Electric Circuits and Internal Resistance

Circuit Fundamentals: Current, Potential Difference, and Cell Connections

  • Electron Flow versus Conventional Current:

    • Electrons in an electrical circuit move through the external conducting wires from the negative terminal to the positive terminal of the cell.

    • Conventional current is historically defined and universally diagrammed as flowing in the opposite direction: from the positive terminal to the negative terminal.

    • Energy transformations within a circuit occur in stages: the electrochemical cell converts stored chemical energy into electrical potential energy, and resistive elements (such as incandescent light bulbs or resistors) convert that electrical energy into light and thermal energy.

  • Series Circuit Topologies:

    • In a series configuration, all electrical components are connected end-to-end along a single continuous conducting loop.

    • Current maintains an identical value at every point within the loop (Itotal=I1=I2=…I_{\text{total}} = I_1 = I_2 = \dots).

    • The total supply voltage is partitioned across each connected component (Vsupply=V1+V2+…V_{\text{supply}} = V_1 + V_2 + \dots).

    • A break or removal of any single component creates an open circuit, immediately interrupting current flow to all other components in the loop.

Series circuit with current flowing in a single loop
  • Parallel Circuit Topologies:

    • In a parallel configuration, components are connected across separate parallel conducting branches.

    • The total circuit current divides at each incoming junction and recombines at each outgoing junction:     I=I1+I2I = I_1 + I_2

    • Each individual branch experiences the full potential difference provided by the power supply (Vsupply=V1=V2=…V_{\text{supply}} = V_1 = V_2 = \dots).

    • If an individual branch is interrupted or disconnected, current continues to flow unimpeded through the remaining parallel paths.

Parallel circuit showing current splitting across branches
  • Connection of Electrochemical Cells:

    • Cells in Series:

    • When multiple cells are connected in series (positive terminal of one cell connected to the negative terminal of the next), each successive cell transfers additional electrical energy to each coulomb of charge.

    • The terminal potential differences sum algebraically:       Vtotal=V1+V2+V3=2 V+2 V+2 V=6 VV_{\text{total}} = V_1 + V_2 + V_3 = 2\,\text{V} + 2\,\text{V} + 2\,\text{V} = 6\,\text{V}

Three 2V cells connected in series producing 6V total
  • Cells in Parallel:

    • When cells are connected in parallel, all positive terminals share a common node, and all negative terminals share a common opposing node.

    • The total potential difference across the combination equals that of a single cell (2 V2\,\text{V}).

    • Connecting cells in parallel increases the total chemical capacity and charge capacity of the power supply, allowing the circuit to deliver current for a substantially longer duration.

Three 2V cells connected in parallel maintaining 2V total
  • Quantitative Definitions of Current and Potential Difference:

    • Electric Current (II):

    • Defined verbatim as the rate of flow of charge.

    • Expressed mathematically as:       I=qtI = \frac{q}{t}

    • Measured in amperes (A\text{A}), where one ampere corresponds to one coulomb of charge traversing a cross-section per second (1 A=1 C⋅s−11\,\text{A} = 1\,\text{C}\cdot\text{s}^{-1}).

    • Electric current can only flow when there is a continuous conducting loop and an electric potential difference established across parts of the circuit.

    • Measured using an ammeter, which must always be connected in series with the component of interest to allow the full branch current to pass through it.

    • Potential Difference (VV):

    • Defined verbatim as the work done per unit positive charge.

    • Expressed mathematically as:       V=WqV = \frac{W}{q}

    • Measured in volts (V\text{V}), where one volt is equivalent to one joule of energy transferred per coulomb of charge (1 V=1 J⋅C−11\,\text{V} = 1\,\text{J}\cdot\text{C}^{-1}).

    • Potential difference is the driving influence that impels charge carriers through a resistive medium.

    • Measured using a voltmeter, which must always be connected in parallel across two specific test points.

    • Terminology Distinction: Voltage serves as a general term representing electrical potential at a single point or across an element, whereas potential difference is the more technically precise term denoting the difference in electrical potential between two designated points.

  • Semiconductor Diodes and Directional Current Flow:

    • A diode is a non-linear circuit component that permits current flow in only one direction (forward bias) while presenting near-infinite resistance in the opposite direction (reverse bias).

    • Worked Example (Bulbs and Diodes Network):

Circuit diagram with two bulbs and three diodes connected to a DC source
  • Circuit Configuration: A DC battery with a closed switch SS supplies current to two parallel branches containing Bulb A and Bulb B, preceded and configured with three semiconductor diodes.

  • Conduction Analysis:

    • Conventional current departs from the positive terminal and moves clockwise through the right-hand bus wire through closed switch SS.

    • At the parallel junction, current attempts to divide into branch A and branch B.

    • Branch A contains a diode pointing in the reverse direction relative to incoming current flow (reverse-biased), preventing current from reaching Bulb A.

    • Branch B contains a diode pointing in the direction of conventional current (forward-biased), allowing current to pass freely through Bulb B.

    • Current from Bulb B enters the common return wire and passes through the forward-biased third diode back to the battery's negative terminal.

  • Conclusion: Only Bulb B lights up.

Ohm's Law and Conductor Behavior

  • The Concept of Electrical Resistance:

    • Resistance is defined verbatim as a material's opposition to the flow of electric charge.

