DC Circuit Vocabulary

Fundamental Electrical Concepts

  • Electric Current:

    • Definition: Electric current is the rate of flow of free electrons through a conductor.
    • SI Unit: Ampere (A\text{A}).
    • Visual representation of charge flow in a conductor:         Electric Current Visual Representation
  • Electric Potential and Potential Difference:

    • Electric Potential: The amount of work done per unit charge in bringing a charge from infinity to a specific point in an electrostatic field against electrostatic forces.
    • Alternative Term: Voltage.
    • SI Unit: Volt (V\text{V}).
    • Property: Scalar quantity.
    • Formula:         Electric Potential=Work DoneUnit Charge\text{Electric Potential} = \frac{\text{Work Done}}{\text{Unit Charge}}
    • Potential Difference: The amount of work required to move a unit charge between two specific locations within an electric field.
  • Electric Power:

    • Definition: The rate at which electrical work is done or energy is transformed.
    • SI Unit: Watt (W\text{W}), equivalent to one Joule per second (1 W=1 J/s1\,\text{W} = 1\,\text{J/s}).
    • Mathematical Formula:         P=V×IP = V \times I
  • Ohm's Law:

    • Statement: The ratio of potential difference (VV) across any two points of a conductor to the current (II) flowing through it is constant, provided the temperature of the conductor remains unchanged.
    • Mathematical Formulation:         VI=constant=R\frac{V}{I} = \text{constant} = R
    • Standard Form:         V=I×RV = I \times R

Passive Circuit Elements

  • Resistance:

    • Definition: The opposition offered by a substance or material to the flow of electric current.
    • Physical Mechanism: When a potential difference is applied across a conductor, free electrons accelerate and collide with the fixed atoms and molecules of the conductor material. These collisions restrict the rate of flow of electrons, thereby resisting current flow.
    • SI Unit: Ohm (Ω\Omega).
    • Symbolic Notation: RR or rr
    • Schematic Symbol:         Resistor Symbol
    • Factors Affecting Resistance:
      • Length of Conductor (ll): Resistance is directly proportional to conductor length (R∝lR \propto l).
      • Cross-Sectional Area (aa): Resistance is inversely proportional to cross-sectional area (R∝1aR \propto \frac{1}{a}).
      • Temperature: Resistance generally increases as temperature rises and decreases as temperature falls.
    • General Mathematical Expression:         R=ρla ΩR = \rho \frac{l}{a}\,\Omega(where ρ\rho represents the resistivity of the material)
  • Inductance:

    • Definition: A property of an electrical component or coil that stores energy in a magnetic field and opposes any rapid or time-dependent change in current magnitude or direction passing through it.
    • Physical Mechanism: Current flowing through a coil generates a surrounding magnetic field. Any variation in current magnitude alters the magnetic flux, inducing an electromotive force (emf) across the coil.
    • Mathematical Formula:         V=LdIdt VV = L \frac{dI}{dt}\,\text{V}(where VV is voltage, LL is inductance, II is current, and tt is time)
    • SI Unit: Henry (H\text{H}), named in honor of American scientist Joseph Henry for discovering electromagnetic induction.
    • Inductor Symbol:         Inductor Symbol Diagram
  • Capacitance:

    • Definition: A two-terminal circuit property that enables charge storage, thereby storing electrical energy in the form of an electric field/voltage.
    • Mathematical Formula:         C=QV FC = \frac{Q}{V}\,\text{F}(where CC is capacitance in Farads, QQ is charge in Coulombs, and VV is potential difference in Volts)
    • Current-Voltage Relation:         I=CdVdt AI = C \frac{dV}{dt}\,\text{A}
    • Capacitor Symbol:         Capacitor Symbol Diagram

Classification of Electrical Sources

  • Hierarchical Taxonomy of Sources:     Sources Hierarchy Chart

    • Sources are divided into Voltage Sources and Current Sources.
    • Voltage Sources are sub-divided into Ideal Voltage Sources and Practical Voltage Sources.
    • Current Sources are sub-divided into Ideal Current Sources and Practical Current Sources.
  • Voltage Sources:

