1
New cards

2,000 years ago

YEAR

Discovery of magnets by the Romans

2
New cards

Nikola Tesla

Discovered the rotating magnetic field in Budapest in 1882

3
New cards

Isidor Rabi

Detected NMR absorption in a molecular beam in 1938

4
New cards

Isidor Rabi

Awarded the 1955 Nobel Prize in Physics for determining nuclear magnetic moments

5
New cards

Felix Bloch

Detected nuclear induction signals in water in 194

6
New cards

Edward Purcell

Detected NMR absorption in paraffin in 1945

7
New cards

Tesla (T)

SI unit of magnetic field strength named in honor of Nikola Tesla

8
New cards

Paul Lauterbur

Coined "zeugmatography" and published the 1973 cross-sectional NMR capillary image

9
New cards

Projectional NMR tomography (zeugmatography)

Paul Lauterbur's primary documented contribution to MRI

10
New cards

Use of a field gradient for slice selection

Sir Peter Mansfield's primary recognized contribution to early MRI developmen

11
New cards

Paul Lauterbur and Sir Peter Mansfield

Shared the 2003 Nobel Prize in Physiology or Medicine for MRI discoveries

12
New cards

Raymond Damadian

Constructed the first full-body human MR scanner named "Indomitable”

13
New cards

Field-focused NMR (FONAR)

Damadian's original name for his imaging method and commercial company

14
New cards

State University of New York Brooklyn

Dr. Raymond Damadian's institutional affiliation during his pioneering work

15
New cards

July 3, 1977

Exact date Raymond Damadian and his team demonstrated the first human head scan

16
New cards

1977

Year the first MRI examination was performed in a human being

17
New cards

The 1970s

Decade when NMRI was renamed MRI to remove negative connotations of "nuclear"

18
New cards

Feared exposure to harmful radioactive radiation

Reason patients experienced anxiety over the early term "nuclear magnetic resonance"

19
New cards

1982

Year the first brain head image at 0.1 T using back-projection was published

20
New cards

Charles Dumoulin

Perfected MR angiography (MRA) in the year 1987

21
New cards

1993

Year functional MRI (fMRI) was developed using echo planar imaging to map brain regions

22
New cards

Magnetic Resonance Imaging

What the acronym MRI stands for

23
New cards

Gauss (G)

CGS unit for magnetic field strength

24
New cards

Tesla (T)

SI unit for magnetic field strength

25
New cards

10,000 Gauss

Number of Gauss equivalent to 1 Tesla

26
New cards

50 μT or 0.5 G

Approximate strength of the Earth's magnetic field

27
New cards

Non-ionizing radiation (RF)

Type of radiation utilized in MRI that does not ionize atoms

28
New cards

20 keV – 150 keV

Energy/frequency range of diagnostic x-rays in the electromagnetic spectrum

29
New cards

10 – 300 MHz

Typical frequency range of radiofrequency (RF) used in clinical MRI systems

30
New cards

Imaging window

Term describing a range within the electromagnetic spectrum used to produce images

31
New cards

Hydrogen (Proton / 1H)

Atomic nucleus most commonly utilized in clinical MRI due to high abundance

32
New cards

80%

Percentage of all atoms in the human body made up by hydrogen

33
New cards

Spin (angular momentum)

Primary physical property allowing hydrogen nuclei to behave like tiny bar magnets

34
New cards

Larmor equation

Fundamental equation defining precessional frequency (ω0 = γ · B0)

35
New cards

Precessional or Larmor frequency

Meaning of ω0 in the Larmor equation

36
New cards

Gyromagnetic ratio

Meaning of γ (gamma) in the Larmor equation

37
New cards

External / main static magnetic field strength

Meaning of B0 in the Larmor equation / main static magnetic field designation

38
New cards

Precession

Wobble of a spinning body's rotational axis about a stationary axis describing a cone

39
New cards

Resonance

Vibration in a system caused by a periodic stimulus near its natural frequency

40
New cards

Magnetic moment (μ)