    • Quantified in units of ohms (Ω\Omega).

    • Resistance is calculated as the ratio of potential difference across a conductor to the resultant current through it:     R=VIR = \frac{V}{I}

    • As charge carriers collide with lattice ions within a resistive material, electrical potential energy is dissipated as thermal energy.

  • Ohm's Law Formulation:

    • Stated verbatim: The current through a conductor is directly proportional to the potential difference across the conductor at constant temperature.

    • Expressed as:     I∝V(provided T is constant)I \propto V \quad \text{(provided } T \text{ is constant)}

  • Ohmic versus Non-Ohmic Conductors:

    • Ohmic Conductors:

    • Obey Ohm's law over their operating range, exhibiting a constant resistance at constant temperature.

    • Their current versus potential difference (I−VI-V) graph is a linear straight line that passes directly through the origin (0,00,0).

    • The gradient of an I−VI-V graph for an ohmic component is inversely proportional to resistance:       Gradient=IV=1R\text{Gradient} = \frac{I}{V} = \frac{1}{R}

    • Light Bulb Filament:

    • A non-ohmic conductor whose resistance increases significantly as it heats up.

    • On an I−VI-V plot, the line curves and flattens out toward the voltage axis as VV increases, reflecting an increasing resistance (decreasing gradient).

    • Thermistor (Negative Temperature Coefficient - NTC):

    • A non-ohmic semiconductor device whose resistance decreases markedly as its temperature increases.

    • On an I−VI-V plot, as the thermistor heats up from increasing current, its curve bends sharply upward toward the current axis, showing a rapidly increasing current due to reduced resistance.

I-V characteristic curves for an ohmic conductor, light bulb filament, and thermistor
  • Analysis of I-V Characteristic Graphs:

Four distinct I-V characteristic curves labeled A, B, C, and D
  • Worked Problem: Given four characteristic curves (A, B, C, D) on an II versus VV axis system, identify which line depicts the behaviour of the ohmic resistor with the highest resistance.

  • Evaluation:

    • Curves A and D represent non-ohmic devices due to their non-linear curvature.

    • Lines B and C represent ohmic resistors because both are straight lines passing through the origin.

    • Since the slope of an I−VI-V line represents 1R\frac{1}{R}, a higher resistance corresponds to a smaller numerical gradient (a shallower slope).

    • Line C exhibits a shallower slope than line B; therefore, Line C represents the ohmic resistor with the highest resistance.

Circuit Laws and Network Calculations

  • Fundamental Current, Potential Difference, and Resistance Relationships:

Summary diagram of current, potential difference, and resistance relationships
  • Current Relationships:

    • Series: Itotal=I1=I2I_{\text{total}} = I_1 = I_2

    • Parallel: Itotal=I1+I2I_{\text{total}} = I_1 + I_2

    • Combination: Current divides across parallel branches, but remains uniform across series components along any individual branch.

  • Potential Difference Relationships:

    • Series: Vtotal=V1+V2V_{\text{total}} = V_1 + V_2

    • Parallel: Vtotal=V1=V2=V3V_{\text{total}} = V_1 = V_2 = V_3

    • Combination: The overall potential difference across parallel branches matches the supply branch voltage, while series components inside a branch share that branch's voltage (Vbranch=V1+V2V_{\text{branch}} = V_1 + V_2).

  • Resistance Relationships:

    • Series: Rtotal=R1+R2R_{\text{total}} = R_1 + R_2

    • Parallel: 1Rp=1R1+1R2  ⟹  Rp=R1R2R1+R2\frac{1}{R_p} = \frac{1}{R_1} + \frac{1}{R_2} \implies R_p = \frac{R_1 R_2}{R_1 + R_2}

    • Combination: Parallel combinations containing series branches calculate branch resistances first (Rbranch=R1+R2R_{\text{branch}} = R_1 + R_2) before applying parallel reciprocal summation.

    • Diagnostic Circuit Analysis (Foundational Revision):

Combination circuit testing ammeter readings across multiple nodes
  • Missing Ammeter Calculations:

    • Main branch ammeter reads 3 A3\,\text{A}.

    • First parallel cluster splits into two branches: lower branch ammeter reads 2 A2\,\text{A}. Therefore, upper branch ammeter A2=3 A−2 A=1 AA_2 = 3\,\text{A} - 2\,\text{A} = 1\,\text{A}.

    • Recombination at ammeter A3A_3 carries total current: A3=3 AA_3 = 3\,\text{A}.

    • Battery return ammeter A1A_1 carries total current: A1=3 AA_1 = 3\,\text{A}.

    • Second parallel cluster splits into three branches with given currents of 0.5 A0.5\,\text{A} and 1 A1\,\text{A}. The remaining ammeter A4A_4 reads:     A4=3 A−(0.5 A+1 A)=1.5 AA_4 = 3\,\text{A} - (0.5\,\text{A} + 1\,\text{A}) = 1.5\,\text{A}

Series resistor network with potential differences indicated
  • Series Potential Difference Network Calculations (Points A through F):

    • Given segment drops: VBC=2 VV_{BC} = 2\,\text{V}, VCD=4 VV_{CD} = 4\,\text{V}, VDE=3 VV_{DE} = 3\,\text{V}.

