1/37
Vocabulary and procedural standards flashcards covering all 23 skills tested in the NAC Exam Part A Skills Test.
Handwashing Friction Duration
Lathering all surfaces of wrists, hands, and fingers producing friction for at least 20seconds, keeping hands lower than the elbows and fingertips down.
Fingernail Cleaning Technique (Handwashing)
Rubbing fingertips against the palms of the opposite hand to clean beneath the fingernails.
Drying and Faucet Procedure (Handwashing)
Drying surfaces from fingertips to wrists with clean, dry paper towels, and using a clean, dry paper towel or knee/foot control to turn off the faucet without touching the inside of the sink.
Supine Position (Elastic Stocking)
The lying-down-in-bed position required of the client while a knee-high elastic stocking is applied.
Knee-High Elastic Stocking Placement
Turning stocking inside-out at least to the heel, placing it over toes, foot, and heel, and pulling up the leg to finish wrinkle-free with the heel over the heel and toe opening placed correctly over or under the toes.
Transfer Belt Positioning
Securing the transfer belt around the client's waist over clothing or gown before assisting them to stand.
Candidate Assist Stance (Transfer Belt)
Facing the client, grasping the transfer belt on both sides with an upward grasp, and maintaining stability of the client's legs by standing knee-to-knee or toe-to-toe.
Ambulation Distance (Transfer Belt)
Walking slightly behind and to one side of the client for a distance of 10feet while holding onto the belt.
Head of Bed Positioning for Bedpan Use
Lowering the head of the bed prior to placing and removing the bedpan, and raising the head of the bed after the client is positioned on the bedpan.
Sink Preparation (Denture Cleaning)
Lining the bottom of the sink and/or partially filling the sink with water before holding dentures over it.
Denture Water Temperature Standard
Using moderate temperature running water to rinse dentures before and after brushing, and placing them in a denture cup filled with moderate temperature water or solution.
Radial Pulse Location
Located by placing fingertips on the thumb side of the client's wrist.
Radial Pulse Measurement Criteria
Counting beats for one full minute and recording the rate within ±4beats of the evaluator's reading.
Respirations Measurement Criteria
Counting respirations for one full minute and recording the rate within ±2breaths of the evaluator's reading.
PPE Donning Sequence
Unfolding gown, placing arms through sleeves, fastening neck opening, securing waist to cover back clothing, and putting on gloves so glove cuffs overlap gown cuffs.
Glove Removal Technique (PPE)
Grasping the palm of one gloved hand to peel it off, then slipping bare fingers under the cuff of the remaining glove to turn it inside out as it is removed.
Gown Removal Technique (PPE)
Unfastening waist and neck after gloves are removed, holding gown away from body without touching the floor or outside surface, and turning it inward to stay inside out.
Undressing Sequence (Affected Arm)
Removing the gown from the client's left (unaffected) side first, and then removing it from the right (affected/weak) side.
Dressing Sequence (Affected Arm)
Assisting the client to put their right (affected/weak) arm through the right sleeve of the shirt before placing the garment on the left (unaffected) arm.
Upright Sitting Position (Feeding)
Positioning the client at an angle of 75–90∘ prior to feeding and leaving them in this position after the meal.
Feeding Technique (Assisted Feeding)
Sitting facing the client, offering one bite of each type of food using a spoon, describing each spoonful's contents, and offering a beverage at least once during the meal.
Eye Cleansing Technique (Bed Bath)
Washing eyes with a wet washcloth without soap, utilizing a different area of the washcloth for each stroke from inner aspect to outer aspect.
Urinary Output Measurement Procedure
Pouring urine into a measuring container without splashing, reading amount at eye level on a flat surface, and rounding up to the nearest 25ml/cc if between lines.
Urinary Output Recording Margin
Recording container contents within ±25ml/cc of the evaluator's reading.
Scale Zeroing (Weight Measurement)
Setting the scale to zero before the client steps onto the center of the scale with non-skid shoes/footwear.
Ambulatory Weight Recording Margin
Recording weight within ±2lbs of the evaluator's reading, or within ±0.9kg if recorded in kilograms.
PROM Knee and Ankle Repetitions
Performing flexion/extension of the knee and dorsiflexion/plantar flexion of the foot at least 3times each, moving gently and stopping if the client verbalizes pain.
PROM Shoulder Movements
Supporting arm at elbow and wrist to raise arm upward to ear level (flexion/extension) and away from body to shoulder level (abduction/adduction) at least 3times each.
Side-Lying Supportive Device Placement
Placing supportive devices/pillows under head, supporting the top arm, behind the back, and between the legs with top knee flexed to keep knee and ankle supported.
Catheter Cleansing Distance and Motion
Holding catheter at meatus without tugging and cleaning, rinsing, and drying at least 4inches away from meatus in one direction with a clean cloth area per stroke.
Catheter Care Exposure Limit
Only exposing the client between the hip and knee while placing a linen protector under the perineal area and buttocks.
Foot Care Lotion Rule
Applying lotion to the top and bottom of the foot while strictly excluding the area between the toes, then wiping away excess lotion with a towel/washcloth.
Mouth Care Scope
Cleaning all surfaces of the client's teeth and the tongue using gentle motions with a moistened toothbrush and toothpaste while client sits at 75–90∘.
Female Perineal Cleaning Direction
Washing, rinsing, and drying both genital and rectal areas moving strictly from front to back, using a clean area of the washcloth for each stroke.
Wheelchair Alignment for Transfer
Positioning the wheelchair alongside the bed, situated at head of bed facing foot or foot of bed facing head, with wheels locked.
Wheelchair Final Seated Position
Lowering the client into the wheelchair until their hips touch the back of the wheelchair, removing the transfer belt, and positioning feet on footrests.
Manual Blood Pressure Cuff Inflation Range
Inflating the cuff between 160mm Hg and 180mm Hg, or reinflating to no more than 200mm Hg if a beat is heard immediately upon deflation.
Blood Pressure Measurement Margin and Rounding
Rounding measurements UP to the nearest 2mm of mercury and recording both systolic and diastolic pressures within ±8mm of the evaluator's reading.