Light transmission test
• UV-Vis Spectrophotometer
• Limits: maximum % light transmission at wavelength 290 450nm
• Only for light-resistant containers
Chemical resistance test
• Determines the resistance of new glass containers to water attack
• Degree of attack is measured in terms of amount of alkali released from the glass
Direct acidimetry
trituration technique for chemical tesistance test
Direct acidimetry
Indicator: methyl orange
Red – acidic
Yellow - basic
Types I, III and NP
Pulverized with the addition of water, then autoclaved
Type II is not applicable as it is a treated type of glass, it would make it the same as type III.
Water Attack at 121˚
Type II
It is analyzed as a whole and not in pieces
Placed in water and autoclaved
Permeation
• Determines the moisture permeability of a container
• Initial weights, final weights and volume of containers are determined to compute for rate moisture permeability (mg/d/L)
12 bottles
Sample size for permeation
Anhydrous CaCl2
10 test containers with desiccant
glass beads
2 control containers with
20 ± 20ºC, 75 ± 3% RH
In permeation, it is stored for 14 days at _____
o The relative humidity inside the desiccator is maintained by adding a solution (saturated NaCl solution)
Heavy metals
• Titrimetry (complexometry)
• Instrument method of analysis: AAS (HCL + Metal)
Nonvolatile residue
• Gravimetric method
Thermal analysis
DSC thermogram
Residue-on-ignition (ROI)
• Gravimetric method
Buffering capacity
• Potentiometric titration
In vitro
• determines the biological reactivity of mammalian cell cultures following contact with elastomeric plastics and other polymeric materials with direct or indirect contact or of specific extracts prepared from the materials being tested
o When we say biological reactivity, it means the allergic reaction of our closure or packaging components to the mammalian cells.
Agar diffusion test
• designed for elastomeric closures in variety of shapes
• agar layer acts as cushion to protect the cells from mechanical damage, while allowing the diffusion of leachable chemicals from the polymeric substances
Direct contact test
• designed for materials in a variety of shapes
• allows for simultaneous extraction and testing of leachable chemicals from specimen with serum-supplemented medium
• not appropriate for very low- or high-density materials that could cause mechanical damage to the cells
Elution test
• designed for the evaluation of extracts of polymeric materials
• allows extraction of the specimen at physiological or non physiological temperatures for varying time intervals
• appropriate for high-density materials and for dose response evaluations
In vivo
• designed to determine the biological response of animals to elastomerics, plastics and other polymeric materials with direct or indirect patient contact, or by injection of specific extracts prepared from the sample
o Does not use mammalian cell culture. Rather, it will be injected on animals.
Systemic injection test
designed to evaluate systemic responses to the extracts or materials under test following injection into the mice
Intracutaneous test
designed to evaluate local responses to the extracts of materials under test following intracutaneous injection into rabbits
Implantation test
designed for the evaluation of plastic materials and other polymeric materials in direct contact with living tissue
o Implantation of the plastic material to the animal