Engineer practical ques.
1. The minimum blowdown for a spring loaded safety valve shall be of what percent of the set pressure?
ANS: 10%
2. How is the Main Steam pressure gages tested?
ANS: With an Inspectors Gage
3. Who is in charge of the code for any plumbing installations?
ANS: The NYC Plumbing Code
4. When will anchorage or guides be inspected?
ANS: Annually
5. How many brass washout plugs does a miniature boiler have?
ANS: 3 Brass Washout Plugs 1” in size
6. How often is Hp piping expansion joints inspected?
ANS: Weekly
7. How long should a Hydronic System be pressure tested for?
ANS: 2 hours at no less than 100 PSIG
8. How is a gage protected from excessive pressure?
ANS: Shut off Cock
9. Who is authorized to witnessing a test on a gas piping system?
ANS: Plumbing Inspector, Architect, Licensed PE, Master Plumber, or Agency by the D.O.B
10. How should a remote disconnect be labeled?
ANS: Remote control for burner
11. When is a fusible plug not needed to be installed on a boiler?
ANS: Over 200 Psig
12. When shall a power boiler with a MAWP over 400 be tested?
ANS: Pressure tested annually
13. What shall a Design plan of a boiler and application contains but not limited to?
ANS: Size, Location, Operating Pressure + Temperature of the Pressure vessel, and Type + Specification of the PRV
14. Who is responsible for maintaining the copies of the certified welder qualifications report?
ANS: The Welding Agency and shall be available to the D.O.B
15. Who needs to furnish a control diagram and boiler operation instructions?
ANS: The Installer
16. Who will certify and calibrate all gages utilized for testing?
ANS: A Testing Operator
17. What shall be placed in between different joints and piping material?
ANS: An approved Adapter Fitting
18. What items are exempt from the reporting requirements?
ANS: The Seal Welds of Tubes and the Installation of Back Rings to Man holes and Hand Holes to Boilers
19. Who will be under control for any welding done to a High pressure tank?
ANS: an Engineer Supervising a welding inspection agency acceptable to the D.O.B
20. At what pressure is it required to have extra heavy valves installed?
ANS: 100 PSIG
21. The ___________ files an application for a boiler alteration
ANS: Inspector
22. How many safety valves does a boiler have with over 500 square feet of heating surface?
ANS: 2
23. Gas fired Boilers not exceeding 100 square feet of heating surface shall be provided with a?
ANS: Single or Double Cone type of Hood Diverter in the stack
24. A heater for either liquid fuels or other liquids harmful to the boiler shall not be installed?
ANS: Directly in the steam or water space within a boiler
25. Who is responsible for any spatial relationship between tanks and gas services?
ANS: The Installer of the last installation to correct the violation
26. Who is responsible for the setting of operating and safety controls?
ANS: The Installing Company
27. With what safety fitting shall you protect High Pressure Steam and water boilers with?
ANS: Dual Low Water Cut Outs**
28. Spring loaded safety valves have a total combined relieve capacity of?
ANS: 100% of the Max Designed Capacity of the Boiler
29. What is the total combined relieving capacity of power actuated relieving valves?
ANS: No less than 10% of the MAWP or no higher than 20% above the MAWP
30. What is the minimum blowdown for a spring loaded safety valve?
ANS: 2%
31. When a boiler is derated what changes?
ANS: The MAWP Decreases and the BTU Output
32. In Hydronic piping systems where shall a shutoff valve be installed?
ANS: Before and After the Pressure Reducing Valve
33. Hydronic piping joints between steel tubing and fittings shall be?
ANS: Mechanical or Welded
34. What appears on the plate of a boiler?
ANS: Serial #, Name of Manufacturer, Serial # of manufacturer, MAWP, Heating Surface, Year Built, and Rated Steam Capacity
35. Waste Gas removal of a boiler shall conduct the products of combustion where?
ANS: to the atmosphere
36. When a quick closing valve creates what hammer what is installed on the line?
ANS: A Water Hammer Adapter is installed
37. Safety valve capacity may be checked in what 3 ways?
ANS: Accumulation Test, Amount of Fuel Burned, Evaporative Capacity of Feed water
38. Records of inspects are kept where?
ANS: On the Premises
39. No joint anchorages or guides shall be repaired replaced or relocated without a work permit issued by the dept. this shall not apply to the repacking of a __________ or __________ joint.
