Code of Practice for Fire Safety in Buildings - Vocabulary & Key Concepts

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/40

flashcard set

Earn XP

Description and Tags

Comprehensive vocabulary flashcards covering regulatory definitions, means of escape, fire resisting construction, fire engineering principles, and evacuation timelines from the Code of Practice for Fire Safety in Buildings.

41 Terms

1
New cards

Access staircase

A staircase designed and constructed to allow firemen safe and unobstructed access to all storeys of a building in the event of fire.

2
New cards

Balcony approach

A balcony that serves as an external approach to a common staircase and serves two or more occupancies.

3
New cards

Basement

Any storey located below the lower or lowest ground storey from which any exit route is in an upward direction.

4
New cards

Bounding Conditions

A set of fire safety provisions that must be maintained as a result of a performance-based approach to fire safety design, which if altered will invalidate the performance-based design.

5
New cards

Compartment area

The area of the floors of a building contained within the external surfaces of a fire compartment.

6
New cards

Compartment volume

The volume of the portion of a building contained within the external surfaces of the walls and floors forming a fire compartment.

7
New cards

Cubical extent

The space contained within the external surfaces of the walls and roof of a building and the upper surface of the floor of its lowest storey, excluding spaces within roof enclosures used exclusively for water tanks, lift gear, or other services.

8
New cards

Deadend travel distance

The overall length of travel within an exit route before an alternative exit is available.

9
New cards

Discharge value

The number of persons that a staircase of a given width may be assumed to be capable of discharging from a given number of storeys.

10
New cards

Element of construction

Any floor, beam, column, or hanger; any loadbearing wall or member (other than roof members); or any required staircase including its landings and supports.

11
New cards

Emergency Vehicular Access (EVA)

A vehicular access designed and constructed to allow safe and unobstructed access and operation of Fire Services Department vehicles to a building in the event of a fire or other emergency.

12
New cards

Exit door

A door from a storey, flat, or room that provides direct access on to an exit route.

13
New cards

Exit route

The continuous path of travel from any part of a building to the ultimate place of safety, excluding revolving doors, lifts, and escalators.

14
New cards

Fire barrier

A construction having a specified fire resistance rating (FRR) that separates one space from another and may form part of a fire compartment.

15
New cards

Fire compartment

A space enclosed by fire barriers or appropriate construction on all sides so that fire will not spread out from the space or into an adjoining space.

16
New cards

Firefighting and rescue stairway

A specialized stairway enclosure that accommodates both an access staircase and a fireman's lift.

17
New cards

Fire resistance rating (FRR)

The period of time a building element is capable of resisting the action of fire across three standard performance criteria: stability (XX), integrity (YY), and insulation (ZZ), expressed as X/Y/ZX/Y/Z in minutes.

18
New cards

Fireman's lift

A lift specifically designed, installed, and designated to be operated by firefighters during a fire incident.

19
New cards

Maisonette

A separate and self-contained flat (not being a tenement floor) comprising more than one but not more than three storeys.

20
New cards

Occupant capacity

The maximum number of persons that a room, storey, or fire compartment is calculated to accommodate based on specified occupancy factors.

21
New cards

Passive fire safety provisions

Permanent structural and architectural features—such as fire barriers, fire doors, spandrels, and non-combustible linings—that prevent fire development and flame/smoke spread without requiring activation.

22
New cards

Protected exit

A required staircase, ramp, or passageway completely enclosed by fire barriers that leads to an ultimate place of safety.

23
New cards

Protected lobby

A lobby constructed with fire and smoke resisting enclosures to prevent the penetration and spread of heat and smoke.

24
New cards

Refuge floor

A protected, naturally ventilated intermediate floor serving as a temporary safe assembly area for occupants of tall buildings during evacuation before reaching an ultimate place of safety.

25
New cards

Required staircase

An access staircase, whether inside a firefighting and rescue stairway or not, or any staircase required by code for occupant escape in case of fire.

26
New cards

Smoke seal

A flexible or intumescent sealing component installed around openings (doors, dampers, or penetrations) to inhibit the leakage and passage of smoke between adjoining spaces.

27
New cards

Special hazard

An area within a building presenting a high risk of fire ignition, rapid spread, or explosion (e.g., transformer rooms, boiler rooms, generator rooms, and dangerous goods stores) that requires enhanced separation.

28
New cards

Travel distance

The horizontal distance measured along the centerline of the exit route from the most remote point on a floor to the protected exit door, the first stair tread, or a final discharge point.

29
New cards

Ultimate place of safety

A street or open exterior space connected directly to a street, having a clear width of not less than 1.5 m1.5\,\text{m} or the required exit route width, where evacuees can safely disperse clear of the effects of fire.

30
New cards

Usable floor area

The aggregate area of floors in a storey or building excluding staircases, public circulation spaces, lift landings, lavatories, and machinery spaces.

31
New cards

Ventilated staircase

A staircase where at least 50%50\% of its perimeter is open to the external air (at least 50%50\% on the long face and 25%25\% on other faces) to provide continuous natural cross-ventilation.

32
New cards

Temporary refuge space

A designated safe space of at least 1.5 m×1.5 m1.5\,\text{m} \times 1.5\,\text{m} (or two spaces of 0.75 m×1.5 m0.75\,\text{m} \times 1.5\,\text{m}) provided in protected exits or fireman's lift lobbies where persons with a disability can await rescue.

33
New cards

Flashover

The rapid transition from a localized developing fire to full room involvement where all exposed combustible surfaces ignite simultaneously, typically associated with ceiling temperatures around 600 ∘C600\,^\circ\text{C} and floor radiation over 20 kW/m220\,\text{kW/m}^2.

34
New cards

Available Safe Egress Time (ASET)

The calculated time interval between fire ignition and the point at which conditions inside the enclosure reach untenable limits for occupants.

35
New cards

Required Safe Egress Time (RSET)

The total time needed for occupants to safely evacuate to a place of safety, consisting of fire detection time, warning cue, pre-movement time, and physical travel time.

36
New cards

Pre-movement time

The period between the recognition of a fire alarm or warning cue and the moment occupants actually initiate movement toward an exit.

37
New cards

Design fire

An engineering characterization of an idealized fire's development over time, specified as a curve of heat release rate (HRR) versus time, used as the test load in fire engineering assessments.

38
New cards

Spandrel

A vertical fire-resisting wall element of at least 900 mm900\,\text{mm} in height (or an equivalent 500 mm500\,\text{mm} horizontal projection) installed between windows on successive storeys to impede external vertical fire spread.

39
New cards
<p>Phases of Fire Development Curve</p>

Phases of Fire Development Curve

The chronological progression of an enclosure fire through five stages: Incipient phase, Growth phase (t2t^2 development), Flashover transition, Fully Developed phase, and Decay phase.

40
New cards
<p>Timeline Assessment (ASET vs. RSET)</p>

Timeline Assessment (ASET vs. RSET)

A fire safety engineering evaluation method comparing Available Safe Egress Time (ASET) to Required Safe Egress Time (RSET) to ensure an adequate safety margin exists before tenability limits are reached.

41
New cards
<p>Vertical Barrier at Opening</p>

Vertical Barrier at Opening

A non-combustible downstand barrier of at least 450 mm450\,\text{mm} hanging below the ceiling or floor slab around floor voids and escalators to trap a buoyant hot smoke layer and trigger sprinkler activation.