Electrical
Q: What is the required clearance for service drops over walkways, patios, or the ground?
A: 10 feet.
Q: How high must service drops be above swimming pools?
A: 22 ½ feet.
Term: Drip loop for overhead triplex.
Definition: A loop in service wires to prevent water from entering the service head.
Q: What wire gauge is used for a 200-amp copper service entrance?
A: 2/0 AWG.
Q: What is a critical inspection step for sub-panels?
A: Ensure there are 4 wires and grounds and neutrals are not connected.
Q: Where are GFCIs required?
A: Bathrooms, kitchens, garages, outdoors, and unfinished basements.
Term: Federal Pacific Electric (FPE) “Stab-lok” breakers.
Definition: Known for safety issues and usually identified by red writing on the breaker tab.
Roofing
Q: What materials are used for roofs with less than a 2:12 slope?
A: Membrane or built-up type materials.
Term: Cedar shakes.
Definition: Requires a minimum slope of 4:12.
Q: What is a safety precaution for specialty roofs?
A: Do not walk on wood, metal, slate, cedar, clay, or other specialty roofs.
Q: What should be inspected around roof flashing?
A: Ensure flashing is properly sealed and free of corrosion.
Exterior
Q: What is the maximum opening for a perimeter railing?
A: 4 inches.
Q: How high should perimeter railings be for decks higher than 30 inches?
A: At least 36 inches.
Term: Weep holes.
Definition: Should be spaced 32 inches apart for brick veneer siding.
Q: What is the minimum height for siding above the ground?
A: 6 inches.
Interior
Q: What is the maximum height of a garage electric eye?
A: No more than 4 inches.
Q: What are the requirements for stair riser height and difference?
A: Risers should be 7” to 8”, with less than a 3/8” difference.
Term: Safety glass requirements.
Definition: Required within 24 inches of doors, 60 inches above floors, and near tubs or showers.
Q: What is the minimum tread depth for stairs?
A: 9 inches.
Plumbing
Q: What is the required drain size for a kitchen sink?
A: 1 ½ inches.
Term: Polybutylene (PB) piping.
Definition: A type of grey piping known for its high failure rate.
Q: What is the minimum clearance for plumbing vents from operable windows?
A: 10 feet away and at least 2 feet above.
Q: What is the maximum length for a straight dryer vent pipe?
A: 35 feet, subtracting 5 feet for each 90-degree elbow.
Q: What safety feature must be installed with water heaters in garages?
A: A bollard to protect against vehicle damage.
Q: What are venting requirements for water heaters?
A: Vents must terminate at least 1 foot above the roof and 10 feet away from operable windows.
Term: Dielectric union.
Definition: A fitting used to connect different metal pipes, preventing corrosion but also breaking the electrical ground.
Q: Why is material compatibility important in plumbing?
A: To prevent galvanic corrosion when connecting dissimilar metals (e.g., copper to galvanized steel).
Q: What is the minimum height for water heater relief valves?
A: Relief valves must be piped down to within 6 inches of the floor to prevent injury from hot water discharge.
Q: What is the required drain size for a kitchen sink?
A: 1 ½ inches.
Term: Polybutylene (PB) piping.
Definition: A type of grey piping known for its high failure rate.
Q: What is the minimum clearance for plumbing vents from operable windows?
A: 10 feet away and at least 2 feet above.
Q: What is the maximum length for a straight dryer vent pipe?
A: 35 feet, subtracting 5 feet for each 90-degree elbow.
Q: What safety feature must be installed with water heaters in garages?
A: A bollard to protect against vehicle damage.
HVAC/Heat Pump
Q: What is the minimum clearance required on the side of a condenser?
A: 12 inches.
Q: What is the normal operating pressure for a steam boiler?
A: 1/2 to 2 psi.
Term: Tridicator.
Definition: A gauge showing pressure and temperature, often found on circulated boilers.
Q: What is the operating temperature range for circulated boilers?
A: 140°F to 160°F.
Q: What is the recommended insulation for suction lines?
A: They should be insulated to prevent condensation and maintain efficiency.
Q: What should be checked during thermostat inspections?
A: Ensure proper wiring connections, secure mounting, and accurate temperature calibration.
Q: What should be inspected in ductwork?
A: Look for leaks, proper insulation, and cleanliness to maintain airflow and energy efficiency.
Q: What are tips for improving HVAC energy efficiency?
A: Regularly replace filters, seal duct leaks, and use programmable thermostats.
Q: What is the minimum clearance required on the side of a condenser?
A: 12 inches.
Q: What is the normal operating pressure for a steam boiler?
A: 1/2 to 2 psi.
Term: Tridicator.
Definition: A gauge showing pressure and temperature, often found on circulated boilers.
Q: What is the operating temperature range for circulated boilers?
A: 140°F to 160°F.
Q: What is the recommended insulation for suction lines?
A: They should be insulated to prevent condensation and maintain efficiency.
Safety
Q: What are the fireplace clearance requirements for combustible materials?
A: 6 inches for materials up to 1.5 inches thick; 12 inches for materials over 1.5 inches thick.
Term: Hearth depth.
Definition: Less than 6 ft² requires 16” depth and 8” on the sides; greater than 6 ft² requires 20” depth and 12” on the sides.
Q: Can different fuel types be mixed in the same chimney?
A: No, only the same fuels can be mixed.
Q: Where should smoke detectors be installed?
A: Inside and outside each bedroom and on every level of the home.
Q: Where should carbon monoxide detectors be installed?
A: Outside sleeping areas and on every level of the home.
Q: What should you check during general household safety inspections?
A: Ensure proper installation of smoke and CO detectors, inspect for tripping hazards, and verify that escape routes are clear.
Term: Carbon monoxide detector.
Definition: A device that alerts occupants to the presence of harmful CO gas, which is odorless and potentially lethal.
Q: What are the fireplace clearance requirements for combustible materials?
A: 6 inches for materials up to 1.5 inches thick; 12 inches for materials over 1.5 inches thick.
Term: Hearth depth.
Definition: Less than 6 ft² requires 16” depth and 8” on the sides; greater than 6 ft² requires 20” depth and 12” on the sides.
Q: Can different fuel types be mixed in the same chimney?
A: No, only the same fuels can be mixed.
Q: Where should smoke detectors be installed?
A: Inside and outside each bedroom and on every level of the home.