ANS: Ball or Slip Joints
40. Internal high pressure inspection requires the boiler to be __________,__________, ___________ and _________.
ANS: Shutdown, Drained, Removal of Hand and Man Holes
41. The outlet of the blowoff tank is what size?
ANS: 2 times the diameter of the Blowdown piping, 6 inches internal entering the bottom of in the blow off tank
42. What info is not necessary to send to D.O.B?
ANS: Use, Type, Size, Location, Operating Temp of Pressure Tanks, and Location, Type, Specs of Pres Reliev. Valve
43. Miniature boiler specs are _____ I.D ____ ft gross volume ____ ft water heating surface ___ MAWP
ANS: 16 Inner Diameter, 5 Ft Gross Volume, 20 ft of heating surface, less than 100 PSIG
44. Safety valve popping tolerance + capacity up to 70 psig? 71-300 Psig? 301-1000 psig? >1000psig?
ANS: 70 psig = 2PSIG71-300PSIG = 3%301-1000PSIG = 10PSIG 1000PSIG+ = 1%
45. What are other ways of testing safety or relief valve for rated capacity?
ANS: Accumulation test, Amount of Fuel Burned, Evaporatative Capacity of Feed water
46. What is someone is found not following the rules and regulation for gas piping inspections?
ANS: Revocation of License
47. What range of the gage shall not excess when using a magnitude of 5 psig?
ANS: 10 psig (2x the Operating Pressure)
48. What can be connected to the float chamber or water column?
ANS: A Damper Regulator, a Feed water Regulator, a Gage, a Drain
49. On a steam gage what keeps the tube filled with water?
ANS: A Siphon
50. The minimum working clearance around boilers is ________? Vertical______?
ANS: The NYC code says 18”, while the High Pressure code says 24” | both Vertical 7ft
51. Boilers shall have all controls set, adjusted, and tested by
ANS: By the installer
52. Mufflers prevent ______
ANS: Back Pressure
53. External piping of a desuperheater in relation to a boiler has a _____ valve
ANS: Stop Valve (EXTERNAL)
54. When shall a boiler with a MAWP up to 400 psi be tested?
ANS: Once a year
55. What is the minimum safety or relief valve capacity for electric boilers?
ANS: 3 ½ lb/hr/kW
56. After welded repairs or alterations of the equipment, what shall retain a copy of the report?
ANS: The Owner
57. Any boiler changing location within the state may be reinstalled; an application for permission to install a second boiler is filled with whom?
ANS: Commissioner
58. When it is necessary to go on top of boilers for maintenance how much clearance is needed?
ANS: 7 Feet
59. Wet bottoms boiler shall be set above the floor not less than?
ANS: 12”