    • VBD=VBC+VCD=2 V+4 V=6 VV_{BD} = V_{BC} + V_{CD} = 2\,\text{V} + 4\,\text{V} = 6\,\text{V}

    • VCE=VCD+VDE=4 V+3 V=7 VV_{CE} = V_{CD} + V_{DE} = 4\,\text{V} + 3\,\text{V} = 7\,\text{V}

    • VBE=VBC+VCD+VDE=2 V+4 V+3 V=9 VV_{BE} = V_{BC} + V_{CD} + V_{DE} = 2\,\text{V} + 4\,\text{V} + 3\,\text{V} = 9\,\text{V}

    • VAB=0 VV_{AB} = 0\,\text{V} (across ideal conductor)

    • VEF=0 VV_{EF} = 0\,\text{V} (across ideal conductor)

    • VAF=VBE=9 VV_{AF} = V_{BE} = 9\,\text{V} (full battery terminal voltage)

    • VAD=VAB+VBC+VCD=0 V+2 V+4 V=6 VV_{AD} = V_{AB} + V_{BC} + V_{CD} = 0\,\text{V} + 2\,\text{V} + 4\,\text{V} = 6\,\text{V}

    • VBF=VBE+VEF=9 V+0 V=9 VV_{BF} = V_{BE} + V_{EF} = 9\,\text{V} + 0\,\text{V} = 9\,\text{V}

Parallel resistor network connected across points A through H
  • Parallel Potential Difference Network Calculations (Points A through H):

    • Bottom branch voltmeter reads 6 V6\,\text{V}.

    • VCF=6 VV_{CF} = 6\,\text{V} (parallel branch voltage)

    • VBG=6 VV_{BG} = 6\,\text{V} (parallel branch voltage)

    • VAH=6 VV_{AH} = 6\,\text{V} (battery supply voltage)

    • VAB=0 VV_{AB} = 0\,\text{V} (ideal conductor wire)

    • VAG=VAB+VBG=0 V+6 V=6 VV_{AG} = V_{AB} + V_{BG} = 0\,\text{V} + 6\,\text{V} = 6\,\text{V}

    • VBE=6 VV_{BE} = 6\,\text{V} (node B is on the positive rail, node E is on the negative rail)

    • VDG=6 VV_{DG} = 6\,\text{V} (node D is on the positive rail, node G is on the negative rail)

    • VEH=0 VV_{EH} = 0\,\text{V} (ideal conductor along the negative bus)

    • Comprehensive Analysis of Circuits 1 through 6:

Circuit 1 diagram with series resistors and known voltage of 10V
  • Circuit 1:

    • Total battery potential difference = 10 V10\,\text{V}.

    • Circuit is a single series loop with ammeter reading 10 A10\,\text{A}.

    • Current throughout the loop is uniform: A2=10 AA_2 = 10\,\text{A}.

    • Voltage across the 0.4 Ω0.4\,\Omega resistor: V3=I×R=10 A×0.4 Ω=4 VV_3 = I \times R = 10\,\text{A} \times 0.4\,\Omega = 4\,\text{V}.

    • Voltmeter across resistor R3R_3 is given as 4 V4\,\text{V}.

    • Applying Kirchhoff's loop rule: Vbattery=V2+V3+VR3  ⟹  10 V=V2+4 V+4 V  ⟹  V2=2 VV_{\text{battery}} = V_2 + V_3 + V_{R_3} \implies 10\,\text{V} = V_2 + 4\,\text{V} + 4\,\text{V} \implies V_2 = 2\,\text{V}.

Circuit 2 diagram with three series resistors connected to an 8V battery
  • Circuit 2:

    • Battery potential difference = 8 V8\,\text{V}; series resistors are 2 Ω2\,\Omega, 3 Ω3\,\Omega, and 5 Ω5\,\Omega.

    • Total resistance: Rtotal=2 Ω+3 Ω+5 Ω=10 ΩR_{\text{total}} = 2\,\Omega + 3\,\Omega + 5\,\Omega = 10\,\Omega.

    • Main loop current: I=VRtotal=8 V10 Ω=0.8 AI = \frac{V}{R_{\text{total}}} = \frac{8\,\text{V}}{10\,\Omega} = 0.8\,\text{A}.

    • Ammeter readings: A1=0.8 AA_1 = 0.8\,\text{A}, A2=0.8 AA_2 = 0.8\,\text{A}.

    • Voltmeter drops across individual resistors:     V2=I×2 Ω=0.8 A×2 Ω=1.6 VV_2 = I \times 2\,\Omega = 0.8\,\text{A} \times 2\,\Omega = 1.6\,\text{V}     V3=I×3 Ω=0.8 A×3 Ω=2.4 VV_3 = I \times 3\,\Omega = 0.8\,\text{A} \times 3\,\Omega = 2.4\,\text{V}     V4=I×5 Ω=0.8 A×5 Ω=4.0 VV_4 = I \times 5\,\Omega = 0.8\,\text{A} \times 5\,\Omega = 4.0\,\text{V}

Circuit 3 diagram with series resistors and 3A current
  • Circuit 3:

    • Series circuit with resistors 5 Ω5\,\Omega, 1 Ω1\,\Omega, and 2 Ω2\,\Omega, with an ammeter measuring 3 A3\,\text{A}.

    • Loop current: A2=3 AA_2 = 3\,\text{A}.

