overall darkness of radiogrpahic is called
Density
when looking at a radiograph we have to evaluate
the amount of density
when evaluating density what to you have to look at
through out image ( look at the entire image)
within the areas of interest
background
desnity can also be define as
The amount of light transmitted through the image
what is the formula of Density
DU = log incident light
transmitted light
ex: DU = log 1
% of light
What if 30% of the incident light is transmitted through the film, what is the density? ( this is if you are using decimal)
DU = log 1
.30
answer: X = .5185 0r .52
What if 50% of the incident light is transmitted through the film, what is the density? ( this is when you are using %)
DU = log 100%
50%
X = .301029 or .3
what is the optimal density for Bone
1.0 density unit ( .8-1.2 acceptable range)
What is the optimal density for lung
.5 density units (.4 to .6 acceptable range)
What is the optimal density for abdomen
.6 density units
what are the two factors that affect Density
Controlling factors (primary)
inflencing facotrs(secondary)
what is the primary control factor in density
mA and time and they are part of photographic
In density the influencing factors control
kV
SID
Processing Tissue (atomic #)
film/screen system
grid
beam restriction
generator phase
filtration
in the controlling factor(primary) ma(milliampes) controls
quanity of radiation( how much energy or current will be applied to the filament to be boiled off and turn into photon)
in controlling Factors time is the
Duration of exposure
In controlling factors (primary) mAs determines
the amount of radiaiton over a period of time- regulate density
when looking at the radiograph at the image is slightly light and a little more density what would you do
have the increase 30% of mAs is needed to visibly change optical density
when you double the amount of mAs what will you have to do with density
have to double density ( in useful range of density)
when you have to half the mAs what will happen to density
density will also have to be in halves ( in the useful range of density)
what is the realtionship between kV and density
kV=factor Density= image quality
ex: kV increases (penetration increases) the Density with go up
these two are directly porportion
kV is the
penetration of the part
if kV increases the penetration what will happen with remnant ( scatter) radiation
it will increase the amount of scatter radiation on the image and also density increases
if you decrease kV what will happen
you will have less penetration, less amount of radiation that will reach the image receptor and density will go down
kV is not
the optimal choice to change density, you are changing the penetration, and also change the scale of contrast
what does kV effect
Contrast and Resolution
what is the 15% rule show
if you increase 15% in kV you would double the the density (same as doubling mAs)
if you decrease 15% in kV you will half the density ( also change the scale of contrast)
8% changes in kV is about equal to
30% change in mAs
what you change a radiograph image to 8% what will it produce
produce noticeable/ visible change in density
what does SID follow
the inverse square law
when distance increase without composation what did you change
change distance, less radiation will be received in the image receptor,density will decrease as a result.
less radiation reaches the film due to
absorption of radiation in air as it travels greater distance
In mAs compensation when SID increases
the quantity decreases
what do you have to do in order to maintain density when SID has changed
mAs must be changed to compensate for new distance
what is the formula of mAs compensation
mAs1 = D12
mAs 2 D22
a question you would see for COMPENSATION NOT ABOUT RELATIONSHIP
What new mAs is needed to maintain the same density at a new distance
chemical processing in film image density has a
direct relationship
if temperature in chemical processing increases (even less than 1 degree)
we are going to see the density off the increase due to temperature
the the temperature increases
the chemical activity of solution increases
what is the ph level for concentration in chemical processing
ph 10-12
the the concentration increases (greater concentration)
the chemistry is going to work faster on the film and make it darker making density go up
what is the immersion time for chemical processing
20-30 sec
Atomic density in tissue density what are you talking about
talks about what it is made out of
Atomic density of the bone is higher than
bone = much higher (much dense)
soft tissue= more air
More radiation is needed to create more
remnant radiation
As tissue density increases what happens to image desnity
Density decreases (without compensation)
Bone has the greater
absorption characteristic
what is the atomic density for air
1
what is the atomic density for fluid
4-6
what is the atomic number for soft tissue
5-7
what is the atomic number for muscle(organ)
8
what is the atomic densities for bone
12
as density increases what will happen with absorption and image density
more absorption will occur and less image density
film speed is the
sensitivity film to the radiographic exposure
as film speed increases the what happens to the sensitivity of the film
¨as film speed increases the sensitivity of the film to radiation exposure increases
what would you need for radiation for film/screen combination
less radiation is needed to produce a density as film speed increases
what is the normal common film screen
Film speed
50
100
200-slow but not the slowest provides significant amount more of detail
300
400-is the standard used to measure the sensitivity of film to radiation.
800
What is the relationship between film speed and density?
the film screen increases density also increases again without no compensation of change
in order to maintain density what do you ahev to do with film speed and ma
the film speed need to change and mAs must change accordingly
as film speed increases
mAs needs to decrease to maintain density
What type of relationship does mAs have with film density
direct proportion
the formula of film speed/mAs
mAs1 = FS2
mAs2 FS1
for screen speed, if it increases what will happen with the photon
more photon are converted to light photons,therfore less radaition is needed to produce a density as screen speed increases
in order to maintain the same density as screen speed increases what will mAs do
mAs will decrease
What type of relationship does mAs have with screen speed?
inverse
Film type and speed must match
screen type and speed
Conventional film with
¨calcium tungstate screens
Orthochromatic film
with rare earth screens
what is the purpose of a grid
Used to reduce scatter radiation from reaching image receptor
grids are important
for exposure of 70 keV
grid a thin waffer looking plate that has
Aluminum strips with spacing
any photon that is not following the direction of the regular beam what will happen
scattered photons will be absorbed in aluminum strips
Reducing the size of the field reduces the amount of radiation reaching image receptor
Beam restriction
what do the lead shutters do for the collimation
absorb radiation
what is the percentage of collimation for 14 ×17
100%
what is the percentage of collimation for 11× 14
70% ;need to 30 % mAs
what is the percentage of collimation for 10×12
40%, you will have to another 30% (so 60%)
what is the percentage of collimation for 8 ×10
10%; you would have to compensate another 30% ( 60+30=90%)
If you used 8 mAs with a 14 x 17 and now collimated down to a 10 x 12 field size, you would now need to use 12.8 mAs
would now need to use 12.8 mAs
reduces the number of soft photons from the primary beam
Filtration
what are the two types of generator phase (current type)
single phase (1 line current)
three phase(3 line of current)
more current is applied what happens to density
the more electron are boiled off
need more time to produce X amount of radiation
Single phase
need less time to produce the same amount of radiation
Three phase
anode heel effect does not have
a direct effect on quanitity and intensity over all or amount of density
annode heel effect create
Uneven density
cathode side has
more radiation
anode side has
less radiation
Discrepancy increases with
increased SID
increase field size
less collimation
what does pathology influences
the amount of density that you will see on radiographic image
what are the two classification of pathology
Additive
descructive
what does additive disease adds and what does it increase
tissue fluid , material to the body and increases attenuation and greater absorption`