60. How do you set the pressure of the safety and relief valves? Find the _____?
ANS: Find the Nameplate of the Safety Valve
61. If there is one safety valve on an electric boiler what is the max output?
ANS: less than 1100 kw
62. What pressure shall a system using utility street steam have?
ANS: 200 PSIG at 413*F which than is reduced by a PRV
63. What chemical should be used for oxygen scavenging?
ANS: Sodium Sulfite or Sodium Hydroxide
64. What is the minimum distance from the wall to the Boiler?
ANS: 18” in NYC Construction Code, 24” in High Pressure Code
65. What is the lowest part of a water gage?
ANS: 2” above the lowest permissible water level
66. What standard are used on gages?
ANS: ASME, ANSI
67. What is the only thing that could tap onto a low water cut-off?
ANS: A Drain
68. How many expansion tanks are needed for 6 boilers?
ANS: 1
69. Who shall design the boiler system?
ANS: The Professional Engineer or the Architect
70. Gage to be measured in the magnitude of 5 psig shall not be calibrated in no less than?
ANS: 1/5” increments
71. At what percent do you hydrostatically test a boiler?
ANS: 150%
72. Beside a log book being inspected by a state boiler inspector who else can look at the book?
ANS: The Insurance Company
73. What is the difference between low pressure and high pressure safety relief valves?
ANS: Low Pressure relieves to a drain, while High pressure relieves to a vent
74. What is the minimum dial arc on a 2 ¼ gage?
ANS: 270*
75. Where is the steam gage installed on a mini boiler?
ANS: On the steam space side
76. What is an effective stop for a gauge?
ANS: The indicating point at zero
77. How long is the prepurge on a low pressure boiler?
ANS: 90 seconds
78. What does the Stamp (S) mean and the Stamp (h) mean?
ANS: S Means Power Boiler H Means Low Pressure Boiler
79. Each superheater shall be equipped with how many drains?
ANS: AT LEAST one
80. How often does an insurance inspector inspect the boilers?
ANS: Annually
81. What is the work that is done to a boiler that doesn’t have to be reported and is exempt?
ANS: Replacement of Backings to Man Holes and Hand Holes and Seal Welds to tubes
82. How do you prepare a brazed joint? A weld?
ANS: Braze: Clean, Flux, Heat, Filler Metal Weld: Clean, Convex, Weld a Filler Metal, Wire Wheel
83. Mufflers are not to be installed on___?
ANS: High Pressure Boilers
84. What would happen if your strainers from your discharge and supply lines are clogged?
ANS: Deep Vacuum
85. How many safety valves are on a miniature boiler?
ANS: 1 since only 20 sq ft
86. When connecting two different types of metallic pipe what is used in between?
ANS: A dielectric Kit or fitting
87. Where do you install gas service or distribution line from a new high pressure tank?
ANS: In a Separate Room
88. How many square feet of heating surface does a fusible plug require?
ANS: 50 sq ft
89. Where does a low pressure safety and relief valve discharge to?
ANS: The Drain
90. Electric boilers have two or more safety valves @ a power output of ___KW
ANS: 1100 KW
91. If an electric boiler is operating at a max of 1100 kW how many safety valves are required?
ANS: 2
92. When is a bullseye water sigh glass acceptable on a miniature boiler?
ANS: When there is insufficient space for a Gage Glass on a Mini Boiler
93. After an inspector notice is given to the owner where is it posted?
ANS: On or Close to the boiler
94. What type of welding shall the pipes of 2” or more have?
ANS: Butt Welding
95. Gage measured in the magnitude of 3 psig calibrated in increments of?
ANS: 1/10
96. What are the minimum and the maximum temp when performing a hydrostatic test?
ANS: Above Ambient Temperature CODE: 70-120*F
97. Where does a low pressure safety and relief valve discharge to?
ANS: A drain
98. How do you prepare a soldered joint?
ANS: Clean, Flux, Heat, Solder
99. How often do you bottom blow off?
ANS: Daily
100. Who authorizes changes to High Pressure piping anchors, guides and expansion joints without effect to health and safety?
ANS: the professional Engineer
101. When installing an expansion tank what factor is taken into consideration?
ANS: the MAWP of the Boiler System
102. If you are reading 12% Co2 what does it pertain to?
ANS: Incomplete Combustion
103. When should you inspect expansion joints?
ANS: Weekly
104. How far does a pressure tank to be away from any gas services?
ANS: 5 feet horizontal
105. Where is a remote disconnect located? What is it labeled?
ANS: Remote control for burner, located at the egress
106. What range of gage magnitude of 3 psig shall not exceed?
ANS: 1/10 increments @ 4.5PSIG (1 ½ x times) (they might say 5) to 6PSIG (2x times)
107. What is the minimum face size of a non mercury gage?
ANS: 2 ¼”
108. How many complete turns do a slow opening valve take from full-close to fill-open?
ANS: 5 360* Turns
109. What is the size pipe of the surface blow off?
ANS: 2 ½” Max
110. What is the pipe size of a gage cock connection?
ANS: ½”
111. How many gauge cocks are needed if a boiler is not over 36 inches in diameter and does not exceed 100 sq feet of heating surface?