    • Component voltage drops:     V2=3 A×5 Ω=15 VV_2 = 3\,\text{A} \times 5\,\Omega = 15\,\text{V}     V3=3 A×1 Ω=3 VV_3 = 3\,\text{A} \times 1\,\Omega = 3\,\text{V}     V4=3 A×2 Ω=6 VV_4 = 3\,\text{A} \times 2\,\Omega = 6\,\text{V}

    • Supply voltage: V1=V2+V3+V4=15 V+3 V+6 V=24 VV_1 = V_2 + V_3 + V_4 = 15\,\text{V} + 3\,\text{V} + 6\,\text{V} = 24\,\text{V}.

Circuit 4 diagram with combination series-parallel network and 5V supply
  • Circuit 4:

    • Supply voltage = 5 V5\,\text{V}.

    • Parallel section consists of a top branch with 1 Ω1\,\Omega carrying 1 A1\,\text{A}, and a bottom branch with 4 Ω4\,\Omega monitored by ammeter A2A_2 and voltmeter V3V_3.

    • Branch voltage across parallel bank: Vp=1 A×1 Ω=1 VV_p = 1\,\text{A} \times 1\,\Omega = 1\,\text{V}. Hence, V3=1 VV_3 = 1\,\text{V}.

    • Current through bottom branch: A2=Vp4 Ω=1 V4 Ω=0.25 AA_2 = \frac{V_p}{4\,\Omega} = \frac{1\,\text{V}}{4\,\Omega} = 0.25\,\text{A}.

    • Total circuit current: Itotal=1 A+0.25 A=1.25 AI_{\text{total}} = 1\,\text{A} + 0.25\,\text{A} = 1.25\,\text{A}. Hence, A1=1.25 AA_1 = 1.25\,\text{A} and A4=1.25 AA_4 = 1.25\,\text{A}.

    • Series voltage drop across resistor R4R_4 is given as 1 V1\,\text{V}.

    • Drop across input resistor R1R_1: V2=5 V−(Vp+V4)=5 V−(1 V+1 V)=3 VV_2 = 5\,\text{V} - (V_p + V_4) = 5\,\text{V} - (1\,\text{V} + 1\,\text{V}) = 3\,\text{V}.

Circuit 5 diagram with combination circuit and 12V supply
  • Circuit 5:

    • Battery potential difference = 12 V12\,\text{V}.

    • Parallel sub-circuit has a top branch carrying 1 A1\,\text{A} through a 3 Ω3\,\Omega resistor, and a lower branch carrying 3 A3\,\text{A} through R3R_3.

    • Parallel bank potential difference: Vp=1 A×3 Ω=3 VV_p = 1\,\text{A} \times 3\,\Omega = 3\,\text{V}. Hence, V3=3 VV_3 = 3\,\text{V}.

    • Resistance of R3R_3: R3=VpI3=3 V3 A=1 ΩR_3 = \frac{V_p}{I_3} = \frac{3\,\text{V}}{3\,\text{A}} = 1\,\Omega.

    • Total current entering and leaving parallel bank: Itotal=1 A+3 A=4 AI_{\text{total}} = 1\,\text{A} + 3\,\text{A} = 4\,\text{A}. Hence, A1=4 AA_1 = 4\,\text{A} and A4=4 AA_4 = 4\,\text{A}.

    • Voltage drop across the initial series 1 Ω1\,\Omega resistor: V2=Itotal×1 Ω=4 A×1 Ω=4 VV_2 = I_{\text{total}} \times 1\,\Omega = 4\,\text{A} \times 1\,\Omega = 4\,\text{V}.

    • Voltage drop across trailing resistor R4R_4: V4=12 V−(V2+Vp)=12 V−(4 V+3 V)=5 VV_4 = 12\,\text{V} - (V_2 + V_p) = 12\,\text{V} - (4\,\text{V} + 3\,\text{V}) = 5\,\text{V}.

Circuit 6 diagram with combination circuit and 10V supply
  • Circuit 6:

    • Battery supply = 10 V10\,\text{V}; series components are 2.4 Ω2.4\,\Omega (V2V_2) and 0.8 Ω0.8\,\Omega (V4V_4); parallel bank consists of 4 Ω4\,\Omega (A2A_2) and 1 Ω1\,\Omega (A3,V3A_3, V_3).

    • Equivalent parallel resistance: Rp=4 Ω×1 Ω4 Ω+1 Ω=45 Ω=0.8 ΩR_p = \frac{4\,\Omega \times 1\,\Omega}{4\,\Omega + 1\,\Omega} = \frac{4}{5}\,\Omega = 0.8\,\Omega.

    • Total circuit resistance: Rtotal=2.4 Ω+0.8 Ω+0.8 Ω=4.0 ΩR_{\text{total}} = 2.4\,\Omega + 0.8\,\Omega + 0.8\,\Omega = 4.0\,\Omega.

    • Total current: Itotal=10 V4.0 Ω=2.5 AI_{\text{total}} = \frac{10\,\text{V}}{4.0\,\Omega} = 2.5\,\text{A}. Thus, A1=2.5 AA_1 = 2.5\,\text{A} and A4=2.5 AA_4 = 2.5\,\text{A}.

