Edit · NUR 209 Oxygen Therapy: Delivery Devices, Safety & Monitoring

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/22

encourage image

There's no tags or description

Looks like no tags are added yet.

23 Terms

1
New cards

What is required for supplemental oxygen to be administered?

It must be ordered or prescribed by a healthcare provider.

2
New cards

What should nurses educate clients about regarding oxygen therapy?

The purpose of oxygen therapy and the equipment needed.

3
New cards

What is a critical safety precaution when using oxygen?

Prevent fires by avoiding smoking and keeping a safe distance from fire sources.

4
New cards

What is the recommended distance to keep from a source of fire when using oxygen?

At least 6 feet away.

5
New cards

What should not be used in the area where oxygen is present?

Petroleum-based products, such as Vaseline.

6
New cards

How is oxygen flow rate measured?

In liters per minute (L/min).

7
New cards

What does FiO2 stand for?

The fraction of inspired oxygen, indicating the concentration of oxygen in the gas mixture.

8
New cards

What is the FiO2 percentage of room air?

21%.

9
New cards

Why is humidification used with supplemental oxygen?

To prevent drying and dehydration of the respiratory mucous membranes.

10
New cards

When is humidification necessary for oxygen delivery?

For higher flow rates (greater than 35%) or for clients with tracheostomy or artificial airways.

11
New cards

What is the maximum flow rate for a nasal cannula?

6 L/min.

12
New cards

What is a key feature of a nonrebreather mask?

It delivers the highest concentration of oxygen and must have an inflated reservoir bag.

13
New cards

What is the oxygen flow rate for a nonrebreather mask?

10 to 15 L/min.

14
New cards

What is the purpose of a Venturi mask?

To deliver a precise concentration of oxygen using the Venturi effect.

15
New cards

What are the two types of positive airway pressure devices mentioned?

Continuous positive airway pressure (CPAP) and bilevel positive airway pressure (BiPAP).

16
New cards

What should be monitored in clients receiving supplemental oxygen therapy?

Oxygen flow rate, respiratory rate, signs of cyanosis, and client comfort.

17
New cards

What is the goal for maintaining SpO2 in clients receiving oxygen therapy?

To use minimal oxygen while keeping SpO2 within the target range.

18
New cards

What can happen if the oxygen flow rate is set too low with a simple face mask?

There is a risk of retaining carbon dioxide.

19
New cards

What should be avoided to prevent skin breakdown when using face masks?

Prolonged use without monitoring skin integrity.

20
New cards

What is a disadvantage of using nasal cannulas?

They can dislodge easily and may cause dryness to the nasal mucosa.

21
New cards

What is the importance of ongoing client assessment during oxygen therapy?

To ensure adequate oxygenation and monitor for complications.

22
New cards

What type of water should be used for humidification?

Only distilled or sterile water.

23
New cards

What is the purpose of titrating oxygen flow rate?

To maintain the client's pulse oximetry above 95%.