1
New cards

settings cog

defines if pacing parameters are programmed through the mapping system or external EP stimulator

2
New cards

vein mode

acquiring and delineating geomtry within a distinct anatomical region

3
New cards

euclidean distance

shortest possible distance bw two points

4
New cards

pace all

routes stimuli to both sphere 9 catheter lattice and mini surface electrodes in a rapid burst once every pacing period

5
New cards

geodesic distance

measures distance following curvature of map

6
New cards

what is pace all useful for

testing phrenic nerve capture

7
New cards

pace minis

routes pacing stimuli to all sphere 9 catheter mini surface electrodes in a rapid sequential burst once every pacing period

8
New cards

what are pace minis useful for

testing for exit block from a PV

9
New cards

STIM

delivers pacing as programmed

10
New cards
<p>what are these</p>

what are these

atrial trigger

ventricular trigger

stim trigger

11
New cards

what does new map do

creates capability for a new geometry and EA information

12
New cards

what does remap do

initializes the map using the chamber and geometry from an existing source map

13
New cards

what does clone do

creates a full copy of an existing source map including chamber, rhtyhm, WOI, geo, and electrogram data

14
New cards

what does import do

creates a geo shell from a surface file saved on an external usb drive

15
New cards

respiration gating

the % of stable respiratory cycle that geometry and electrogram data is collected

16
New cards

voltage threshold

min voltage required for activation timing to be assigned to the point

17
New cards

activation threshold

how sharp a signal must be to be annotated, measured in V/s with the purpose to discriminate between near-field and far-field activity

18
New cards
<p>which part is when info is collected and which part is when info is not collected</p>

which part is when info is collected and which part is when info is not collected

collected: white portion

not collected: orange portion

19
New cards

fast remap

initializes a map using the active map’s geometry, chamber, rhythm, and WOI

20
New cards

what does it mean when the outer ring is smaller? when larger?

the displayed cath location is near the surface of the map

displayed cath location is further from the surface of the map

21
New cards

dashed line vs solid line around the catheter

dashed: reduced local impedance

solid: increased local impedance

22
New cards

what do the orange and blue outlines mean on the sphere globe

orange: F curve deflection

blue: D curve deflection

23
New cards

if the ablation button is gray or black, what could that be due to?

poor location quality

rapid cath movement

respiration gating

triggers not detected

V trigger signals are inconsistent with stim trigger

errors on patches/displacement

24
New cards

Tag Connect Thresholds for PFA and RF

RF: 7-8mm

PFA: 5 mm

25
New cards
<p>describe these</p>

describe these

1.utilizes integral sensor temp rise above baseline value to determine ablation tags

2.when checked, ablation tags are shaped, positioned, and oriented based on sensors meeting temp criteria

3.when checked, ablation tags are displayed as transparent shapes with a white border

4.when checked, ablation tags within geo shell are obstructed


26
New cards

RF temp threshold

50 degrees C

27
New cards

PF temp threshold

one or two degrees above pt’s temp

28
New cards

impedance measurement

measured between the ablation electrode and the return electrodes

29
New cards

flow

real time flow rate ml/min being delivered by the HexaFlow irrigation pump, with target flow shown in bottom left

30
New cards

temperature measurement in treat mode

real time temp in C measured with the ablation catheter; max temp across all temp sensors

31
New cards

level measurement in treat mode

real time current level % being delivered by the HexaGen RF generator or the PFA generator

32
New cards

during RF, level is reported as?? what about PFA??

RF: % of the max current squared

PFA: % of the max current

33
New cards

blue tag connect line

inter - ablation distance is greater than the user defined criteria

34
New cards

blue ablation tag

temp criteria for an ablation was not met

35
New cards

grey tag connect line

interablation distance is lower than the manually set criteris

36
New cards
<p>what do the two orange lines mean?</p>

what do the two orange lines mean?

bright orange: max temp for al 9 sensors

dark orange: other temp sensors

37
New cards

what is the hierarchy of triggers when multiple are selected?

stim

atrial

Ventricle

38
New cards

is it an appropriate WOI if it spans 250ms but the TCL is 256ms?

yes because the WOI covers approximately 100% of the TCL

39
New cards

rec triggers selected for sinus

A and V

40
New cards

rec triggers selected for internally paced

S and V

41
New cards

rec triggers selected for Afib

V

42
New cards

rec triggers selected for aflutter or tach

A

43
New cards

WOI boundaries for sinus

left boundary: pre p wave

right boudnary: pre QRS

44
New cards

WOI boundaries for internally paced

left boundary: post pacing spike +10ms

right: pre QRS

45
New cards

WOI boundaries for afib

left: ~300ms pre QRS

right:pre QRS

46
New cards

WOI boundaries for aflutter or tach

physician preference or 100% TCL or 50/50 around trigger

47
New cards
<p>where is the ablation </p>

where is the ablation

knowt flashcard image
48
New cards
term image

when 1 sensor exceeds the user defined threshold, the ablation tag is flattened into a disc centered on the sensor that met criteria

49
New cards
term image
knowt flashcard image
50
New cards
term image
knowt flashcard image
51
New cards
term image


52
New cards

inter ablation distance

distance between the closest temp sensore that have met the user defined temp threshold