Z87 Goggles
Eye protection equipment meeting specific flammability and chemical resistance requirements that must be worn by all persons in the laboratory and cannot contain open perforations.
Personal Protective Attire
Required laboratory clothing consisting of a lab coat, shoes that completely cover the foot, and tied-back long hair, while strictly avoiding floppy sleeves and shorts.
Chemical Protective Gloves
Protective hand coverings made of materials such as vinyl, latex, or nitrile that must be selected based on specific chemical hazards and never worn outside the laboratory.
Safety Eyewash
Emergency station used to flush chemicals from the eyes by positioning the head with eyes open between the spigots and flushing continuously for a minimum standard of 15minutes.
Safety Shower
Emergency equipment used to rinse chemical spills off a person's body after removing all contaminated clothing, requiring washing for at least 15−20minutes.
Fire Blanket
Emergency safety equipment removed from its container using straps and wrapped completely around an individual to smother clothing fires.
Carbon Dioxide Fire Extinguisher
Extinguisher suitable for general chemistry laboratory fires that operates by aiming the nozzle at the base of the fire, pulling the locking key, and depressing the handles together.
Emergency Gas/Electrical Shut-Off
A central control system consisting of a single valve and circuit breaker assembly that completely shuts off gas supply and electrical power to laboratory outlets.
Sodium Bicarbonate
A benchtop chemical powder used to neutralize and cover liquid acid spills prior to disposal.
Ansul
A solid extinguishing powder stored on laboratory benches used specifically for extinguishing metal fires.
Broken Glassware Crock
A designated disposal container for broken or single-use glassware that must only receive items after all disposable contents have been removed.
Chemical Waste Bottles
Dedicated disposal containers located in the fume hood for specific solid and liquid chemical wastes, ensuring chemicals are never poured down the drain.
Material Safety Data Sheets (MSDS)
Documents providing detailed hazard, handling, and safety information for specific chemicals, accessible on regulation placards or through university environmental safety links.
Exact Number
A number obtained by direct counting (e.g., 2soccer balls) or by definition (e.g., 1m=100cm) that possesses no uncertainty and an infinite number of significant figures.
Measured Number
A number obtained using a measuring instrument (such as a ruler, balance, or cylinder) that inherently contains experimental uncertainty in its final digit.
Accuracy
A quantitative measure of how closely a measured experimental value agrees with the true or accepted reference value.
Precision
A measure of the reproducibility and agreement among a set of experimental measurements performed under the same conditions.
Significant Figures
All the certain digits recorded from the calibration marks of a measuring device plus the first uncertain, estimated digit.
Addition and Subtraction Rule (Significant Figures)
The mathematical guideline stating that the final result must be rounded to the same number of decimal places as the measurement having the fewest decimal places.
Multiplication and Division Rule (Significant Figures)
The mathematical guideline stating that the final calculated answer must be rounded to match the fewest significant figures of any factor in the calculation.
Scientific Notation
A standardized form of expressing numerical values as a×10n, where 1≤a<10 and n is an integer, retaining only significant figures.
Uncertainty of Graduated Glassware
The experimental reading uncertainty calculated by taking the smallest scale division of the glassware and dividing by two (2Smallest division).
Uncertainty of Digital Balances
The measurement uncertainty of a digital readout, established by placing a 1 in the last displayed decimal place (e.g., ±0.0001g).
Meniscus
The curved upper boundary surface of a liquid column, which must be read horizontally at its lowest point at eye level to prevent parallax error.
Density
An intensive physical property representing the ratio of a substance's mass to its occupied volume (Density=VolumeMass).
Volume Displacement
A technique used to determine the volume of an irregular solid by measuring the volume of liquid it displaces when submerged in a graduated cylinder.
Volumetric Flask
A flat-bottomed glassware piece with an elongated neck and a precise calibration line, engineered to hold an exact known volume of liquid at a designated temperature.
Vernier Caliper
A precision mechanical tool featuring a fixed main scale and an aligned sliding scale used to measure external dimensions, internal dimensions, and depths.
Outside Jaws
The prominent lower jaws of a vernier caliper designed specifically for clamping and measuring external widths or outer diameters of objects.
Inside Jaws
The smaller upper jaws of a vernier caliper used to reach inside an object to measure internal diameters or hole widths.
Retainer (Setscrew)
A locking screw on a vernier caliper that fastens the movable sliding scale in place to allow easy reading and measurement transfer.
Density Replicate Agreement Criterion
The experimental quality benchmark requiring trial densities of an unknown substance to agree within 1% to calculate an average; otherwise, a third trial is mandated.