    • Voltage drops:       V2=2.5 A×2.4 Ω=6.0 VV_2 = 2.5\,\text{A} \times 2.4\,\Omega = 6.0\,\text{V}       V4=2.5 A×0.8 Ω=2.0 VV_4 = 2.5\,\text{A} \times 0.8\,\Omega = 2.0\,\text{V}       V3=Vp=2.5 A×0.8 Ω=2.0 VV_3 = V_p = 2.5\,\text{A} \times 0.8\,\Omega = 2.0\,\text{V}

    • Branch currents:       A2=Vp4 Ω=2.0 V4 Ω=0.5 AA_2 = \frac{V_p}{4\,\Omega} = \frac{2.0\,\text{V}}{4\,\Omega} = 0.5\,\text{A}       A3=Vp1 Ω=2.0 V1 Ω=2.0 AA_3 = \frac{V_p}{1\,\Omega} = \frac{2.0\,\text{V}}{1\,\Omega} = 2.0\,\text{A}

    • Voltmeters in Non-Standard Placements (Bridge Network Analysis):

Bridge network across 12V battery with nodes P, Q, R, and S
  • Network Parameters: Battery supplies 12 V12\,\text{V}. Two parallel branches extend between nodes P and R.

    • Top Branch: Resistor of 2 Ω2\,\Omega between P and Q; resistor of 4 Ω4\,\Omega between Q and R.

    • Bottom Branch: Resistor of 2 Ω2\,\Omega between P and S; resistor of 2 Ω2\,\Omega between S and R.

  • Branch Current Calculations:

    • Top branch resistance: Rtop=2 Ω+4 Ω=6 ΩR_{\text{top}} = 2\,\Omega + 4\,\Omega = 6\,\Omega.

    • Top branch current: Itop=12 V6 Ω=2 AI_{\text{top}} = \frac{12\,\text{V}}{6\,\Omega} = 2\,\text{A}.

    • Bottom branch resistance: Rbottom=2 Ω+2 Ω=4 ΩR_{\text{bottom}} = 2\,\Omega + 2\,\Omega = 4\,\Omega.

    • Bottom branch current: Ibottom=12 V4 Ω=3 AI_{\text{bottom}} = \frac{12\,\text{V}}{4\,\Omega} = 3\,\text{A}.

  • Potential Calculations Between Terminals:

    • Between P and Q: VPQ=Itop×2 Ω=2 A×2 Ω=4 VV_{PQ} = I_{\text{top}} \times 2\,\Omega = 2\,\text{A} \times 2\,\Omega = 4\,\text{V}.

    • Between Q and R: VQR=Itop×4 Ω=2 A×4 Ω=8 VV_{QR} = I_{\text{top}} \times 4\,\Omega = 2\,\text{A} \times 4\,\Omega = 8\,\text{V}.

    • Between P and S: VPS=Ibottom×2 Ω=3 A×2 Ω=6 VV_{PS} = I_{\text{bottom}} \times 2\,\Omega = 3\,\text{A} \times 2\,\Omega = 6\,\text{V}.

    • Between S and R: VSR=Ibottom×2 Ω=3 A×2 Ω=6 VV_{SR} = I_{\text{bottom}} \times 2\,\Omega = 3\,\text{A} \times 2\,\Omega = 6\,\text{V}.

    • Between Q and S: Taking potential at P as 12 V12\,\text{V}, potential at Q is VQ=12 V−4 V=8 VV_Q = 12\,\text{V} - 4\,\text{V} = 8\,\text{V}; potential at S is VS=12 V−6 V=6 VV_S = 12\,\text{V} - 6\,\text{V} = 6\,\text{V}. Hence, the potential difference is:       VQS=∣VQ−VS∣=∣8 V−6 V∣=2 VV_{QS} = |V_Q - V_S| = |8\,\text{V} - 6\,\text{V}| = 2\,\text{V}

    • Between P and R: Directly across the battery supply terminals:       VPR=12 VV_{PR} = 12\,\text{V}

    • Executive Summary Synthesis of Series and Parallel Properties:

  • Series Circuits:

    • Have only one path for electric current.

    • The current is the same at every point in the circuit.

    • The potential difference is shared (divided) proportionally between the components.

    • Total resistance is calculated by adding the individual resistances.

    • Adding more resistors in series increases total equivalent resistance.

    • As total resistance increases, total current decreases.

    • Identical light bulbs become dimmer when more bulbs are added in series.

    • If one component breaks, all components immediately stop working.

  • Parallel Circuits:

    • Have two or more independent paths for electric current.

    • Potential difference is the same across every branch.

    • Total current splits between branches inversely proportional to branch resistance.

    • Total current is found by adding the currents across all individual branches.

    • Adding another parallel branch decreases total equivalent resistance.

    • As total resistance decreases, total current supplied by the source increases.

    • Identical light bulbs connected in parallel maintain the same brightness.

    • If one branch breaks, all other branches continue working.

Electrical Energy, Power, and Tariff Calculations

  • Concepts and Mathematical Formulations of Energy and Power:

    • Electrical work (WW) represents the total quantity of energy transferred when charge is accelerated through an electrical component.

    • Expressed via Joule's law relationships:     W=VItW = V I t     W=I2RtW = I^2 R t     W=V2RtW = \frac{V^2}{R} t

    • Electrical power (PP) describes how rapidly an appliance converts electrical potential energy into alternative energy forms.

