasma. Invert: 8 times. Use: Molecular diagnostic tests.
Light Blue Tube
Anticoagulant: Sodium citrate (9:1 blood-to-anticoagulant ratio). Sample: Plasma. Invert: 3–4 times (overmixing activates platelets). Use: Coagulation tests; incomplete fill is rejected by the lab.
Dark Blue Tube
Additives: Thrombin and soybean trypsin inhibitor. Sample: Plasma. Use: Fibrin degradation products.
Black Tube
Anticoagulant: Sodium citrate (4:1 blood-to-anticoagulant ratio). Sample: Whole blood. Invert: 8 times. Use: Westergren sedimentation rates (uses a specially designed tube and holder).
Green Tube
Anticoagulant: Heparin (sodium, lithium, or ammonium). Sample: Plasma/whole blood. Invert: 8 times. Use: Chemistry tests (avoid interference with Na, NH4, Li tests; interferes with differential staining).
Light Green Tube (BD PST)
Anticoagulant: Lithium heparin with separation gel (Vacuette = green with yellow circle). Sample: Plasma. Invert: 8 times. Use: Separates plasma from cells; ideal for potassium and other chemistry tests.
Gray Tube
Additives: Potassium oxalate or Na2EDTA (or no anticoagulant) + sodium fluoride (antiglycolytic agent). Sample: Plasma or serum. Invert: 8 times. Use: Glucose and blood alcohol levels (NaF interferes with some enzymes; K oxalate distorts RBC morphology).
Royal Blue Tube
Additives: Plain with clot activator, sodium heparin, or K2EDTA (chemically clean with special rubber stoppers). Sample: Serum or plasma. Invert: 8 times (plasma) or 5 times (serum). Use: Trace elements, toxicology, and nutrients.
Tan Tube
Anticoagulant: K2EDTA (contains less than 0.01 µg/mL lead). Sample: Plasma. Invert: 8 times. Use: Lead testing.
Yellow Tube (ACD)
Additive: Acid citrate dextrose (ACD) to preserve RBCs. Sample: Whole blood. Invert: 8 times. Use: Blood bank tests.
Yellow Tube (SPS)
Additive: Sodium polyanethol sulfonate (SPS) to aid microorganism recovery. Sample: Whole blood. Invert: 8 times. Use: Microbiology blood cultures.
Orange Tube (RST)
Additive: Thrombin with gel (Rapid Serum Tube). Sample: Serum. Invert: 8 times. Use: STAT serum chemistry tests (clots in 5 minutes).
Gold / Red-Gray Tube (SST)
Additives: Silica clot activator and gel (Vacuette = red with yellow circle). Sample: Serum. Invert: 5 times. Use: Chemistry tests (clots in 30 minutes; do not use for blood bank or some immunology/serology tests).
Red Plastic Tube
Additive: Silica clot activator. Sample: Serum. Invert: 5 times. Use: Immunology, chemistry, and blood bank testing.
Red Glass Tube
Additive: None (no anticoagulants or additives). Sample: Serum. Invert: 0 times. Use: Chemistry, serology, and blood bank testing (clots in 60 minutes).
Clear / Red-Light Gray Tube
Additive: None. Use: Discard tube (such as priming a winged collection set before coagulation tests).
Purpose of Order of Draw
Prevents specimen contamination by tissue thromboplastin, anticoagulants, additives, and microorganisms (applied identically to both ETS and syringe draws).
CLSI Order of Draw (Step 1)
Sterile samples: Blood culture bottles and Yellow (SPS).
CLSI Order of Draw (Step 2)
Light blue (sodium citrate).
CLSI Order of Draw (Step 3)
Serum tubes: Red plastic (clot activator), Red glass (no additive), Red-gray/Gold SST, Orange RST, and Royal blue with clot activator.
CLSI Order of Draw (Step 4)
Heparin tubes: Light green PST, Green, and Royal blue with heparin.
CLSI Order of Draw (Step 5)
EDTA tubes: Lavender, Pink, Tan, Royal blue with EDTA, and White PPT.
CLSI Order of Draw (Step 6)
Gray (potassium oxalate / sodium fluoride).
CLSI Order of Draw (Step 7)
Yellow (ACD).