    • Definition: A passive model element capable of supplying continuous electromotive force to drive free electrons through a connected circuit path; typically configured as a two-terminal device.
    • Independent Voltage Source:
      • Delivers a constant or time-varying voltage that is completely independent of currents or voltages present elsewhere in the circuit.
      • Direct Voltage Source (Time Invariant Voltage Source): Produces a steady, time-invariant output voltage where polarity and electron flow direction remain constant over time. Examples include DC generators, chemical batteries, and cells.
      • Alternating Voltage Source: Delivers voltage that periodically alternates magnitude and direction over time.
    • Dependent Voltage Source:
      • Produces an output voltage whose magnitude is controlled by another voltage or current existing at a different location within the circuit network.
      • Subtypes: Voltage-Controlled Voltage Source (VCVS) and Current-Controlled Voltage Source (CCVS).

Network Terminology: Nodes, Branches, and Loops

  • Branch: Represents a single two-terminal circuit element within a network, such as a individual resistor, current source, or voltage source.
  • Node: A connection terminal or point where two or more circuit branches intersect.
  • Loop:
    • Definition: Any closed continuous conductive path formed by starting at a specific node, passing through a series of connected nodes, and returning to the original starting node without traversing any single node more than once.
    • Independent Loop: A closed loop that encompasses at least one branch that is not shared with any other existing independent loop. Independent loops generate linearly independent network equations.
    • Loop Set Example: In a multi-node circuit containing branches connected between nodes aa, bb, and cc, an independent loop set can consist of loop abcaabca containing a 2 Ω2\,\Omega resistor, a second loop containing a 3 Ω3\,\Omega resistor and current source, and a third loop containing parallel resistive branches.

Resistors in Series and Parallel

  • Resistors Connected in Series:

    • Circuit Characteristics: End-to-end connection of resistors such that a single common current II flows sequentially through every component.
    • Total Equivalent Resistance:         RT=R1+R2+R3+⋯+RnR_T = R_1 + R_2 + R_3 + \dots + R_n
    • Series Circuit Example:         Series Resistor Network Diagram
      • Parameters: Resistors R1=1 kΩR_1 = 1\,\text{k}\Omega, R2=2 kΩR_2 = 2\,\text{k}\Omega, R3=6 kΩR_3 = 6\,\text{k}\Omega in series with a 1 mA1\,\text{mA} current source.
      • Voltage across R1R_1: V1=I×R1=1 mA×1 kΩ=1 VV_1 = I \times R_1 = 1\,\text{mA} \times 1\,\text{k}\Omega = 1\,\text{V}
      • Voltage across R2R_2: V2=I×R2=1 mA×2 kΩ=2 VV_2 = I \times R_2 = 1\,\text{mA} \times 2\,\text{k}\Omega = 2\,\text{V}
      • Voltage across R3R_3: V3=I×R3=1 mA×6 kΩ=6 VV_3 = I \times R_3 = 1\,\text{mA} \times 6\,\text{k}\Omega = 6\,\text{V}
      • Total Applied Voltage: VT=1 V+2 V+6 V=9 VV_T = 1\,\text{V} + 2\,\text{V} + 6\,\text{V} = 9\,\text{V}
  • Resistors Connected in Parallel:

    • Circuit Characteristics: Components connected across common node pairs such that the full supply voltage VV is impressed across every individual branch.
    • Equivalent Resistance Formula:         1RT=1R1+1R2+1R3+⋯+1Rn\frac{1}{R_T} = \frac{1}{R_1} + \frac{1}{R_2} + \frac{1}{R_3} + \dots + \frac{1}{R_n}
    • Parallel Circuit Calculation Example:
      • Given Parallel Network: R1=200 ΩR_1 = 200\,\Omega, R2=470 ΩR_2 = 470\,\Omega, R3=220 ΩR_3 = 220\,\Omega
      • Reciprocal Sum Calculation:             1RT=1200+1470+1220=0.0050+0.002128+0.004545=0.0117 Ω−1\frac{1}{R_T} = \frac{1}{200} + \frac{1}{470} + \frac{1}{220} = 0.0050 + 0.002128 + 0.004545 = 0.0117\,\Omega^{-1}
      • Equivalent Resistance:             RT=10.0117=85.67 ΩR_T = \frac{1}{0.0117} = 85.67\,\Omega