    • Stated verbatim: Electrical power dissipated in a device is equal to the product of the potential difference across the device and current flowing through it.

    • Formulated mathematically as:     P=VIP = V I     P=I2RP = I^2 R     P=V2RP = \frac{V^2}{R}

    • Measured in watts (W\text{W}), where one watt equals one joule transferred per second (1 W=1 J⋅s−11\,\text{W} = 1\,\text{J}\cdot\text{s}^{-1}).

  • Comparative Summary of Core Electrical Quantities:

    • Electromotive Force (emf): Total energy supplied by a cell or power source per unit charge (J⋅C−1\text{J}\cdot\text{C}^{-1} or V\text{V}).

    • Potential Difference (Voltage): Energy transferred/dissipated across a component per unit charge (J⋅C−1\text{J}\cdot\text{C}^{-1} or V\text{V}).

    • Energy (WW): Total cumulative amount of work transferred over time, measured in joules (J\text{J}).

    • Power (PP): The time rate of energy transfer, measured in watts (W\text{W} or J⋅s−1\text{J}\cdot\text{s}^{-1}).

  • Domestic Electrical Costing (Kilowatt-Hour Billing):

    • The joule is an inconveniently small unit for municipal power utility billing; suppliers use the kilowatt-hour (kWh\text{kWh}).

    • Defined verbatim: The kilowatt hour (kWh) is a unit of energy and 1 kWh is the amount of energy used when 1 kilowatt of electricity is used for 1 hour.

    • Physical equivalence to SI units:     1 kWh=1000 W×3600 s=3.6×106 J=3.6 MJ1\,\text{kWh} = 1000\,\text{W} \times 3600\,\text{s} = 3.6 \times 10^6\,\text{J} = 3.6\,\text{MJ}

    • Cost calculation formula:     Cost=energy used (kWh)×price per kWh\text{Cost} = \text{energy used (kWh)} \times \text{price per kWh}

  • Worked Numerical Examples:

Circuit diagram with parallel resistor R and 60W bulb powered by 12V supply
  • Example 1: Energy and Power Calculations:

    • Given: Supply potential difference V=12 VV = 12\,\text{V} (negligible internal resistance), main ammeter reads Itotal=6 AI_{\text{total}} = 6\,\text{A}, bulb rated at Pbulb=60 WP_{\text{bulb}} = 60\,\text{W}.

    • 1.1 Calculate the resistance of the bulb:
          P=V2Rbulb  ⟹  60=122Rbulb  ⟹  Rbulb=14460=2.4 ΩP = \frac{V^2}{R_{\text{bulb}}} \implies 60 = \frac{12^2}{R_{\text{bulb}}} \implies R_{\text{bulb}} = \frac{144}{60} = 2.4\,\Omega

    • 1.2 Calculate the resistance of resistor R:
          Current drawn by bulb: Ibulb=PV=60 W12 V=5 AI_{\text{bulb}} = \frac{P}{V} = \frac{60\,\text{W}}{12\,\text{V}} = 5\,\text{A}.     Current through resistor RR: IR=Itotal−Ibulb=6 A−5 A=1 AI_R = I_{\text{total}} - I_{\text{bulb}} = 6\,\text{A} - 5\,\text{A} = 1\,\text{A}.     Applying Ohm's law:     R=VIR=12 V1 A=12 ΩR = \frac{V}{I_R} = \frac{12\,\text{V}}{1\,\text{A}} = 12\,\Omega

    • 1.3 Determine energy consumed by resistor R in 2 minutes:
          Convert time to seconds: t=2×60=120 st = 2 \times 60 = 120\,\text{s}.     W=VIRt=12 V×1 A×120 s=1440 JW = V I_R t = 12\,\text{V} \times 1\,\text{A} \times 120\,\text{s} = 1440\,\text{J}

  • Example 2: Cost of Electricity Calculation:

    • Given: Electric heater resistance R=40 ΩR = 40\,\Omega, operating potential difference V=220 VV = 220\,\text{V}, unit tariff = R1.80 per kWh\text{R}1.80\,\text{per kWh}, prepaid budget = R100\text{R}100.

    • Determine permissible operating time:
          Power of the heater:     P=V2R=220240=4840040=1210 W=1.21 kWP = \frac{V^2}{R} = \frac{220^2}{40} = \frac{48400}{40} = 1210\,\text{W} = 1.21\,\text{kW}     Total electrical energy purchased:     Energy (kWh)=CostTariff=1001.80=55.556 kWh\text{Energy (kWh)} = \frac{\text{Cost}}{\text{Tariff}} = \frac{100}{1.80} = 55.556\,\text{kWh}     Operating duration:     t=EnergyP=55.556 kWh1.21 kW≈45.9 hourst = \frac{\text{Energy}}{P} = \frac{55.556\,\text{kWh}}{1.21\,\text{kW}} \approx 45.9\,\text{hours}

Internal Resistance, Emf, and Experimental Determination

  • Physical Concept of Internal Resistance:

    • Real cells and batteries possess an intrinsic internal resistance (rr) caused by the physical materials, electrodes, and chemical electrolytes within the casing.

    • When electric current flows through the battery, some electrical potential energy is dissipated as heat internally due to this resistance.

    • Defined verbatim: Define emf as the total energy supplied per coulomb of charge by the cell.