ANS: 2
112. How do you protect a bottom blow off pipe when exposed to direct furnace heat?
ANS: Fire Brick
113. Who has prior approval by the D.O.B when an eminent health or safety hazard happens?
ANS: the professional Engineer
114. If a muffler is installed on a safety valve or safety relief valve the function is to?
ANS: Prevent Back pressure on a boiler
115. What do you do when adding a new tube to a boiler? Water tube boiler? Fire tube boiler?
ANS: Roll and ExpandWater Tube Roll and FlareFire tubeRoll and Bead
116. Prior to the Clean Air act what were boiler operations concerned with?
ANS: Sulfur Dioxide
117. What standard is plastic pipe/pvc in Hydronic systems held to?
ANS: ASTM
118. What boiler should be used for hot water?
ANS: A Low Pressure Hot Water Boiler operating at a max of 120 *F
119. What is potable water?
ANS: Drinking Water
120. What is the flame index of Insulation?
ANS: 25 Flame Index
121. What is the flame spread index of smoke density?
ANS: 450 Smoke Index
122. What are the allowed tapings of a water column?
ANS: Feed Water Regulator, Damper Regulator, Drain, Steam Gage
123. What is the seat of a safety valve composed of?
ANS: High Pressure is stainless, low pressure is bronze/ stainless
124. What is the minimum reading of a digital gage?
ANS: 1/100 of a PSIG
125. Where do you find the maximum setting for the safety and relief valves?
ANS: the nameplate of the Safety and Pressure Relief Valve
126. How many water gage glasses are needed over 400 psig boilers?
ANS: 2
127. There must be _______ gage cocks within the visible length of the water glass?
ANS: 3 Visible
128. When will the LWCO trip?
ANS: A ¼” below the lowest permissible water level given by the company who installed the LWCO
129. What pressure do you hydrostatically test a 400 psi boiler?
ANS: 600 psi
130. A boiler operates at 300 psi, it is tested once ______________?
ANS: Once a month and pressure tested every year
131. When a safety valve is replaced what is different?
ANS: Shall be equal to the last valve installed
132. What pressure will a safety valve lift completely?
ANS: 3%
133. Safety Valves shall be set at?
ANS: The MAWP
134. What kind of valve is located between the boiler and a safety valve?
ANS: None
135. Where no mechanical feed is attached to a boiler what is the safety valve set pressure?
ANS: 6%
136. PEX conforms to
ANS: ASME
137. Where shall a pressure relief valve be installed on a Hydronic piping system that has been reduced in pressure?
ANS: on the low pressure Side of the System
138. What size is the overflow on an open type of expansion tank?
ANS: 1”
139. What size is the inspectors test gage connection
ANS: ¼”
140. Where is the test gage connected to?
ANS: Shall be connected to the Boiler
141. Brazed joints use a filler metal that conforms to AWS A_._?
ANS: AWS A 5.8
142. Pipe Insulation shall have a maximum flame spread of _____?
ANS: 25 Flame Spread Index
143. Where does the gaseous waste of boiler combustion go?
ANS: Should be equipped with means for conducting products of combustion outside to the atmosphere
144. You blow down the boiler every?
ANS: Daily
145. The boiler shall be equipped with automatic devices responsive to variations in _______
ANS: Steam Pressure
146. What are all the specs of a Non mercury gage of magnitude of 3 psig
ANS: Has a Min of a 2 ¼” Gage, Dial 270* arc, Minimum increments of 1/10 PSIG, shutoff cock, indicating point at zero and has a calibration screw
147. What are all the specs of a non mercury gage of magnitude of 5 psig
ANS: Has Min of 2 ¼” Gage Dial, 270* arc, Minimum increments of 1/5 of a psig, Shut off cock, indicating point at zero, and has a calibration screw