Kirchhoff's Laws

  • Kirchhoff's Current Law (KCL):

    • Statement: The total electric charge or current entering a node/junction is precisely equal to the charge leaving that node, as charge cannot accumulate or be consumed within a junction.
    • Algebraic Expression:         Ientering+Iexiting=0I_{\text{entering}} + I_{\text{exiting}} = 0
    • Sign Convention: Currents directed into a node are designated as positive (+\), while currents directed away from a node are designated as negative (-\).
    • Nodal Equation:         KCL Node Diagram
      • For three entering currents (I1,I2,I3I_1, I_2, I_3) and two leaving currents (I4,I5I_4, I_5):             I1+I2+I3+(−I4)+(−I5)=0I_1 + I_2 + I_3 + (-I_4) + (-I_5) = 0I1+I2+I3−I4−I5=0I_1 + I_2 + I_3 - I_4 - I_5 = 0I1+I2+I3=I4+I5I_1 + I_2 + I_3 = I_4 + I_5
    • Primary Application: Analyzing parallel circuits and setting up nodal equations.
  • Kirchhoff's Voltage Law (KVL):

    • Statement: In any closed loop electrical network, the algebraic sum of all potential differences (voltage drops and electromotive forces) around the loop equals zero.
    • Algebraic Expression:         ∑V=0\sum V = 0
    • Loop Direction Rule: Traversal around a closed circuit loop must maintain a single direction (either clockwise or counter-clockwise) continuously across nodes A,B,C,DA, B, C, D:         KVL Loop DiagramVAB+VBC+VCD+VDA=0V_{AB} + V_{BC} + V_{CD} + V_{DA} = 0
    • Primary Application: Analyzing series circuits and establishing loop/mesh equations.
  • Comprehensive KVL & KCL Numerical Demonstration:

    • Circuit Parameters: Two DC sources (V1=10 VV_1 = 10\,\text{V}, V2=20 VV_2 = 20\,\text{V}) supplying three resistors (R1=10 ΩR_1 = 10\,\Omega, R2=20 ΩR_2 = 20\,\Omega, R3=40 ΩR_3 = 40\,\Omega) connected across nodes AA and BB.
    • KCL Nodal Equations:
      • Node AA: I1+I2=I3I_1 + I_2 = I_3
      • Node BB: I3=I1+I2I_3 = I_1 + I_2
    • KVL Loop Equations:
      • Loop 1: 10=R1I1+R3I3  ⟹  10=10I1+40I310 = R_1 I_1 + R_3 I_3 \implies 10 = 10 I_1 + 40 I_3
      • Loop 2: 20=R2I2+R3I3  ⟹  20=20I2+40I320 = R_2 I_2 + R_3 I_3 \implies 20 = 20 I_2 + 40 I_3
      • Loop 3 (Outer Loop): 10−20=10I1−20I2  ⟹  −10=10I1−20I210 - 20 = 10 I_1 - 20 I_2 \implies -10 = 10 I_1 - 20 I_2

Star-Delta and Delta-Star Transformations

  • Star to Delta (Y→Δ\text{Y} \rightarrow \Delta) Transformation:

