1/20
Comprehensive vocabulary flashcards covering laboratory procedures, data interpretations, mathematical equations, particle-level models, and chemical concepts across gas laws, scientific measurements, nanoparticle synthesis, spectrophotometry, and calorimetry.
Direct Proportionality of Pressure and Temperature
The thermodynamic relationship where gas pressure increases linearly with temperature in Kelvin under constant volume, caused by gas molecules gaining kinetic energy and velocity, resulting in more frequent and forceful collisions against container walls.
Absolute Zero (Experimental Determination)
The theoretical temperature at which gas pressure reaches 0kPa, calculated by extrapolating the linear regression equation y=0.26827323x+75.20432855 to solve for x when y=0, yielding −280.3∘C.
Inverse Proportionality of Pressure and Volume
The relationship where gas pressure decreases as volume increases at constant temperature because molecules maintain constant velocity but occupy more space, colliding less frequently with the container walls.
Apparatus Leak Test
A procedure performed before gas data collection where air is removed with a syringe to reduce pressure, the 2-way valve is closed, and the pressure is monitored for 30seconds to confirm it does not rise back toward atmospheric pressure.
Analytical Balance
A high-precision mass-measuring instrument providing readings to 0.1mg (0.0001g) precision, requiring draft chamber doors to be closed during taring and weighing to avoid disturbances from ambient air currents.
Top-Loading Balance
A standard laboratory balance that reports mass measurements to two decimal places (0.01g), commonly used for general weighing tasks where analytical precision is not required.
Electrical Conductivity
A property measured in microsiemens per centimeter (μS/cm) that indicates the concentration of dissolved ions in solution, measured at 0.8μS/cm for pure RO water and rising to 11368μS/cm for concentrated salt solutions.
Sodium Borohydride (NaBH4)
A reducing agent that donates electrons to silver ions (Ag+) to trigger nucleation and initiate the growth of silver nanoparticles.
Sodium Bromide (NaBr)
A capping reagent that binds to etched silver ions on the nanoparticle surface, restricting particle growth and causing nanoparticles to remain smaller as its concentration increases.
Maximum Absorbance Wavelength (λmax) in Nanoparticles
The wavelength at which a nanoparticle suspension exhibits its highest light absorbance, shifting toward shorter wavelengths (from 641.9nm to 443.8nm) as particle size decreases.

Silver Ions (Ag+) in Solution
A sub-microscopic state consisting of individually dispersed silver cations possessing positive charges (Ag+) interacting directly with surrounding water molecules.

Silver Nanoparticles in Water
A colloidal suspension containing discrete clusters of silver atoms of uniform nanometer dimensions dispersed among solvent water molecules.

Bulk Silver Metal in Water
A macroscopic piece of solid silver metal (Ag(s)) that remains continuous and localized rather than dissolving into ions or suspending as nanoparticles.
Copper(II) Carbonate (CuCO3)
The insoluble solid precipitate, written with phase label CuCO3(s), formed from the stoichiometric reaction between aqueous copper(II) sulfate and aqueous sodium carbonate.
Beer's Law Calibration Curve
A linear plot of absorbance versus concentration for standard solutions (such as CuSO4) defined by a regression line (y=13.375x−0.014217) used to determine unknown sample concentrations.
Beer's Law Deviation at High Concentration
A departure from linearity observed at elevated concentrations because closely packed solute particles exert electrostatic charge interactions on one another, perturbing light absorption properties.
Beer's Law Deviation at Low Concentration
Scattering and non-linear behavior in spectrophotometric data caused by minimal light absorption reaching the baseline electronic noise and lower detection limits of the instrument.
Static Application Security Testing (SAST)
A white-box analytical testing method that inspects software source code, bytecode, or binary code to detect vulnerabilities without executing the application.
Dynamic Application Security Testing (DAST)
A black-box testing methodology that evaluates running applications from an external attacker's perspective by observing application behavior during execution.
Calorimeter Constant
The quantity of heat required to raise the temperature of a calorimeter assembly; substituting an insulating Styrofoam cup with a metal cup increases this constant because metal absorbs and conducts more heat.
Standard Enthalpy of Reaction (ΔHrxn∘) for Mg+H2O
The theoretical thermodynamic enthalpy change under standard state conditions for the reaction Mg(s)+H2O(l)→MgO(s)+H2(g), defined as −315.9kJ/mol.