148. A boiler operates at 100 psig, how many fusible plugs are there?
ANS: 1 Fusible Plug (over 50 sq ft)
149. A boiler operating at 100 psi mawp, how are pipes joined together?
ANS: Flanged or Welded
150. If you were getting 16-90psig from an outside source, what shall the system be designed for?
ANS: 125 PSIG
151. Where is shutoff valves located on a PRV?
ANS: Before and After the Pressure Reducing Valve
152. Natural Gas has how many Btu’s?
ANS: 960 Btu’s
153. What kind of scrubber does an incinerator have?
ANS: Wet Scrubber (slurry)
154. __________ is the term used with a wet absorber nozzle in relation to anincinerator.
ANS: Slurry
155. What is the first step of a hydrostatic test?
ANS: Fill the boiler with water till you see it up out the boiler vent
156. The size of each connection to a water column? Boiler-> W.C | G.G| Cocks| Test Gage| Drain
ANS: Boiler=> 1” W.C => ½” GG => ½” Cocks => ¼ Test Gage => ¾” Drain
157. How often do you test for water treatment of boiler feed water?
ANS: Daily
158. How do you decrease back pressure on a condensing engine?
ANS: Have the exhaust (steam) flow right into the (surface) condenser
159. Where is the absorber pump located in between?
ANS: Outlet Damper and the Stack
160. What is the minimum size for a safety valve?
ANS: ¾”
161. What is the capacity of a relief valve for a low pressure boiler under 30psig? Over 30psig?
ANS: under 30 PSIG has a relieve capacity of 20% above and over 30% is 10% above
162. In a low pressure boiler the safety valve shall not rise _ psi above the MAWP?
ANS: 5 PSI above the MAWP
163. A combustion regulator prevents water from rising above ___ *F or a steam pressure of __ in relation to LPB.
ANS: 250*F or a steam pressure of 15PSIG
164. The minimum size of a bottom blow off valve is?
ANS: ¾”
165. Relief valves on LPB are rated up to ___*F
ANS: 275*F
166. What are the 3 different types of stress?
ANS: Compression, Shear, Tensile
167. A low Pressure Boiler needs inspection if it occupies more than __ Families?
ANS: 6
168. One sq ft of fresh air for every ______ btu’s of fuel burned, in relation to LPB Gas Fire Burners
ANS: 2,000,000 Btu’s
169. Hydrostatic Inspection must has __ days notice
ANS: 15 Days
170. The certificate of inspection is placed?
ANS: As close to the boiler as possible
171. A L.P How Water Boiler is considered low pressure below?
ANS: 160PSIG @ 250*F
172. What size are brass wash out plugs on a mini boiler?
ANS: 1”
173. When your roll and expand tubes how far should they extend?
ANS: Evenly ¼”, ½”, ¾”
174. What item is not exempt from reporting requirements of welds?
ANS: Cracks on the Boiler Shell
175. What is the valve order on a desuperheater? Boiler Proper->____->____->_____
ANS: Stop Valve => Pressure Regulating Valve => Block Valve
176. Who cannot oversee a gas piping inspection?
ANS: Insurance Company
177. Hydronic system runs at 150 psi, hydrostatic test at 225 psi, rated to run at 115 psi what pressure should it not exceed?
ANS: 150PSIG
178. How would you prevent damage to piping due to temp changes?
ANS: Expansion Bends
179. How do you protect potable feed water for a boiler?
ANS: Pressure Vacuum Breaker
180. Brass pipes cannot be joined by
ANS: Solder
181. In relation to Testing of High Pressure steam Piping Systems, where the changes in an existing system involves less that 30% of the piping in the system, the testing may be done in accordance with?
ANS: ASME – On Hydrostatic Tests
182. Where is a siphon located?
ANS: before the gauge
183. On boilers with water jacked boiler furnace mouth, protector valves are locked and sealed open shall be of what type?