    • Transformation Principle: Any individual resistance value in a Delta (Δ\Delta) network (A,B,CA, B, C) is equal to the sum of all pair-wise products of Star (Y\text{Y}) network resistors (P,Q,RP, Q, R) divided by the Star resistor located directly opposite to the target Delta resistor.
    • Transformation Schematic:         Star-Delta Transformation Diagram
    • Transformation Formulas:
      • Resistor AA (opposite to Star resistor RR):             A=PQ+QR+RPR=PQR+Q+PA = \frac{PQ + QR + RP}{R} = \frac{PQ}{R} + Q + P
      • Resistor BB (opposite to Star resistor QQ):             B=PQ+QR+RPQ=RPQ+P+RB = \frac{PQ + QR + RP}{Q} = \frac{RP}{Q} + P + R
      • Resistor CC (opposite to Star resistor PP):             C=PQ+QR+RPP=QRP+Q+RC = \frac{PQ + QR + RP}{P} = \frac{QR}{P} + Q + R
    • Worked Star to Delta Conversion Example:
      • Given Star Network Values: P=150 ΩP = 150\,\Omega, Q=180 ΩQ = 180\,\Omega, R=60 ΩR = 60\,\Omega
      • Calculating Delta Resistor AA:             A=180×15060+180+150=450+180+150=780 ΩA = \frac{180 \times 150}{60} + 180 + 150 = 450 + 180 + 150 = 780\,\Omega
      • Calculating Delta Resistor BB:             B=60×150180+60+150=50+60+150=260 ΩB = \frac{60 \times 150}{180} + 60 + 150 = 50 + 60 + 150 = 260\,\Omega
      • Calculating Delta Resistor CC:             C=180×60150+180+60=72+180+60=312 ΩC = \frac{180 \times 60}{150} + 180 + 60 = 72 + 180 + 60 = 312\,\Omega
  • Delta to Star (Δ→Y\Delta \rightarrow \text{Y}) Transformation:

    • Transformation Principle: Each Star resistor connected to a terminal terminal is equal to the product of the two adjacent Delta resistors intersecting at that terminal, divided by the sum of all three Delta network resistors (A+B+CA + B + C).
    • Transformation Schematic:         Delta-Star Transformation Diagram
    • Transformation Formulas:
      • Star Resistor PP (terminal 1):             P=ABA+B+CP = \frac{AB}{A + B + C}
      • Star Resistor QQ (terminal 2):             Q=ACA+B+CQ = \frac{AC}{A + B + C}
      • Star Resistor RR (terminal 3):             R=BCA+B+CR = \frac{BC}{A + B + C}
    • Algebraic Derivation Summary:
      • P=Eq1+(Eq3−Eq2)P = \text{Eq}_1 + (\text{Eq}_3 - \text{Eq}_2)
      • Q=Eq2+(Eq1−Eq3)Q = \text{Eq}_2 + (\text{Eq}_1 - \text{Eq}_3)
      • R=Eq3+(Eq2−Eq1)R = \text{Eq}_3 + (\text{Eq}_2 - \text{Eq}_1)
    • Worked Delta to Star Conversion Example:
      • Given Delta Network Values: A=20 ΩA = 20\,\Omega, B=30 ΩB = 30\,\Omega, C=80 ΩC = 80\,\Omega
      • Denominator Sum: A+B+C=20+30+80=130 ΩA + B + C = 20 + 30 + 80 = 130\,\Omega
      • Calculating Star Resistor QQ:             Q=20×80130=1600130=12.31 ΩQ = \frac{20 \times 80}{130} = \frac{1600}{130} = 12.31\,\Omega
      • Calculating Star Resistor PP:             P=20×30130=600130=4.61 ΩP = \frac{20 \times 30}{130} = \frac{600}{130} = 4.61\,\Omega
      • Calculating Star Resistor RR:             R=30×80130=2400130=18.46 ΩR = \frac{30 \times 80}{130} = \frac{2400}{130} = 18.46\,\Omega

Thevenin's Theorem

  • Theorem Statement:

    • Any linear active electrical network containing independent or dependent voltage and current sources together with linear passive elements can be replaced across any two specified output terminals by a simplified equivalent circuit consisting of a single voltage source (VTHV_{TH}) connected in series with an internal equivalent resistance (RTHR_{TH}).
    • VTHV_{TH} (Thevenin Voltage): The open-circuit voltage measured or calculated across the open load terminals.
    • RTHR_{TH} (Thevenin Resistance): The equivalent input resistance looking into the open load terminals with all independent energy sources deactivated.
  • Thevenin Equivalent Circuit Structure:     Thevenin Equivalent Circuit Diagram

  • Systematic Analysis Steps:

