Pharmocology

PMDI (pressurized metered dose inhalers

 Most commonly aerosol generators prescribed for patients with asthma and chronic obstructive  pulmonary disease (COPD).

 Small pressurized canisters for inhalation of aerosol drugs .

Contain multiple doses of accurately metered drug.

pMDI has 5 major components

  1. Canister

  2. Propellant

  3. Drug formulary

  4. Metering valve

  5. Actuator and dose counter

Advantages:

  • Portable

  • Efficient delivery

  • Treatment time is short

  • Easy to use

  • +100 doses

  • No drug preparation

  • Difficult to contaminate

Disadvantages:

 Complex hand and breathing coordination

 Drug concentrations and doses are fixed

 Canister depletion is difficult to determine accurately (See next slide)

 Reactions to the propellants may occur in small percentage of patients.

 High oropharyngeal impaction and loss occur if an extension device is not used.

Foreign body aspiration of debris from mouthpiece can occur

CFC and HFA:

one chlorofluorocarbon molecule can destroy 100,000 molecules of stratospheric ozone

Hydrofluoroalkane a propellant that is nontoxic to the atmosphere

 Unit dose dry powder inhalers: Individually wrapped capsules that contain a single dose of medication and deliver powder medication from a punctured capsule.

 Multiple unit dose DPI: dispense individual doses that are premetered into blisters. It is mechanically punctured when the cover is lifted.

 Multiple dose DPI: Multiple –dose DPIs measure the dose either from a powder reservoir.

  Factors affecting performance:

Intrinsic resistance: determines how much inspiratory flow must be created tin the device to release the correct amount of the drug.

 Inspiratory flow rate: Dispersal of drug depends on the energy of the inspiratory flow.

-­Moderate to high inspiratory flow is needed with DPIs

-­Affects: Children and Acute Asthmatic patients with airflow reduction

 Humidity: Can cause powder clumping and reduce degregation and the fine particle mass in the dose – DPI with reservoir chamber must be kept dry

Dry powder inhaler~

Advantages:

Breath actuation: no need for hand-breathing coordination

No inspiratory hold needed

Built in dose counter

Disadvantages:

Limited range of drug available.

Moderate to High inspiratory flow rates are needed for dispersion.

High oropharyngeal impaction and deposition

Some devices must be loaded before every use.

Humidity

MDI-emergency maintenance

DPI- general maintenance

Ideal particle size for deposition-3