    • The internal potential drop is referred to as "lost volts":     Vint=Vlost=IrV_{\text{int}} = V_{\text{lost}} = Ir

    • The terminal potential difference (VextV_{\text{ext}} or VloadV_{\text{load}}) available to the external circuit is always less than the total emf when current flows:     Vext=emf−IrV_{\text{ext}} = \text{emf} - Ir

    • Stated verbatim: The sum of the voltages across the external circuit plus the voltage across the internal resistance is equal to the emf.     emf=Vload+Vinternal resistance\text{emf} = V_{\text{load}} + V_{\text{internal resistance}}     emf=I(Rext+r)\text{emf} = I(R_{\text{ext}} + r)

Circuit diagram with internal resistance and corresponding electrical potential energy profile
  • Circuit Potential Distribution:

    • As charge carriers traverse the chemical cell, their electric potential rises abruptly by the cell's total emf\text{emf}.

    • Moving across internal resistance rr, potential drops immediately by Vint=IrV_{\text{int}} = Ir, establishing terminal potential difference VextV_{\text{ext}}.

    • Along ideal connecting conductors, potential remains unchanged.

    • Across external resistance RextR_{\text{ext}}, potential drops by Vext=IRextV_{\text{ext}} = I R_{\text{ext}}, returning to the reference baseline of 0 V0\,\text{V}.

  • Practical Investigation: Terminal Potential Difference and Current:

    • Investigation Question: How does the terminal potential difference of a battery change as the current through the circuit increases?

    • Aim: To investigate the relationship between the terminal potential difference of a battery and the current it supplies.

    • Hypothesis: As the current drawn from the battery increases, the terminal potential difference across the battery decreases linearly.

    • Variables:

    • Independent Variable: Electric current (II), varied via a rheostat.

    • Dependent Variable: Terminal potential difference (VV), measured across battery terminals.

    • Controlled Variables: Temperature of the battery (kept constant by closing switch only briefly), battery emf, internal resistance.

Apparatus setup for determining emf and internal resistance
  • Apparatus: Battery/cell, variable resistor (rheostat), ammeter, voltmeter, switch, connecting leads.

  • Method:

    1. Connect the ammeter, battery, switch, and rheostat in a single series loop.

    2. Connect the voltmeter in parallel directly across the battery terminals.

    3. Set the rheostat to its maximum resistance position to ensure minimal current on initial closure.

    4. Close the switch briefly.

    5. Read and record current II from the ammeter and terminal potential difference VV from the voltmeter.

    6. Open the switch immediately to avoid internal heating.

    7. Decrease rheostat resistance slightly.

    8. Close switch briefly and record new paired readings (I,VI, V).

    9. Repeat procedure until at least six distinct data pairs are obtained.

  • Mathematical and Graphical Analysis:

    • Plot terminal potential difference VV on the vertical axis against current II on the horizontal axis.

    • Express equation in slope-intercept form (y=mx+cy = mx + c):       V=−rI+emfV = -r I + \text{emf}

    • The y-intercept represents the electromotive force (emf) of the battery.

    • The gradient represents the negative of the internal resistance (Gradient=−r  ⟹  r=−gradient\text{Gradient} = -r \implies r = -\text{gradient}).

  • Headline Conclusion: As current increases, internal lost voltage and heating increase, leaving less voltage available to the external circuit.

    • Worked Examples with Internal Resistance:

Circuit with 26V battery, internal resistance, and mixed resistor network
  • Example 1: Parameter Determination and Fault Analysis:

    • Given: Battery with emf=26 V\text{emf} = 26\,\text{V} and unknown internal resistance rr. External network contains a series 4 Ω4\,\Omega resistor and a parallel branch pair of 6 Ω6\,\Omega and 10 Ω10\,\Omega. Ammeter reads I=3 AI = 3\,\text{A}.

    • 1.1 Calculate effective resistance of the circuit (RextR_{\text{ext}}):
          Rp=6 Ω×10 Ω6 Ω+10 Ω=6016=3.75 ΩR_p = \frac{6\,\Omega \times 10\,\Omega}{6\,\Omega + 10\,\Omega} = \frac{60}{16} = 3.75\,\Omega     Rext=4 Ω+3.75 Ω=7.75 ΩR_{\text{ext}} = 4\,\Omega + 3.75\,\Omega = 7.75\,\Omega

    • 1.2 Determine internal resistance of the battery (rr):
          emf=I(Rext+r)\text{emf} = I(R_{\text{ext}} + r)     26=3(7.75+r)  ⟹  7.75+r=263≈8.667 Ω26 = 3(7.75 + r) \implies 7.75 + r = \frac{26}{3} \approx 8.667\,\Omega     r=8.667−7.75=0.9167 Ω≈0.92 Ωr = 8.667 - 7.75 = 0.9167\,\Omega \approx 0.92\,\Omega

    • 1.3 Behavior if the 6 Ω6\,\Omega resistor burns out:

    • Burning out the 6 Ω6\,\Omega resistor removes that parallel path, leaving only the 10 Ω10\,\Omega resistor in series with the 4 Ω4\,\Omega resistor.

    • External resistance increases (Rext=4+10=14 ΩR_{\text{ext}} = 4 + 10 = 14\,\Omega).