    1. Disconnect and remove the load resistor RLR_L from the target circuit terminals A−BA-B.
    2. Calculate the open-circuit terminal voltage VOCV_{OC}, which equals VTHV_{TH}.
    3. Deactivate all independent sources in the circuit network: replace ideal voltage sources with short circuits and ideal current sources with open circuits. Calculate the equivalent internal resistance RTHR_{TH} viewed from open terminals A-B$.\n 4. Construct the Thevenin equivalent circuit by connecting V_{TH}inserieswithin series withR_{TH}andreconnectingand reconnectingR_L.\n 5. Calculate the load response using Ohm's Law:\n       I_L = \frac{V_{TH}}{R_{TH} + R_L}\n       V_L = I_L \times R_L\n\n* Complete Numerical Step-by-Step Problem Solution:\n * Problem Circuit: A 48\,\text{V}DCvoltagesourcefeedinganetworkwithDC voltage source feeding a network withR_1 = 12\,\text{k}\Omega,,R_2 = 4\,\text{k}\Omega,,R_3 = 8\,\text{k}\Omega,andloadresistor, and load resistorR_L = 5\,\text{k}\Omegaconnectedacrossterminalsconnected across terminalsA-B$.
    • Step 1 (Disconnect Load): Remove RL=5 kΩR_L = 5\,\text{k}\Omega from terminals AA and B$.\n * Step 2 (Determine V_{TH}):\n * With terminals A-Bopen,nocurrentflowsthroughresistoropen, no current flows through resistorR_3 = 8\,\text{k}\Omega\n * Total loop resistance for the energized path: 12\,\text{k}\Omega + 4\,\text{k}\Omega = 16\,\text{k}\Omega\n * Loop current: I = \frac{48\,\text{V}}{16\,\text{k}\Omega} = 3\,\text{mA}\n * Voltage drop across 4\,\text{k}\Omegaresistor:resistor:V_{4k} = 3\,\text{mA} \times 4\,\text{k}\Omega = 12\,\text{V}\n * Since 8\,\text{k}\Omegacarrieszerocurrent,theentirecarries zero current, the entire12\,\text{V}appearsacrossterminalsappears across terminalsA-B:\n            V_{TH} = V_{AB} = 12\,\text{V}\n * Step 3 (Determine R_{TH}):\n * Short-circuit the 48\,\text{V} DC voltage source.\n * Looking back through terminals A-B,the, the8\,\text{k}\Omegaresistorisinserieswiththeparallelcombinationofresistor is in series with the parallel combination of12\,\text{k}\Omegaandand4\,\text{k}\Omega\n * Parallel combination calculation:\n            R_{\text{parallel}} = \frac{12\,\text{k}\Omega \times 4\,\text{k}\Omega}{12\,\text{k}\Omega + 4\,\text{k}\Omega} = \frac{48}{16} = 3\,\text{k}\Omega\n * Total Thevenin resistance:\n            R_{TH} = 8\,\text{k}\Omega + 3\,\text{k}\Omega = 11\,\text{k}\Omega\n * Step 4 (Calculate Load Response):\n * Connect V_{TH} = 12\,\text{V}inserieswithin series withR_{TH} = 11\,\text{k}\OmegaandandR_L = 5\,\text{k}\Omega\n * Load current:\n            I_L = \frac{12\,\text{V}}{11\,\text{k}\Omega + 5\,\text{k}\Omega} = \frac{12\,\text{V}}{16\,\text{k}\Omega} = 0.75\,\text{mA}\n * Load voltage:\n            V_L = I_L \times R_L = 0.75\,\text{mA} \times 5\,\text{k}\Omega = 3.75\,\text{V}\n\n# Norton's Theorem\n\n* Theorem Statement:\n * Any linear active electrical network consisting of independent or dependent voltage and current sources together with linear passive elements can be substituted across its output terminals by an equivalent circuit containing a constant current source (I_NororI_{SC})inparallelwithaninternalresistance() in parallel with an internal resistance (R_NororR_{int}).\n * Dual Relationship: Norton's theorem is the converse/dual representation of Thevenin's theorem.\n * I_{SC} (Short-Circuit Current): The current flowing through the load terminals when shorted together.\n * R_N(NortonResistance):Equivalentinternalresistanceviewedfromtheopenloadterminals,identicalinmagnitudeto(Norton Resistance): Equivalent internal resistance viewed from the open load terminals, identical in magnitude toR_{TH}.\n\n* Norton Equivalent Circuit Structure:\n    ![Norton Equivalent Circuit Diagram](https://assets.knowt.com/pdf-flow-prod/97b6ae74-cdd3-4906-924e-95dc1681d3c4-figures/47.jpg)\n\n* Systematic Analysis Steps:\n 1. Remove the load resistor R_Lfromterminalsfrom terminalsA-B and replace it with a short circuit.\n 2. Calculate short-circuit current I_{SC}passingthroughshortedterminalspassing through shorted terminalsA-Busingstandardcircuitanalysis;thisdefinesusing standard circuit analysis; this definesI_N.\n 3. Deactivate all independent sources (short voltage sources, open current sources) and evaluate Norton equivalent resistance R_N = R_{int}lookingintoopenterminalslooking into open terminalsA-B$.
    1. Reconstruct the equivalent circuit by connecting INI_N, RNR_N, and RLR_L in parallel.
    2. Calculate load current using the Current Divider Rule (CDR):        IL=IN×RNRN+RLI_L = I_N \times \frac{R_N}{R_N + R_L}VL=IL×RLV_L = I_L \times R_L
  • Complete Numerical Step-by-Step Problem Solution:

