Geological Instrumentation and Laboratory Technology Study Notes

Geological Instrumentation and Laboratory Technology

Preparation of Instruments and Equipment for Geological Field Work

  • Importance of Equipment Accuracy
    • As geotechnicians, it is critical to ensure that the equipment and tools for geological mapping are accurate and precise before field activities commence.
    • This verification allows for clear and useful data to be collected for subsequent analysis and interpretation in the laboratory.
  • Calibration of Instruments
    • Calibration is the fundamental first step in preparing for both surface and underground geological mapping activities.

Geological Instrument Calibration

  • Overview of Calibration
    • This lecture focuses on the calibration of several geological instruments before field mapping, including:
    1. Global Positioning System (GPS)
    2. X-Ray Fluorescence (XRF) Machine
Global Positioning System (GPS)
  • Purpose and Functionality
    • The GPS is utilized to record the coordinates and elevation of points during geological mapping, applicable to both surface and underground assessments.
  • Calibration Process Overview
    • Calibration involves taking readings of coordinates from known reference points that already have established GPS readings.
    • Any variations in readings can indicate necessary adjustments to the device.
  • Calibration Reference
    • Instructions for calibration can typically be obtained from user manuals available online, particularly from the website www.garmin.com.
GPS Calibration Procedure
  1. Purpose of Calibration
    • To verify and enhance the accuracy of the GPS receiver’s positional and height readings.
  2. Importance of Calibration
    • Errors in GPS data can lead to inaccuracies in geological mapping, geochemical surveys, geophysical surveys, and other applications.
  3. Methods of Calibration
    • Involves comparing the GPS receiver's readings with known locations and elevations.
    • Calibration may utilize field measurements or reference real-time kinematic (RTK) GPS data for precision.
Field Calibration Steps for GPS
  1. Gather Data
    • Visit known calibration points from previous surveys.
  2. Record GPS Data
    • Collect coordinates and elevations using the GPS receiver at these established points.
  3. Compare and Analyze Data
    • Compare the recorded GPS data with known accurate data, calculating errors and identifying any systematic discrepancies.
  4. Adjust Settings
    • Modify the receiver's settings, such as antenna height and datum, to minimize observed errors and enhance accuracy.
  5. Verify Calibration
    • Repeat the calibration across various locations and configurations to ensure consistent receiver performance.
Key Considerations for GPS Calibration
  • Reference Points
    • Ensure the use of reliable and accurate reference points for comparisons.
  • Antenna Height
    • Maintain accurate records of antenna height during data processing.
  • Datum
    • Select the appropriate datum based on the geographical region.
  • Software
    • Employ suitable GPS software for effective data processing and analysis.
Real-Time Kinematic (RTK) GPS Calibration
  • RTK GPS Overview
    • RTK GPS utilizes a base station to send corrections, enhancing accuracy to the centimeter level.
  • Calibration Steps
    • The calibration involves ensuring that both the base station and the roving GPS receiver are calibrated and configured correctly.
  • Verifying RTK Data
    • Compare the RTK data with established coordinates and elevations for accurate verification.
X-Ray Fluorescence (XRF) Machine Calibration
  • Introduction to XRF Machine
    • A hand-operated device utilized for identifying minerals in core or hand specimens through electromagnetic waves.
    • It records elemental percentages present within rock or core samples.
XRF Methodologies
  1. Energy Dispersive XRF (EDXRF)
  2. Wavelength Dispersive XRF (WDXRF)
  • Both methodologies possess unique advantages and disadvantages.
  • Sensitivity and Limitations
    • XRF machines are highly accurate and sensitive for all elements from magnesium upwards.
    • However, they cannot detect elements with atomic numbers lower than sodium (Z = 11), such as carbon, nitrogen, lithium, and beryllium.
XRF Calibration Criteria
  • Calibration of XRF instruments should consider:
    1. Measuring Standard Samples (MSS)
    2. Calculating Calibration Factors (CCF)
    3. Adding Calibration Factors to the Analyzer (ACF)
Measuring the Standard Samples
  • The procedure involves measuring known samples to determine elemental composition readings in the XRF machine.
    • These samples establish a baseline for accuracy adjustments; inaccuracies can result in systemic errors.
    • Measurement duration should be 120 seconds per sample with recorded reading numbers.
Calculating Calibration Factors
  • Using data obtained from standard sample measurements, plot the percentage of reported elements from the XRF Analyzer.
  • Employ linear regression functions to calculate the slope and intercept of the resultant graph based on collected data points.
Adding Calibration Factors to XRF Analyzer
  • Access the main menu of the XRF Analyzer, select common setup, then adjust calibration factors according to the operational mode.
  • Follow specific procedures outlined in the instrument's setup guide to ensure proper calibration.
Interpreting XRF Analysis Data
  • To interpret XRF data, the analyst must understand the signals produced by the sample, which should be visually represented in a graph plotting energy against intensity.
  • The interpretation of XRF spectra depends on both the requirements of the analysis and the characteristics of the sampled material.