ECG-Related Diagnostic Procedures
Special Procedures
Rhythm Strip
- An ECG run on lead II for 20 seconds is performed when something abnormal appears on the tracing or if requested by the Health Care Provider (HCP).
Inspiration Strip
- An ECG strip run on lead II for 10 seconds with the patient holding their breath.
Stress Testing
- Purpose: To evaluate a patient’s cardiac activity under activity or strain.
- Diagnostic procedure: Determines the likelihood of coronary artery disease (CAD), which is the blockage of arteries that supply the heart muscle.
- Used to evaluate patients with:
- High risk for developing heart disease.
- Known early heart disease.
- About to begin a strenuous exercise program.
- Cardiac complaints such as shortness of breath when exercising.
- Process:
- The treadmill test is noninvasive.
- Frequent blood pressure measurements are taken during exercise.
- The test continues until the maximum target heart rate is achieved or the patient becomes symptomatic.
Determining Maximum Target Heart Rate
- The maximum target heart rate is 85% of the patient’s maximum heart rate.
- Formula: (220−patient’s age)×0.85
- For patients post-myocardial infarction (MI), the target heart rate is set lower, at 70%.
Conclusion of Test
- The test concludes when the patient's symptoms, like chest pain or fatigue, or ECG changes indicate significant changes, especially in the ST segment.
- After the test, the patient rests while monitoring of blood pressure and heart rate continues until both are within normal range.
- Emergency carts should be on hand due to potential complications.
Exercise Stress Test
- The most used stress test is the exercise tolerance or stress test.
- It uses a treadmill to evaluate the patient’s heart’s response during moderate exercise.
- A 12-lead ECG is performed.
- The patient exercises on a bicycle or treadmill to stress the heart and increase the need for oxygen in heart muscle cells.
- A faster heart rate helps detect decreased blood flow.
- For patients with physical limitations, a stationary bicycle or pedal exerciser may be used.
Pharmacology Stress Test
- Uses heart-stimulating medication to mimic the effects of exercise.
- May include a vasodilator, such as adenosine or persantine, to dilate arteries.
- It evaluates blood flow to the heart using an EKG without physical activity.
- Recommended for patients with severe physical limitations, such as arthritis, joint or back conditions, and injury.
Nuclear Stress Test
- An imaging method that uses radioactive material to show how well blood flows into the heart muscle, both at rest and during activity.
- In many cases, the patient will perform an exercise stress test along with a nuclear stress test.
- The patient is injected with a radioactive substance, such as thallium or sestamibi, via an intravenous (IV) line during a stress test to better understand perfusion (blood flow to the myocardium).
- After injection, an imaging device scans the heart and creates images to show how the substance travels through the blood and into the heart.
- If the heart muscle is ischemic (receiving less than the normal amount of blood flow), poor uptake of the thallium will occur, indicated as a “cold spot” on the pictures.
- Normal perfusion of the myocardium is indicated by “hot spots” on the pictures.
- The test concludes when the patient’s symptoms of chest pain or fatigue or ECG changes indicate significant changes, especially to the ST segment.
- Monitoring of blood pressure and heart rate continue until both are within normal range.
- Emergency carts should be on hand due to potential complications.
Patient Preparation for Stress Tests
- Provide the patient with the scheduled date and time.
- Provide patient instruction and education about the procedure.
- Patients should wear comfortable exercise or walking shoes and loose-fitting clothes on the day of the test.
- Female patients should wear a bra to minimize artifacts on the ECG.
- Instruct patients not to eat a large meal for at least 4 hours before the test to avoid nausea.
- Patients should take their normal medications unless otherwise instructed by the health care provider.
- Inform the patient that baseline vital signs and a resting ECG are recorded first.
- Another ECG may be taken with the patient standing and hyperventilating (breathing rapidly).
- Rapid breathing can produce some changes in the ST segment and the T wave on the ECG recording.
- A thorough patient history is taken, emphasizing any symptoms, such as shortness of breath or chest pain.
- An ECG will be recorded as the patient walks or bikes at a carefully prescribed pace in the presence of the health care provider.
- Increases in rate or incline will be made, but the patient should not feel discomfort or shortness of breath.
Holter Monitor
- Records cardiac activity while the patient is ambulatory for at least a 24-hour period.
- Ordered if results of ECG are inconclusive or cardiac irregularity is not captured on tracing.
- Small recording device and patient diary used to detect heart irregularities that are infrequent and not detected on a standard 12-lead cardiogram.
- Most Holter monitors are digital recorders, but some medical offices may still use older models that use cassette tape recorders.
- The medical assistant may be required to instruct the patient and apply the chest electrodes.
- During patient preparation, stress the importance of the diary.
- Patients carry out all routine daily activities except showering or bathing.
- Patients use the diary to record their activities during the day, such as stair climbing, sexual activity, having bowel movements, sleeping, eating, exercising, and so forth.
- Five special disposable chest sensors are attached more securely than in 12-lead ECG because they must remain in place during all activity.
Sensor Placement
- Third intercostal space 2 or 3 inches to the right of the sternum.
- Third intercostal space 2 or 3 inches to the left of the sternum.
- Fifth intercostal space at the left sternum margin.
- Sixth intercostal space at the right anterior axillary line.
- Sixth intercostal space at the left anterior axillary line.