    • Problem Circuit: A 12 V12\,\text{V} DC source supplying a network of resistors (R1=2 ΩR_1 = 2\,\Omega, R2=6 ΩR_2 = 6\,\Omega, R3=3 ΩR_3 = 3\,\Omega) connected to load resistor RL=1.5 ΩR_L = 1.5\,\Omega across terminals A-B$.\n * Step 1 & 2 (Calculate Short-Circuit Current I_N):\n * Short terminals AandandB.Resistor. ResistorR_3 = 3\,\Omegaisinparallelwithis in parallel withR_2 = 6\,\Omega\n * Parallel equivalent resistance:\n            R_{p} = \frac{3\,\Omega \times 6\,\Omega}{3\,\Omega + 6\,\Omega} = \frac{18}{9} = 2\,\Omega\n * Total resistance seen by 12\,\text{V} source:\n            R_T = 2\,\Omega + R_{p} = 2\,\Omega + 2\,\Omega = 4\,\Omega\n * Total circuit current supplied by source:\n            I_T = \frac{V}{R_T} = \frac{12\,\text{V}}{4\,\Omega} = 3\,\text{A}\n * Apply Current Divider Rule (CDR) to determine current through shorted branch A-B:\n            I_N = I_{SC} = I_T \times \frac{6\,\Omega}{3\,\Omega + 6\,\Omega} = 3\,\text{A} \times \frac{6}{9} = 2\,\text{A}\n * Step 3 (Calculate Norton Resistance R_N):\n * Deactivate the 12\,\text{V} source by replacing it with a short circuit.\n * Remove the short across terminals A-Bandlookbackintoterminalsand look back into terminalsA-B\n * The 3\,\Omegaresistorisinserieswiththeparallelcombinationofresistor is in series with the parallel combination of6\,\Omegaandand2\Omega\n * Parallel combination calculation:\n            R_{\text{parallel}} = \frac{6\,\Omega \times 2\,\Omega}{6\,\Omega + 2\,\Omega} = \frac{12}{8} = 1.5\,\Omega\n * Total Norton internal resistance:\n            R_N = 3\,\Omega + 1.5\,\Omega = 4.5\,\Omega\n * Step 4 (Calculate Load Parameters):\n * Connect I_N = 2\,\text{A},,R_N = 4.5\,\Omega,and, andR_L = 1.5\,\Omega in parallel\n * Apply Current Divider Rule to find load current I_L:\n            I_L = I_N \times \frac{R_N}{R_N + R_L} = 2\,\text{A} \times \frac{4.5\,\Omega}{4.5\,\Omega + 1.5\,\Omega} = 2\,\text{A} \times \frac{4.5}{6.0} = 1.5\,\text{A}\n * Calculate load voltage V_LacrossacrossR_L:\n            V_L = I_L \times R_L = 1.5\,\text{A} \times 1.5\,\Omega = 2.25\,\text{V}$$