1/121
Looks like no tags are added yet.
2,000 years ago
YEAR
Discovery of magnets by the Romans
Nikola Tesla
Discovered the rotating magnetic field in Budapest in 1882
Isidor Rabi
Detected NMR absorption in a molecular beam in 1938
Isidor Rabi
Awarded the 1955 Nobel Prize in Physics for determining nuclear magnetic moments
Felix Bloch
Detected nuclear induction signals in water in 194
Edward Purcell
Detected NMR absorption in paraffin in 1945
Tesla (T)
SI unit of magnetic field strength named in honor of Nikola Tesla
Paul Lauterbur
Coined "zeugmatography" and published the 1973 cross-sectional NMR capillary image
Projectional NMR tomography (zeugmatography)
Paul Lauterbur's primary documented contribution to MRI
Use of a field gradient for slice selection
Sir Peter Mansfield's primary recognized contribution to early MRI developmen
Paul Lauterbur and Sir Peter Mansfield
Shared the 2003 Nobel Prize in Physiology or Medicine for MRI discoveries
Raymond Damadian
Constructed the first full-body human MR scanner named "Indomitable”
Field-focused NMR (FONAR)
Damadian's original name for his imaging method and commercial company
State University of New York Brooklyn
Dr. Raymond Damadian's institutional affiliation during his pioneering work
July 3, 1977
Exact date Raymond Damadian and his team demonstrated the first human head scan
1977
Year the first MRI examination was performed in a human being
The 1970s
Decade when NMRI was renamed MRI to remove negative connotations of "nuclear"
Feared exposure to harmful radioactive radiation
Reason patients experienced anxiety over the early term "nuclear magnetic resonance"
1982
Year the first brain head image at 0.1 T using back-projection was published
Charles Dumoulin
Perfected MR angiography (MRA) in the year 1987
1993
Year functional MRI (fMRI) was developed using echo planar imaging to map brain regions
Magnetic Resonance Imaging
What the acronym MRI stands for
Gauss (G)
CGS unit for magnetic field strength
Tesla (T)
SI unit for magnetic field strength
10,000 Gauss
Number of Gauss equivalent to 1 Tesla
50 μT or 0.5 G
Approximate strength of the Earth's magnetic field
Non-ionizing radiation (RF)
Type of radiation utilized in MRI that does not ionize atoms
20 keV – 150 keV
Energy/frequency range of diagnostic x-rays in the electromagnetic spectrum
10 – 300 MHz
Typical frequency range of radiofrequency (RF) used in clinical MRI systems
Imaging window
Term describing a range within the electromagnetic spectrum used to produce images
Hydrogen (Proton / 1H)
Atomic nucleus most commonly utilized in clinical MRI due to high abundance
80%
Percentage of all atoms in the human body made up by hydrogen
Spin (angular momentum)
Primary physical property allowing hydrogen nuclei to behave like tiny bar magnets
Larmor equation
Fundamental equation defining precessional frequency (ω0 = γ · B0)
Precessional or Larmor frequency
Meaning of ω0 in the Larmor equation
Gyromagnetic ratio
Meaning of γ (gamma) in the Larmor equation
External / main static magnetic field strength
Meaning of B0 in the Larmor equation / main static magnetic field designation
Precession
Wobble of a spinning body's rotational axis about a stationary axis describing a cone
Resonance
Vibration in a system caused by a periodic stimulus near its natural frequency
Magnetic moment (μ)
Force created when a magnetic dipole is placed in a magnetic field
Z-axis
Axis conventionally chosen to point in the direction of B0 in vector diagrams
Longitudinal magnetization (Mz)
Net magnetization vector aligned parallel to the main magnetic field
Transverse magnetization (Mxy)
Net magnetization in the transverse plane (XY plane)
Spin of atoms / nuclei
What an MRI system uses an RF pulse to change
Fourier transform (FT)
Mathematical transformation used to convert raw MR data into an image / spectrum
Spin-lattice (longitudinal / thermal) relaxation
Synonyms for T1 relaxation time
63%
Recovery of longitudinal magnetization (Mz) after one T1 time constant
Spin-spin (transverse) relaxation
Synonyms for T2 relaxation time
37%
Level to which transverse magnetization (Mxy) falls after one T2 time constant
T2 relaxation
Which relaxation process occurs much faster: T1 or T2?
