prof prac
Consulting Architect
Architect who is professionally and academically qualified with recognized expertise
RA 9266- Architecture Act
PD1096- National Building Code
BP 344- Accessibility Law
RA 9514- Fire Code
BP 220- Standards of Economic & Socialized Housing
PD957- Subdivision and Condominium Buyers Protective Decree
Maestro De Obras- During the spanish period they primarily responsible for supervising the construction of churches, bridges , and public buildings before the formal profession
Maestro de obras - practice as an architect
Felix roxas y arroyo of bindondo
Liceo de manila, 1900 - first private school to offer an academic title
LPA - League of Philippine Architects
APGA- Association of Philippine Government Architects
PIA- Philippine Institute of Architects
RA 386- covers the legal framework governing personal and family relationship, ownership and rights over property.
15 years - years from the completion of a building can an architect be held liable if the structure collapses
Article 1723- whoever is responsible for the damage of the structure (contractor or architect or engineer) is liable
10 years- prescription period for filing cases if a building collapses
PRC- Professional Regulation Commission
Ar. Conrad Onglao - PRC Commissioner
Ar. Robert Mirafuente - PRBOA Chairman
RA 544- Engineering Law
RA 9266- more responsive and comprehensive regulation for the registration, licensing and practice of architecture
Architect of record - reminds team that all architectural drawings, specifications, and related documents must bear his seal signature and PRC number before the submission of the building official
Consulting Architect - expertise
Architectural firm - sole proprietorship , partnership, corporation
Sole proprietorship - DTI
Corporation- SEC
Authorship- owner of architectural plans
Board- refers to Regulatory board of architecture
Continuing Professional Development- sustaining and progressive learning process that maintains knowledge
15 units for 3 year PRC renewal
SEC - Securities and Exchange Commission
3840 hours - diversified experience requirement
No renewal of CoR
2 years- renewal of CoR if revoked
Expiration of PRC ID- birthday, every 3 years
Ramp- 1.20m
Gradient - 1:12
Length of ramp- 6m
Width of parking slot- 4 meters
Walkway- 1.2m
Pol mounted parking signage- .6x.6
United nations blue- color of ISA
Toiled cubicle- 1.8x1.8
Height of door knobs- 900mm
Elevator distance from building entrance- 30m
Air space for factories - 12 cubic meters
School rooms- 3 cubic meters
Habitable rooms - 14 cubic meters
Socialized housing- 450k budget (no finishes)
Economic housing- 450k but not exceeding 1.7m(with finishes)
Min open market single attached- 96sqm
Min open market single detached- 120sqm
Min open market floor area- 42sqm
Min lot area of duplex- 80sqm
Min single detached- 72sqm
Rowhouse frontage- 4m
Min frontage of irregular lot- 6m
Enforced BP344- DPWH
Min exit door width- 0.71m
Ramp gradient- 1:12m
Min width of hallway- 1:20m
Occupant load for standing room- 0:28m
Min corridor- 1:2m
Men washroom- equilateral triangle
Women washroom- triangle
Stairs for crutches- slanted nosing
Min corridor for hospitals- 2.44m
Occupant load for laboratory shop- 4.60sqm
Turn grove- 90 degrees
500-999 occupants- 3 exits
1000+ occupants- 4 exits
Classroom occupant load- 1:80sqm
Dry nursery occupant load- 2.50sqm
Min dimension of PWD toilet- 1.80m
Wheelchair turning space- 1.50m
Elevator to lobby- 30m
Issuance of permits- 15 days from payment
Min width of planting strip RROW 15m- 1.3m