General Chemistry Laboratory Safety, Measurement, and Density

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/31

flashcard set

Earn XP

Description and Tags

Comprehensive vocabulary flashcards covering general chemistry laboratory safety rules, personal protective equipment, emergency protocols, scientific notation, significant figures, measurement uncertainty, volumetric measurements, vernier caliper operation, and density determinations.

32 Terms

1
New cards

Z87 Goggles

Eye protection equipment meeting specific flammability and chemical resistance requirements that must be worn by all persons in the laboratory and cannot contain open perforations.

2
New cards

Personal Protective Attire

Required laboratory clothing consisting of a lab coat, shoes that completely cover the foot, and tied-back long hair, while strictly avoiding floppy sleeves and shorts.

3
New cards

Chemical Protective Gloves

Protective hand coverings made of materials such as vinyl, latex, or nitrile that must be selected based on specific chemical hazards and never worn outside the laboratory.

4
New cards

Safety Eyewash

Emergency station used to flush chemicals from the eyes by positioning the head with eyes open between the spigots and flushing continuously for a minimum standard of 15 minutes15\,\text{minutes}.

5
New cards

Safety Shower

Emergency equipment used to rinse chemical spills off a person's body after removing all contaminated clothing, requiring washing for at least 15−20 minutes15-20\,\text{minutes}.

6
New cards

Fire Blanket

Emergency safety equipment removed from its container using straps and wrapped completely around an individual to smother clothing fires.

7
New cards

Carbon Dioxide Fire Extinguisher

Extinguisher suitable for general chemistry laboratory fires that operates by aiming the nozzle at the base of the fire, pulling the locking key, and depressing the handles together.

8
New cards

Emergency Gas/Electrical Shut-Off

A central control system consisting of a single valve and circuit breaker assembly that completely shuts off gas supply and electrical power to laboratory outlets.

9
New cards

Sodium Bicarbonate

A benchtop chemical powder used to neutralize and cover liquid acid spills prior to disposal.

10
New cards

Ansul

A solid extinguishing powder stored on laboratory benches used specifically for extinguishing metal fires.

11
New cards

Broken Glassware Crock

A designated disposal container for broken or single-use glassware that must only receive items after all disposable contents have been removed.

12
New cards

Chemical Waste Bottles

Dedicated disposal containers located in the fume hood for specific solid and liquid chemical wastes, ensuring chemicals are never poured down the drain.

13
New cards

Material Safety Data Sheets (MSDS)

Documents providing detailed hazard, handling, and safety information for specific chemicals, accessible on regulation placards or through university environmental safety links.

14
New cards

Exact Number

A number obtained by direct counting (e.g., 2 soccer balls2\,\text{soccer balls}) or by definition (e.g., 1 m=100 cm1\,\text{m} = 100\,\text{cm}) that possesses no uncertainty and an infinite number of significant figures.

15
New cards

Measured Number

A number obtained using a measuring instrument (such as a ruler, balance, or cylinder) that inherently contains experimental uncertainty in its final digit.

16
New cards

Accuracy

A quantitative measure of how closely a measured experimental value agrees with the true or accepted reference value.

17
New cards

Precision

A measure of the reproducibility and agreement among a set of experimental measurements performed under the same conditions.

18
New cards

Significant Figures

All the certain digits recorded from the calibration marks of a measuring device plus the first uncertain, estimated digit.

19
New cards

Addition and Subtraction Rule (Significant Figures)

The mathematical guideline stating that the final result must be rounded to the same number of decimal places as the measurement having the fewest decimal places.

20
New cards

Multiplication and Division Rule (Significant Figures)

The mathematical guideline stating that the final calculated answer must be rounded to match the fewest significant figures of any factor in the calculation.

21
New cards

Scientific Notation

A standardized form of expressing numerical values as a×10na \times 10^n, where 1≤a<101 \le a < 10 and nn is an integer, retaining only significant figures.

22
New cards

Uncertainty of Graduated Glassware

The experimental reading uncertainty calculated by taking the smallest scale division of the glassware and dividing by two (Smallest division2\frac{\text{Smallest division}}{2}).

23
New cards

Uncertainty of Digital Balances

The measurement uncertainty of a digital readout, established by placing a 11 in the last displayed decimal place (e.g., ±0.0001 g\pm 0.0001\,\text{g}).

24
New cards

Meniscus

The curved upper boundary surface of a liquid column, which must be read horizontally at its lowest point at eye level to prevent parallax error.

25
New cards

Density

An intensive physical property representing the ratio of a substance's mass to its occupied volume (Density=MassVolume\text{Density} = \frac{\text{Mass}}{\text{Volume}}).

26
New cards

Volume Displacement

A technique used to determine the volume of an irregular solid by measuring the volume of liquid it displaces when submerged in a graduated cylinder.

27
New cards

Volumetric Flask

A flat-bottomed glassware piece with an elongated neck and a precise calibration line, engineered to hold an exact known volume of liquid at a designated temperature.

28
New cards

Vernier Caliper

A precision mechanical tool featuring a fixed main scale and an aligned sliding scale used to measure external dimensions, internal dimensions, and depths.

29
New cards

Outside Jaws

The prominent lower jaws of a vernier caliper designed specifically for clamping and measuring external widths or outer diameters of objects.

30
New cards

Inside Jaws

The smaller upper jaws of a vernier caliper used to reach inside an object to measure internal diameters or hole widths.

31
New cards

Retainer (Setscrew)

A locking screw on a vernier caliper that fastens the movable sliding scale in place to allow easy reading and measurement transfer.

32
New cards

Density Replicate Agreement Criterion

The experimental quality benchmark requiring trial densities of an unknown substance to agree within 1%1\% to calculate an average; otherwise, a third trial is mandated.