Procedure for Applying a Holter Monitor
- Assemble necessary supplies: Holter monitor with electrodes, patient cable, patient activity diary, fresh batteries or charging device, blank recording tape or digital flashcard or microchip, adhesive tape, razor, alcohol wipes, dry washcloth, patient’s electronic medical record.
- Install new batteries; depending on the model, make sure the digital storage unit (flashcard or microchip) has the maximum amount of memory. For older models, insert a new blank cassette tape.
- Verify that the machine is operational.
- Introduce yourself and then identify, interview, and instruct the patient according to office protocol. Explain the importance of accurately recording in the diary as well as depressing the event button at the correct times.
- Have the patient remove clothing to the waist (female patients may wear a gown open down the front) and sit on an examination table.
- Perform hand hygiene.
- Prepare the electrode sites by shaving small patches of chest hair where the electrodes will be placed (if necessary). Using alcohol wipes, wipe the skin to remove any residue that could interfere with electrode placement. Allow the skin to air dry.
- Using a dry washcloth or other abrasive material, rub the skin where the electrodes will be placed. This will help the electrodes stick to the skin more effectively.
- Attach the electrodes according to the manufacturer’s instructions. The electrodes will be placed in these locations: third intercostal space 2 or 3 inches to the right of the sternum, third intercostal space 2 or 3 inches to the left of the sternum, fifth intercostal space at the left sternum margin, sixth intercostal space at the right anterior axillary line, and sixth intercostal space at the left anterior axillary line.
- Attach the wires so that they point toward the feet, and then connect the patient cable.
- Secure each electrode with adhesive tape.
- Assist the patient with replacing his or her shirt. Extend the cable between the buttons or under the hem.
- Place the recorder in the carrying case and either attach it to the patient’s belt or place the neck strap around the patient’s neck. Check that there is no tension on the wires.
- Plug the cable into the recorder.
- Record the starting time in the diary.
- Ensure that the patient understands what to do by having the patient repeat the instructions for pressing the event button as well as what to record in the diary.
- Confirm the time for the patient to return to the clinic for removal of the Holter monitor.
- Chart the procedure in the patient’s record.
Charting Example
- Patient Name: Alan Jacobsen
- Patient DOB: 1/30/1959
- MR Number: 72720
- Date: 3/11/YY
- Time: 4:15 p.m.
- Chart Note: Holter monitor applied, and instruction given. Patient to return in 24 hours with diary and monitor. Patient verbalized understanding and repeated back instructions.
- Staff Member: E. Blodgett, CMA
Cardiac Event Monitor
- Used to capture a record of a cardiac event.
- Use the monitor until one event occurs and is recorded.
- For patients who have infrequent events, use the monitor for up to 30 days to ensure that any events will be captured.
- Electrodes are worn much as they would be for a Holter monitor.
- The patient presses a button on the monitor when perceiving a cardiac event.
- It records heart activity for five minutes after the depression.
- Some permit sending the information by telephone to the health care provider or to a receiving center.
- Patients may also keep a diary to align the event with activity at the time.
Mobile Cardiac Telemetry (MCT)
- Allows a device to send data continually to a facility that is staffed 24 hours per day.
- Information is monitored by a qualified, cardiac-trained registered nurse.
- MCT provides real-time monitoring and analysis.
- Telemetry monitors can have 3, 5, or 12 leads.
- Leads are placed according to the manufacturer’s instructions.
- Medical assistants help ensure patients understand how to use the telemetry monitor and are comfortable using the telemetry technology.
Pacemakers
- Electronic devices that help the heart maintain normal rhythm.
- Used to increase heart rate in patients with bradycardia (slow heart rate).
- Used to decrease heart rate in patients with tachycardia (rapid heart rate).
- Correct other dysrhythmias.
Temporary Pacemakers
- Used in acute settings to stabilize and maintain patients for shorter periods.
- Patients with temporary pacemakers must be hospitalized and continuously monitored.
- The pulse generator is located outside the body, and leads are threaded through specific veins to either the right atrium or the right ventricle.
- A temporary pacemaker may be attached during surgery to the outer surface of the heart.
- The wires then exit the chest and are attached to an external pulse generator.
Long-Term Pacemakers
- Many types of long-term devices exist, with the pulse generator implanted into the subcutaneous tissue of the upper chest.
- Leads are inserted into a major vein leading into the heart in the region of the myocardium that is impaired.
- The opposite ends of the leads are attached to the pulse generator.
- Long-term devices include single and dual chamber pacemakers and biventricular pacemakers.
- A single chamber pacemaker carries electrical impulses to the right ventricle of your heart.
- A dual chamber pacemaker carries electrical impulses to the right ventricle and the right atrium of the heart to help control the timing of contractions between the two chambers.
- A biventricular pacemaker is for patients with heart failure and an abnormal electrical system.
- It stimulates the lower chambers of the heart (the right and left ventricles) to make the heartbeat more efficiently.
- Most biventricular pacemakers implanted today can also work as implantable cardioverter defibrillators (ICD).
- ICDs restore a normal heartbeat by delivering a larger shock when a potentially deadly fast heart rhythm occurs.
Case Study Critical Thinking Questions
- Why is it important that David provide Mr. Masterson with a detailed explanation of the procedure? What should David tell him?
- When Mr. Masterson removes his shirt, David realizes that the patient has a very hairy chest. What should David do? Why?
- Mr. Masterson informs David that he has trouble lying flat on his back because of a previous injury from a car accident, and he does not think he will be able to lie flat for the ECG. How should David handle this situation?