ANS: Of the Straight – Way Type
184. Ground source heat pump loop systems should be pressure tested for minutes at _ psi
ANS: 30 Minutes at no less than 100 psig
185. Street steam PSI and TEMP is then reduced by a PRV to 90- 16 pounds which is Designed as a ___psig system
ANS: 125 PSIG Systems
186. Forced steam flow generator safety valve relieve ___ of the MAWP, they pop at no less than % of the mawp and no higher then % of the MAWP and shall have ___ “fail safe” to stop the flow of ____ and ___ to the boiler, these valves then reseat at no less than __%
ANS: 100% of the MAWP pop no less than 10% and no higher than20%, with 2 fail safes stopping the flow of fuel and feed water to the boiler, reseat no less than 10%
187. On a boiler proper, if a safety valve pops it must relieve all the pressure without allowing that pressure to rise more than __% above the highest pressurerated
ANS: 6%
188. Safety valves are a ______-____ type?
ANS: Pop-Spring Type
189. The Minimum lift ” and a safety valve blowdown is % of the set pressure and no greater than % and must reseat at _% of the pressure?
ANS: Min Lift is 1/16 of a inch, Min safety valve blow down is 2%, fully lifted at 3% and reseats at 96% of the pressure.
190. The popping point tolerance shall not exceed 70=? 71-300=? 301-1000=? 1000+
ANS: 70 = 2PSIG+/- 71-300= 3%+/- 301-1000= 10PSIG+/- 1000+PSIG= 1%+/-
191. All piping over 2” shall be ____ welded?
ANS: Butt Welded
192. All piping under 2” shall be ____ welded or_____?
ANS: Socket Welded or Flanged
193. How long do you hydrostatically test a hydronic system? At a pressure not less than?
ANS: 2 hours @ <100PSI
194. 1cfm for every _____ Btu’s in accordance with forced combustion air
ANS: 2400 Btu’s
195. Who witnesses gas piping inspections?
ANS: an authorized Plumbing Inspector, or Licensed P.E or Master Plumber, or Architect
196. Repairs to Safety Valves Must be performed by an organization in possession of a
ANS: National Board V.R (Valve Repair) Certificate
197. When you roll and expand tubes how far should they extend?
ANS: Evenly ¼”, ½”, ¾”
198. A fuel regulating governor is controlled by?
ANS: Steam Pressure
199. The lowest permissible water level in a miniature boiler is?
ANS: 1/3”
200. The minimum size of a feed water connection to a miniature boiler is?
ANS: ½”
201. All miniature boiler openings in the boiler shall be (construction) _____________ or ______ reinforcement? How many threads?
ANS: Mechanical Construction with a minimum 4 threads, or Welded
202. How many brass washout plugs are on a Miniature boiler with less than 12 “ ID of shell and Less than 10 sq ft of heating surface?
ANS: only 2, where one may be used as a blow down line
203. Where the brass washout plugs of miniature boilers shall be screwed into?
ANS: On the bottom part of the Miniature boiler
204. A miniature boiler has less than ___ MAWP
ANS: less than 100 MAWP (PSI)
205. A miniature boiler has up to __ sq ft of heating surface?
ANS: 20 Sq Ft of heating surface
206. A miniature boiler has up to___ cubic ft of gross volume?
ANS: 5 cubic ft of gross volume
207. A miniature boiler has up to__” of ID of shell?
ANS: 16” Inner Diameter
208. Any MOUTH PROTECTOR on a boiler shall be locked or sealed ____. What type?
ANS: Locked or Sealed Open, of the Straight Way Type
209. When are fusible plugs replaced?
ANS: Annually
210. When a discharge pipe is used on a safety valve it shall be ____ (size) of the safety valve, and fitted with a ___ drain?