    • Total circuit current decreases according to I=emfRext+rI = \frac{\text{emf}}{R_{\text{ext}} + r}.

    • The internal lost voltage drop decreases according to Vlost=IrV_{\text{lost}} = Ir.

    • Therefore, by Vext=emf−IrV_{\text{ext}} = \text{emf} - Ir, the voltmeter reading across the battery terminals increases.

    • 1.4 Voltmeter reading if the 4 Ω4\,\Omega resistor burns out:

    • The 4 Ω4\,\Omega resistor is located in the main series branch; burning out creates an open circuit.

    • Circuit current drops to zero (I=0 AI = 0\,\text{A}).

    • With zero current, lost volts become zero (Vint=0 A×r=0 VV_{\text{int}} = 0\,\text{A} \times r = 0\,\text{V}).

    • The voltmeter measures open-circuit terminal voltage, which equals the total emf: 26 V26\,\text{V}.

Complex circuit with four cells, two bulbs, unknown resistor R, and switch S
  • Example 2: Multi-Component Network with Switch Transitions:

    • Given: Battery composed of four identical cells in series, each having internal resistance r=0.5 Ωr = 0.5\,\Omega (rtotal=4×0.5 Ω=2.0 Ωr_{\text{total}} = 4 \times 0.5\,\Omega = 2.0\,\Omega). Switch SS is initially open. Voltmeter V2V_2 across the parallel bank reads 8 V8\,\text{V}. Main ammeter reads 2 A2\,\text{A}.

    • 3.1 Calculate current passing through the 10 W10\,\text{W} bulb:
          P=VI  ⟹  Ibulb=PV=10 W8 V=1.25 AP = V I \implies I_{\text{bulb}} = \frac{P}{V} = \frac{10\,\text{W}}{8\,\text{V}} = 1.25\,\text{A}

    • 3.2 Calculate resistance of the 12 W12\,\text{W} bulb:
          With switch SS open, the entire main current of 2 A2\,\text{A} flows through the 12 W12\,\text{W} bulb:     P=I2R  ⟹  12 W=(2 A)2Rbulb  ⟹  Rbulb=124=3 ΩP = I^2 R \implies 12\,\text{W} = (2\,\text{A})^2 R_{\text{bulb}} \implies R_{\text{bulb}} = \frac{12}{4} = 3\,\Omega

    • 3.3 Calculate resistance of unknown resistor R:
          Current dividing rule: IR=Itotal−Ibulb=2 A−1.25 A=0.75 AI_R = I_{\text{total}} - I_{\text{bulb}} = 2\,\text{A} - 1.25\,\text{A} = 0.75\,\text{A}.     R=V2IR=8 V0.75 A=834=323 Ω≈10.67 ΩR = \frac{V_2}{I_R} = \frac{8\,\text{V}}{0.75\,\text{A}} = \frac{8}{\frac{3}{4}} = \frac{32}{3}\,\Omega \approx 10.67\,\Omega

    • 3.4 Calculate the reading on voltmeter V1V_1 (terminal voltage):
          Total external voltage is the sum of all series sub-drops:     V1=Vparallel+V3 Ω+V12 W bulbV_1 = V_{\text{parallel}} + V_{3\,\Omega} + V_{12\,\text{W bulb}}     V3 Ω=I×3 Ω=2 A×3 Ω=6 VV_{3\,\Omega} = I \times 3\,\Omega = 2\,\text{A} \times 3\,\Omega = 6\,\text{V}     V12 W bulb=I×Rbulb=2 A×3 Ω=6 VV_{12\,\text{W bulb}} = I \times R_{\text{bulb}} = 2\,\text{A} \times 3\,\Omega = 6\,\text{V}     V1=8 V+6 V+6 V=20 VV_1 = 8\,\text{V} + 6\,\text{V} + 6\,\text{V} = 20\,\text{V}

    • 3.5 Calculate total emf of the battery:
          Vint=I×rtotal=2 A×2.0 Ω=4 VV_{\text{int}} = I \times r_{\text{total}} = 2\,\text{A} \times 2.0\,\Omega = 4\,\text{V}     emf=Vext+Vint=20 V+4 V=24 V\text{emf} = V_{\text{ext}} + V_{\text{int}} = 20\,\text{V} + 4\,\text{V} = 24\,\text{V}

    • 3.6 Reading on voltmeter V3V_3 after switch S is closed:
          Switch SS is wired in parallel directly across the 12 W12\,\text{W} bulb and voltmeter V3V_3. Closing switch SS establishes a zero-resistance bypass path, short-circuiting that component. The reading drops to 0 V0\,\text{V}.

    • 3.7 Explanation of change in reading on voltmeter V1V_1 when switch S is closed:

    • Bypassing the 12 W12\,\text{W} bulb removes its 3 Ω3\,\Omega resistance, causing total external circuit resistance RextR_{\text{ext}} to decrease.

    • Total circuit current increases according to:       I=emfRext+rI = \frac{\text{emf}}{R_{\text{ext}} + r}

    • An increased current causes a higher internal voltage drop (lost volts) across the internal resistance according to:       Vint=IrV_{\text{int}} = Ir

    • As shown by the terminal voltage relationship:       V1=emf−IrV_1 = \text{emf} - Ir

    • With higher lost volts subtracted from the constant emf, the terminal potential difference reading on V1V_1 decreases.