1/31
Looks like no tags are added yet.
What is titration? (Worksheet match B)
A reagent of known concentration reacts with the analyte. Use the volume at the endpoint and the reaction's mole ratio to calculate the amount of analyte.
What is UV-Vis? (Worksheet match C)
Ultraviolet-visible spectroscopy measures light absorbed when electrons move to higher energy states. Look for clues like chromophores, conjugation, and absorbance.
What is IR? (Worksheet match F)
Infrared spectroscopy measures light absorbed as bonds stretch or bend. It helps identify functional groups such as carbonyls and provides a molecular fingerprint.
What is AAS? (Worksheet match A)
Atomic absorption spectroscopy measures light absorbed by free atoms. A is the worksheet's intended match, although its clue describes flame emission.
What does flame emission measure?
Light given off by excited atoms as they return to lower energy states. Sodium's yellow flame is an example.
What is ES? (Worksheet match E)
Molecular emission spectroscopy. In fluorescence, a molecule absorbs light and then emits light, usually at a longer wavelength than the excitation wavelength.
Why is fluorescence emission usually at a longer wavelength?
The molecule loses some energy before emitting light. The emitted photon has lower energy, which corresponds to a longer wavelength.
What is NMR? (Worksheet match K)
Nuclear magnetic resonance spectroscopy uses a magnetic field and radiofrequency energy to distinguish nuclear environments. Chemical shifts and splitting help determine structure.
What is MS? (Worksheet match D)
Mass spectrometry ionizes compounds and measures their mass-to-charge ratios, written m/z. High-resolution MS can help infer elemental composition.
What is GC? (Worksheet match H)
Gas chromatography uses a carrier gas to separate compounds that can vaporize and remain stable at the operating temperature. The oven temperature is often increased during the run.
What is LC? (Worksheet match J)
Liquid chromatography pumps a liquid mobile phase through a column. Compounds elute at different times because they interact differently with the stationary phase.
What is TLC? (Worksheet match I)
Thin-layer chromatography separates compounds on a coated plate as solvent rises by capillary action. Each compound's affinity for the two phases affects how far its spot travels.
What is CE? (Worksheet match G)
Capillary electrophoresis uses an electric field to separate analytes by mobility, which depends on charge and effective size. It is useful for analyzing peptides.
Which method can quantify an impurity that has a similar chromophore and acidic group to the drug?
Use LC-UV if the column separates the compounds and the impurity absorbs enough UV light. Measure the impurity peak area and use a calibration curve prepared with a known impurity standard.
Why is direct UV-Vis difficult for a drug and impurity with similar chromophores?
Both compounds can absorb at the same wavelength, so their signals add and the impurity's contribution is hard to isolate.
Why is direct acid-base titration difficult when the drug and impurity are both acidic?
Both compounds can consume the titrant, so the total volume may reflect both acids.
When could LC-MS, GC, or CE help measure the impurity?
LC-MS can help if the impurity gives a distinguishable ion. GC can work if the compounds are sufficiently volatile and thermally stable. CE can work if they have different mobilities in the chosen buffer. Quantitation still requires suitable calibration.
Why can peak area percent differ from mass percent?
The detector can respond more strongly to one compound than another, even when both are present in the same amount.
What generally makes a compound elute later?
Stronger interaction with the stationary phase generally increases retention time.
What factors can change elution time?
Analyte properties, stationary-phase chemistry, mobile-phase composition and pH, flow rate, column length, and temperature.
What happens when you increase methanol in the reversed-phase LC example?
The mobile phase elutes the hydrophobic compounds more strongly, so their retention times decrease.
Why can changing mobile-phase pH change retention?
pH can change the analyte's ionization, which changes how it interacts with the mobile and stationary phases.
What happens to elution time when flow or GC oven temperature increases?
Higher flow generally shortens elapsed retention times. A higher GC oven temperature usually helps compounds elute sooner.
What do two well-resolved peaks look like?
They have distinct apices and a valley that comes close to the baseline. Resolution describes the separation between two peaks.
How do you calculate peak resolution using baseline widths?
Rₛ = 2 × (later retention time − earlier retention time) ÷ (sum of the two baseline widths).
What is the resolution for peaks at 3 and 5 min with baseline widths of 1.0 and 1.2 min?
Rₛ = 2 × (5 − 3) ÷ (1.0 + 1.2) ≈ 1.82.
What resolution suggests near-baseline separation?
About 1.5 is a common rule of thumb for similarly sized, reasonably symmetric peaks.
What is the Van Deemter equation?
H = A + B/u + Cu, where H is plate height and u is the mobile-phase linear velocity. A smaller H means higher column efficiency.
What does the A term represent?
Eddy diffusion. Molecules take different paths through a packed column and arrive at different times. The simple model treats A as constant.
What does the B/u term represent?
Longitudinal diffusion. Molecules spread forward and backward along the column. Slower flow gives them more time to spread, increasing B/u.
What does the Cu term represent?
Resistance to mass transfer. Moving between or within phases takes time. At higher flow, molecules moving with the mobile phase can get farther ahead, increasing broadening.
Why can an intermediate flow give the best column efficiency?
At low flow, longitudinal diffusion causes more broadening. At high flow, resistance to mass transfer causes more broadening. The best velocity in this model is where plate height H is lowest.