ANS: no less than the same size, fitted with a open drain
211. Three different ways to check the safety valve capacity?
ANS: Accumulation Test, Maximum amount of fuel burned, Maximum evaporative capacity of feed water
212. If a boiler has a Lap Seal Crack it shall be?
ANS: Discontinued
213. What is stamped on a Boiler?
ANS: Serial #, Name of Manufacturer, Serial # of manufacturer, MAWP, Heating Surface, Year Built, and Rated Steam Capacity
214. What is stamped on a boiler identification plate?
ANS: NAME, ID#, CLASS, Tensile Strength (according to the High Pressure code)
215. Safety valves are ____ or held by a ___ during a hydrostatic test?
ANS: Removed or Approved Clamp
216. If a boiler is gravity fed, there shall be what valves on the line?
ANS: A stop valve as close as the boiler as possible followed by a Check valve
217. What must you not adjust on the safety valve during a hydrostatic test?
ANS: The compression screw
218. What is the max psig of a water column constructed of Cast iron? Malleable iron?
ANS: Cast Iron = 250 PSIG Malleable Iron = 350
219. What is the minimum size of the blow off piping?
ANS: 3/4
220. When shall a water column have a shield of a sleeve?
ANS: Over 400 PSIG
221. What is the minimum size of a feed water piping connection to a boiler with less than 100 sq ft of heating surface? More than 100 sq ft of heating surface?
ANS: The minimum Less than 100 sq ft is ½” and more than 100 sq ft is ¾”
222. When shall a boiler have at least two means of feed water?
ANS: When the boiler is over 500 SQ FT of Heating Surface
223. How many drains are on a super heater, and is the minimum size in inches?
ANS: 1 drain measuring a minimum of 1”
224. Boilers have 2 bottom blow downs when the MAWP exceeds___ psi?
ANS: 100 PSIG
225. What schedule pipe can you use on boiler blow down lines?
ANS: Schedule 80
226. What is the Maximum size of a blow down valve? Minimum size and less than how many sq feet?
ANS: 2 ½ ”, ¾” less than 100 sq ft
227. All boiler fittings are what standard?
ANS: ASME
228. How many gage cocks are on a boiler with less than 36 “and 100 sq ft of surface?
ANS: 2
229. How many gage cocks are on a boiler with over 36” and more than 100 sq ft of surface?
ANS: 3
230. What size are the gage cocks on a boiler?
ANS: ½”
231. How many gage cocks does a boiler have with two water glasses on the same horizontal line?
ANS: 2 Cocks @ ½”
232. Any valve used as a shutoff to a water column shall be sealed ___ and ____.
ANS: Sealed Open and LOCKED
233. HRT Fire tube boiler what is the minimum water level in a gage glass?
ANS: 3”
234. What can be attached to the same outlet from a super heater that is used also for the safety valve connection?
ANS: Soot Blower
235. A safety valve over 3” and over 15 psig shall have what type of inlet connection?
ANS: Flanged or Welded
236. The discharge of safety valves or safety relief valves shall be located so as to prevent ______
ANS: Scalding
237. Safety valve plate has what?
ANS: Name, Manufacturer #, Size, Seat, Pressure (PSIG), Year built, Capacity, Capacity lift, ASME
238. Where an isolation transformer is provided, one conductor of the secondary winding shall be?
ANS: Grounded
239. When would a heat exchanger not need shutoff valves?
ANS: When it is integral with the boiler
240. The flash point in a Hydronic system is __*F above the maximum operating temperature.
ANS: 50 *F
241. The slope of piping for condensate is __%
ANS: 1/%
242. Piping Supports (Mechanical code 2008)
a. Steel Pipe Supports are spaced every Ft horizontal and Ft vertical
ANS: 12 Ft Horizontal and 15 Ft Vertical
b. Steel tube Supports are spaced every Ft horizontal and Ft vertical
ANS: 8 Ft Horizontal and 10 Ft Vertical
243. What is the Inspection Frequency of a Boiler?
a. Low Pressure Steam Internal and External?
ANS: Internal every 3 years and External every 2 years
b. Low Pressure Hot Water Internal and External?
ANS: Internal every 5 years and External every 2 years
c. High Pressure Steam Internal and External?
ANS: Internal every 1 year and External every 1 year
d. High Pressure Hot Water Boilers?
ANS: Internal every 3 years and External every 1 year