O2 Delivery Devices
Low flow devices:
Nasal Cannula: Delivers 24-40% O2 at flow rates of 1-6 L/min. To calculate the amount of FiO2, start at an FiO2 of 20% and add 4%, so 1 L would be 24%. (Stable patients)
Simple O2 Mask: Delivers 35-50% O2 at flow rates of 5-10 L/min, minimum flow rate of 5 L/min is required to prevent buildup of exhaled CO2 in the mask. (Moderate hypoxemia; patient tolerates face mask)
Partial Rebreathing Mask: Delivers 40-70% O2 at flow rates of 10-15 L/min.
Nonrebreathing Mask: Delivers 60-80% O2 at flow rates of 10-15 L/min. (Severe hypoxemia prior to intubation)
High flow devices:
Air-entrainment Mask: Delivers 24-50% O2 depending on the size of jet and entrainment port.
The larger the entrainment port, the more air entrained and the lower the FiO2
Likewise, the smaller the entrainment port, the less air entrained and the higher the FiO2
The larger the jet size, the less air entrained and the higher the FiO2
The smaller the jet size, the more air entrained and the lower the FiO2
The jet is where the pressurized O2 source enters and transfers into the system, while the entrainment port pulls in surrounding air to mix with that O2. (COPD, and any patient requiring exact FiO2 control)
Aerosol mask: Delivers 21-100% O2 at flow rates of 8-15 L/min, mist should be available at all times to ensure adequate flow rates.
High-flow Nasal Cannula: Flows of up to 8 L/min are used on infants, and up to 60 L/min are used on adults, providing an O2 level of 90% (Acute hypoxemic respiratory failure; post extubation support)
FiO2 ranges:
COPD: 24-28%
Therapeutic (This includes COPD, but only when SpO2 is abnormally low < 88% or a PaO2 < 55): 30-60%
Emergency: 100%