Force created when a magnetic dipole is placed in a magnetic field

41
New cards

Z-axis

Axis conventionally chosen to point in the direction of B0 in vector diagrams

42
New cards

Longitudinal magnetization (Mz)

Net magnetization vector aligned parallel to the main magnetic field

43
New cards

Transverse magnetization (Mxy)

Net magnetization in the transverse plane (XY plane)

44
New cards

Spin of atoms / nuclei

What an MRI system uses an RF pulse to change

45
New cards

Fourier transform (FT)

Mathematical transformation used to convert raw MR data into an image / spectrum

46
New cards

Spin-lattice (longitudinal / thermal) relaxation

Synonyms for T1 relaxation time

47
New cards

63%

Recovery of longitudinal magnetization (Mz) after one T1 time constant

48
New cards

Spin-spin (transverse) relaxation

Synonyms for T2 relaxation time

49
New cards

37%

Level to which transverse magnetization (Mxy) falls after one T2 time constant

50
New cards

T2 relaxation

Which relaxation process occurs much faster: T1 or T2?

51
New cards

T2* (T2 star)

Relaxation constant shortened compared to T2 due to magnetic field inhomogeneities

52
New cards

Spin density (SD) / Proton density (PD)

Concentration of mobile hydrogen nuclei contributing to the MRI signal

53
New cards

Repetition Time (TR)

Time between two successive 90° excitation pulses

54
New cards

Echo Time (TE)

Time between the initial 90° RF pulse and the resulting spin echo signal

55
New cards

Short TR and short TE

TR and TE combination for T1-weighted image contrast

56
New cards

Long TR and long TE

TR and TE combination for T2-weighted image contrast

57
New cards

Long TR and short TE

TR and TE combination for Proton Density (Spin Density) weighted contrast

58
New cards

Short TE: < 30 ms | Long TR: > 1500 ms

Typical clinical values for "short TE" and "long TR"

59
New cards

Bright / Hyperintense

Appearance of short-T1 tissues (e.g., fat) on a T1-weighted image

60
New cards

Bright on T1; dark/lower signal on T2

Appearance of fat on a T1-weighted image vs. a T2-weighted image

61
New cards

Dark on T1; bright/lighter on T2

Appearance of cerebrospinal fluid (CSF) on T1-weighted vs. T2 weighted images

62
New cards

Fat, hemangioma, methemoglobin, proteinaceous cysts, subacute hemorrhage

Tissues/pathologies exhibiting high signal (bright) on T1-weighted images

63
New cards

CSF, synovial fluid, infection, inflammation, edema, cysts

Tissues/pathologies exhibiting high signal (bright) on T2-weighted images

64
New cards

Cortical bone, avascular necrosis (AVN), infarction, scar tissue

Structures displaying low signal (dark) on T1-weighted images

65
New cards

Cortical bone, bone islands, deoxyhemoglobin, hemosiderin, calcification

Structures displaying low signal (dark) on T2-weighted images

66
New cards

Air, fast-flowing blood, ligaments, tendons, cortical bone, scar tissue, calcification

Structures giving no signal (completely black) on both T1 and T2 (including air on T2)

67
New cards

Tarlov cyst

CSF-filled nerve root cysts most common in the lumbosacral area

68
New cards

Permanent, resistive, and superconducting magnets

Three primary types of magnets used in MRI systems

69
New cards

Superconducting magnet

Most common magnet design in modern high-field clinical scanners (1.5T and 3.0T)

70
New cards

Philips Multiva 1.5T

Name and field strength of the DLSUMC MRI machine

71
New cards

Alnico

1930s aluminum-nickel-cobalt alloy used for permanent magnets (up to 0.3 T)

72
New cards

Mechanically adjusting the two finely machined pole pieces

How homogeneity is adjusted in permanent magnets lacking electronic shim coils

73
New cards

Water (heat exchanger)

Cooling system required for resistive electromagnet MRI systems

74
New cards

Niobium-titanium (NbTi)