T2* (T2 star)
Relaxation constant shortened compared to T2 due to magnetic field inhomogeneities
Spin density (SD) / Proton density (PD)
Concentration of mobile hydrogen nuclei contributing to the MRI signal
Repetition Time (TR)
Time between two successive 90° excitation pulses
Echo Time (TE)
Time between the initial 90° RF pulse and the resulting spin echo signal
Short TR and short TE
TR and TE combination for T1-weighted image contrast
Long TR and long TE
TR and TE combination for T2-weighted image contrast
Long TR and short TE
TR and TE combination for Proton Density (Spin Density) weighted contrast
Short TE: < 30 ms | Long TR: > 1500 ms
Typical clinical values for "short TE" and "long TR"
Bright / Hyperintense
Appearance of short-T1 tissues (e.g., fat) on a T1-weighted image
Bright on T1; dark/lower signal on T2
Appearance of fat on a T1-weighted image vs. a T2-weighted image
Dark on T1; bright/lighter on T2
Appearance of cerebrospinal fluid (CSF) on T1-weighted vs. T2 weighted images
Fat, hemangioma, methemoglobin, proteinaceous cysts, subacute hemorrhage
Tissues/pathologies exhibiting high signal (bright) on T1-weighted images
CSF, synovial fluid, infection, inflammation, edema, cysts
Tissues/pathologies exhibiting high signal (bright) on T2-weighted images
Cortical bone, avascular necrosis (AVN), infarction, scar tissue
Structures displaying low signal (dark) on T1-weighted images
Cortical bone, bone islands, deoxyhemoglobin, hemosiderin, calcification
Structures displaying low signal (dark) on T2-weighted images
Air, fast-flowing blood, ligaments, tendons, cortical bone, scar tissue, calcification
Structures giving no signal (completely black) on both T1 and T2 (including air on T2)
Tarlov cyst
CSF-filled nerve root cysts most common in the lumbosacral area
Permanent, resistive, and superconducting magnets
Three primary types of magnets used in MRI systems
Superconducting magnet
Most common magnet design in modern high-field clinical scanners (1.5T and 3.0T)
Philips Multiva 1.5T
Name and field strength of the DLSUMC MRI machine
Alnico
1930s aluminum-nickel-cobalt alloy used for permanent magnets (up to 0.3 T)
Mechanically adjusting the two finely machined pole pieces
How homogeneity is adjusted in permanent magnets lacking electronic shim coils
Water (heat exchanger)
Cooling system required for resistive electromagnet MRI systems
Niobium-titanium (NbTi)
Specific metal alloy most commonly used in clinical superconducting electromagnets
Liquid helium (4.2 K) and liquid nitrogen (77 K)
Cryogenic liquids maintaining superconducting temperatures (innermost vs. outermost)
Quench
Sudden loss of superconductivity causing rapid boil-off/venting of cryogen liquid
Shim coils, gradient coils, and RF coils
Three main components categorized under secondary coils
Shimming (DSV = Diameter of Spherical Volume)
Process of making B0 homogeneous (measured in ppm over DSV)
Spatial encoding (choosing exact body slice location)
Core function of gradient magnetic coils (typical strength: 1 – 10 mT/m)
Z-coil (Axial); Y-coil (Coronal/phase); X-coil (Sagittal/readout)
Gradient coils used for Axial, Coronal, and Sagittal slice selection
Oblique slice
Slice produced when all three gradient coils (X, Y, and Z) are energized simultaneously
Saddle coil (early); Quadrature coil (birdcage resonator)
High-frequency AC (10–80 MHz) probe designs: early vs. "birdcage resonator"
40% improvement (√2)
SNR improvement offered by a quadrature coil compared to a linear coil
Volume coils vs. Surface coils (and Phased-array / synergy coils)
Homogeneous whole-part coils vs. high-resolution local inhomogeneous coils
At right angles to B0; closest to patient inside gradient coils
Position of RF receive coils relative to B0 and internal bore placement
Faraday cage
RF-shielded room enclosure constructed of copper wire mesh or copper plates
Passive shielding vs. Active shielding (self-shielded)
Iron-plate wall lining vs. built-in magnet bucking coils for magnetic shielding
18°C to 20°C; relative humidity ≤ 40%
Recommended HVAC temperature and relative humidity for an MRI scanner room
Saturation Recovery (SR)
Early pulse sequence using 90°-90°-90° pulses (rarely used today)
Inversion Recovery (IR)
Pulse sequence always starting with a 180° pulse (180°-90°-180° pattern)
STIR (fat suppression) vs. FLAIR (Fluid-Attenuated Inversion Recovery)
IR sequence designed to suppress fat signal vs. null CSF signal
Spin Echo (SE) / Carr-Purcell Meiboom-Gill (CPMG) sequence
Most frequently used clinical pulse sequence (90° and 180° pulses) and its synonym
Strong signal, less artifact; longer scan time & higher SAR
Primary advantages and disadvantages of Spin Echo over Gradient Echo
Gradient Refocused Echo (GRE)
Sequence using flip angle < 90° and gradient reversal instead of a 180° pulse
Coherent maintains residual transverse magnetization; Incoherent spoils it for T1
Coherent (Rewind) GRE vs. Incoherent (Spoiled) GRE characteristics
High FA + short TE (T1); Low FA + long TE (T2*)
GE flip angle (FA) and TE combinations for T1-weighted vs. T2* weighted contrast
Fast Spin Echo,
Turbo Spin Echo,
Fast Field Echo,
Steady-State Free Precession,
Susceptibility Weighted Imaging,
Fast Imaging Employing Steady-State Acquisition
Key sequence acronyms:
FSE,
TSE,
FFE,
SSFP,
SWI,
FIESTA
Time-of-Flight (TOF) MRA
Techniques deriving contrast between stationary tissues and flowing blood
SPAIR vs. Dixon technique
Fat suppression combining IR + fat sat vs. in-phase/out-of-phase separation
Increases SNR; NEX/NSA proportionally increases scan time
Effects of increasing TR or NEX/NSA on SNR and scan time