Unit 5 - Equipment & Utilities

VI - I

  • Inputs are the raw materials needed for the production process, which include components, supplies, and energy sources essential for manufacturing.

  • Outputs are the products and waste that result from the process steps

  • Processes are activities that transform or work on materials. All process steps are included in a process doc(SOP)

Bioreactor - Apparatus that maintains optimal conditions for the growth of microorganisms, used in large-scale fermentation and in the commercial production of antibiotics, hormones, and other biologically derived pharmaceutical compounds.

Bioreactor controls the following:

  • Temp

  • PH

  • DissolvedOxygenn

  • Nutrient levels

All is tied to an EMI human-machine interface) for how you interact with the equipment.t


Therapeutic Cell Manufacturing

  • Upstream processes are those in which biological materials are either obtained from an outside source or inoculated and grown in culture, under controlled conditions, to manufacture certain types of products.

  • Downstream processes are those in which the products are harvested, tested, purified, and packaged.


Upstream: You are sourcing the cells, babysitting the bioreactor to ensure optimal growth conditions, and monitoring key parameters such as pH, temperature, and oxygen levels. (your main the primary ingredients

Downstream: Purification + recovery (taking the product and removing impurities) involves several critical steps, such as filtration, centrifugation, and chromatography, ensuring that the final product meets the required purity levels for safety and efficacy.

  • Harvest refers to taking the whole cell

  • Recvoery your takign a PART of the cell or something.

Centrifugation: Spins around to separate the liquid.

Purification: The process for eliminating impurities from the desired product within a crude mix; It can be the separation of unwanted proteins from the desired product.

  • Ultrafiltration vs. diafiltration (filtering between pore sizes)

  • Chromatogepahy

  • Chemical (degradants.)

API (Active pharmaceutical ingredient)

  • Blending API with protective excipients, solvents, and adjusting the pH to produce a stable product. (adds to product that doesn't have medicinal properties but is necessary)

  • Compounding (Only for solid products) also prepares powder compressed into tablets or filled into capsule.s

Fill/Finish

  • Involves putting precisely measured amounts of product into primary and secondary packaging components (vials, stoppers, overseals, blister pack, IV bags)

Common Tank Parts

Tanks: Storing and mixing

  • Reusable (fixed or mobile)

  • Disposable Tech

Tanks may be made of stainless steel, fiberglass-reinforced plastic, polypropylene, glass, aluminum, or other material.

  • Inspection ports are often installed at eye level also called sight glasses.

  • Manways are hatches that allow techs to enter a tank to clean and inspect i.t

  • Heating and cooling coils are tubes or coils mounted inside a tank that heat or cool tank contents

  • Jackets are a partial double around a tank that create a hollow space where heating or cooling can flow and be stable.

  • Pressure relief valves prevent overpressurization

  • Sampling ports, or sampling valves, are openings in the tank that allow for the collection of samples without compromising the integrity of the tank's contents.

  • Sensors mesuare variables

  • Spargers are tubes with tiny holes in them that bubble gas into the tank.

  • Spray balls, like shower heads, are used to clean the inside of a tank

  • Inlet and outlet valves control fluid flow into or out of a tank

  • Vents are openings built into the top of the tank through which gases escape to relieve pressure.

Piping consists of pipes, fittings, and joints that carry liquids, powders, or gases from one place to another. Can be made of different materials.

  • Pumps are the fluid movers in the process ,and in most c,ases are driven by electric motors, Such as centrifugal, positive displacement, rotary lobe, diaphragm, and peristaltic.altic

Functions of Valves:

  • Control the flow of fluids by opening, closing, or partially obstructing passageways.

  • Regulate pressure within the system by maintaining appropriate flow rates.

  • Prevent backflow, ensuring that fluids flow in one direction only.

  • Isolate sections of the piping system for maintenance or repair without having to drain the entire system.

Multi-turn valves: Make fluid go in any direction

  • Gate valve

  • Globe

  • Fixed Cone valve

  • diaphragm

  • neede

  • pinch

Quarter-turn valves

Ball valve

Vutterfly vlve

plug valve

spherical valve

Facility Utilities and Waste Treatment

Industrial utilities include the following:

  • Water treatment systems: Essential for maintaining water quality and ensuring compliance with environmental regulations.

  • Air handling units: Important for managing air quality and temperature in production areas. (gases)

  • Waste treatment facilities: Necessary for processing and disposing of waste materials safely.

  • Clean-in-place and steam-in-place systems Electricity

Gases

  • in chemcial reactions they provide the power to toperate vaves, transer proccess materials, bkanket process liquid and support cell growth.

Water can be used for cooling, heating, processing and cleaning.

  • FDA recgonizes 8 types of manufacturing water such as the follwoing

  1. non - potable water - Not suitable for drinking, but used in production processes where potable water is not required.

  2. Potable water - Water that is safe for drinking and is required for processes that come into contact with pharmaceuticals or consumables.

  3. Purified water - Water that has been processed to remove impurities, used in various applications within the pharmaceutical industry.

  4. Sterile water - Water that has been treated to eliminate living microorganisms, important for applications in sterile environments. (injection,inhalation)

  5. Water for injection (WFI) - Highly purified water used in the preparation of injectable medications, meeting specific microbiological and chemical standards.

  6. Bictersiostaic water for injection - Water that is free from bacteria and suitable for the preparation of parenteral solutions, adhering to stringent quality control measures.

  7. USP sterile water for irrgiation.


Water Treament for Pharmaceutical

Water used to manufavtur frugs must be water fo injectiong or (WFI or purisiftyed water

WFI- most purfitied, WFI is guranteed to be free of pyrogens,which are large molecules from bacteria that can cause fever if injected into the bloodstream.

Steam: Used for sterilization purposes, steam is generated by heating water to its boiling point, ensuring that all microbial life is eliminated.

Facility steam aka dirty team is made from less pure water and is used to teat waste and in other operations where purity is not critical.

Clean steam,made from WFI or another highly purfied form of water used for sterilizan,

Heating & Cooling Systems

  • Cooling ystems use coolant to remove heat from processes. The most common coolant is water

  • Heating systems add heat to porcesses. Steam is the most heat source

Lots of waste:

  • nonhaxrouds waste (office trash)

  • Haxarodus chem waste(neturialize befre city waste)

  • Biological waste(neturlize but differnly; kill off any cells/virsus)

  • Heat waste