Specific metal alloy most commonly used in clinical superconducting electromagnets

75
New cards

Liquid helium (4.2 K) and liquid nitrogen (77 K)

Cryogenic liquids maintaining superconducting temperatures (innermost vs. outermost)

76
New cards

Quench

Sudden loss of superconductivity causing rapid boil-off/venting of cryogen liquid

77
New cards

Shim coils, gradient coils, and RF coils

Three main components categorized under secondary coils

78
New cards

Shimming (DSV = Diameter of Spherical Volume)

Process of making B0 homogeneous (measured in ppm over DSV)

79
New cards

Spatial encoding (choosing exact body slice location)

Core function of gradient magnetic coils (typical strength: 1 – 10 mT/m)

80
New cards

Z-coil (Axial); Y-coil (Coronal/phase); X-coil (Sagittal/readout)

Gradient coils used for Axial, Coronal, and Sagittal slice selection

81
New cards

Oblique slice

Slice produced when all three gradient coils (X, Y, and Z) are energized simultaneously

82
New cards

Saddle coil (early); Quadrature coil (birdcage resonator)

High-frequency AC (10–80 MHz) probe designs: early vs. "birdcage resonator"

83
New cards

40% improvement (√2)

SNR improvement offered by a quadrature coil compared to a linear coil

84
New cards

Volume coils vs. Surface coils (and Phased-array / synergy coils)

Homogeneous whole-part coils vs. high-resolution local inhomogeneous coils

85
New cards

At right angles to B0; closest to patient inside gradient coils

Position of RF receive coils relative to B0 and internal bore placement

86
New cards

Faraday cage

RF-shielded room enclosure constructed of copper wire mesh or copper plates

87
New cards

Passive shielding vs. Active shielding (self-shielded)

Iron-plate wall lining vs. built-in magnet bucking coils for magnetic shielding

88
New cards

18°C to 20°C; relative humidity ≤ 40%

Recommended HVAC temperature and relative humidity for an MRI scanner room

89
New cards

Saturation Recovery (SR)

Early pulse sequence using 90°-90°-90° pulses (rarely used today)

90
New cards

Inversion Recovery (IR)

Pulse sequence always starting with a 180° pulse (180°-90°-180° pattern)

91
New cards

STIR (fat suppression) vs. FLAIR (Fluid-Attenuated Inversion Recovery)

IR sequence designed to suppress fat signal vs. null CSF signal

92
New cards

Spin Echo (SE) / Carr-Purcell Meiboom-Gill (CPMG) sequence

Most frequently used clinical pulse sequence (90° and 180° pulses) and its synonym

93
New cards

Strong signal, less artifact; longer scan time & higher SAR

Primary advantages and disadvantages of Spin Echo over Gradient Echo

94
New cards

Gradient Refocused Echo (GRE)

Sequence using flip angle < 90° and gradient reversal instead of a 180° pulse

95
New cards

Coherent maintains residual transverse magnetization; Incoherent spoils it for T1

Coherent (Rewind) GRE vs. Incoherent (Spoiled) GRE characteristics

96
New cards

High FA + short TE (T1); Low FA + long TE (T2*)

GE flip angle (FA) and TE combinations for T1-weighted vs. T2* weighted contrast

97
New cards

Fast Spin Echo,

Turbo Spin Echo,

Fast Field Echo,

Steady-State Free Precession,

Susceptibility Weighted Imaging,

Fast Imaging Employing Steady-State Acquisition

Key sequence acronyms:

FSE,

TSE,

FFE,

SSFP,

SWI,

FIESTA

98
New cards

Time-of-Flight (TOF) MRA

Techniques deriving contrast between stationary tissues and flowing blood

99
New cards

SPAIR vs. Dixon technique

Fat suppression combining IR + fat sat vs. in-phase/out-of-phase separation

100
New cards

Increases SNR; NEX/NSA proportionally increases scan time

Effects of increasing TR or NEX/NSA on SNR and scan time