Comprehensive Notes on Liquid Thermal Expansion, Thermometry, and Anomalous Expansion
Fundamentals of Real and Apparent Liquid Expansion
Liquid expansion is fundamentally volumetric expansion, as liquids possess no fixed shape and adopt the geometry of their containing vessel.
Real Expansion (Absolute Expansion):
- Real expansion describes the true physical increase in the volume of a liquid when heated, completely independent of any dimensional changes in the container.
- When an initial volume of liquid is heated through a temperature change of , its final volume is given by the governing equation:
- In this expression, represents the coefficient of real volume expansion (cubic expansivity) of the liquid, possessing the unit ^\n\circ\text{C}^{-1} or .
Apparent Expansion:
- When a liquid is heated inside a solid container, the container expands simultaneously. Because the real cubic expansivity of liquids is substantially greater than the volumetric expansivity of solids (), the liquid expands more than the container, resulting in an observable rise in liquid level or an overflow.
- The observable expansion of the liquid relative to the expanding vessel is defined as apparent expansion.
- The apparent expansion volume for an initial liquid volume subjected to a temperature rise is defined by:
- Here, (often denoted ) represents the coefficient of apparent expansion of the liquid relative to the vessel material.
Relationship Between Real and Apparent Coefficients:
- The solid container undergoes volumetric expansion determined by its linear expansivity , where the volumetric expansivity of an isotropic solid is .
- The true expansion of the liquid equals the expansion of the container plus the apparent expansion of the liquid:
- Dividing by yields the fundamental relation:
- Rearranging gives the apparent expansion coefficient:
Temperature Dependence of Liquid Density:
- Because the mass of a liquid remains invariant during heating while its volume expands, density decreases as temperature increases.
- If is the initial density at temperature and is the density at temperature :
Liquid-in-Glass Thermometer Sensitivity and Sensor Dynamics
Structural Components of a Liquid-in-Glass Thermometer:
- A thin-walled glass reservoir (bulb) containing the thermometric liquid (typically mercury or alcohol).
- A narrow capillary bore (stem) of uniform cross-sectional area into which the expanding liquid rises.
- An outer protective glass casing etched with a measurement scale.
- A safety bulb at the upper termination of the capillary to prevent overpressurization and rupture during accidental overheating.
Thermometric Heat Exchange and Measurement Inaccuracy:
- A thermometer measures temperature through thermal contact and subsequent thermal equilibrium with the target system.
- When immersed in a system with a small heat capacity (such as an isolated water droplet at ), the thermometer absorbs a significant fraction of the droplet's heat content to raise the temperature of the glass bulb and the thermometric liquid.
- Consequently, the droplet temperature drops drastically (e.g., from down to an equilibrium temperature of ), yielding an inaccurate measurement of the original state.
- Conversely, when measuring a large heat capacity system (such as a large water beaker at ), the energy absorbed by the thermometer causes a negligible perturbation to the surrounding temperature (e.g., cooling marginally to ), yielding high measurement accuracy.
Mathematical Derivation of Thermometer Sensitivity:
- In instrumentation, sensitivity () is defined as the ratio of the change in output signal to the corresponding change in physical input parameter.
- For an ammeter, the input is current () and the output is pointer angular deflection (), making sensitivity .
- For a liquid-in-glass thermometer, the physical input is the temperature change () and the output observation is the displacement or change in height () of the liquid meniscus along the capillary bore:
- When temperature increases by , the apparent volume expansion of the liquid in the glass bulb is accommodated by the capillary tube of uniform cross-sectional area :
- By the definition of apparent expansion, where is the internal volume of the bulb at the base reference temperature:
- Equating both volume expressions:
- Dividing across by yields the sensitivity formula:
- Expressing the cross-sectional area in terms of the internal bore diameter ():
Operational Parameters Influencing Sensitivity:
- Bulb Volume (): Sensitivity is directly proportional to bulb volume (). A larger initial reservoir yields a greater apparent volume expansion per degree.
- Bore Cross-Sectional Area () or Diameter (): Sensitivity is inversely proportional to the cross-sectional area (). A narrower capillary bore forces the expanded liquid along a greater axial length.
- Differential Expansivity (): Selecting a thermometric liquid with a large real cubic expansivity paired with a glass envelope of low linear expansivity maximizes the apparent expansion coefficient.
Analytical Problems on Thermometer Sensitivity
Problem 1: Determining Bulb Volume from Fixed-Point Calibration Data:
- Problem Statement: The distance along the capillary stem between the and calibration marks of a mercury-in-glass thermometer is . The cross-sectional area of the capillary bore is . Assuming the bulb is completely filled with mercury at and the apparent expansivity of mercury in glass is , calculate the internal volume of the bulb at .
- Given parameters:
- Derivation and Calculation:
- The required volume of the bulb at is approximately .
Problem 2: Comparative Sensitivity of Two Thermometers:
- Problem Statement: A mercury-in-glass thermometer shows a scale spacing of per . A second thermometer is constructed using the same mercury-glass combination and possesses the exact same bulb volume, but has a stem bore with half the cross-sectional area of the first. Determine the scale marking length per for the second thermometer.
- Given parameters:
- Analysis:
- Halving the stem cross-sectional area doubles the axial meniscus displacement, yielding a sensitivity of .
Molecular Basis and Thermodynamics of the Anomalous Expansion of Water
Standard Thermal Response in Fluids:
- In almost all liquids and materials, heating increases average molecular kinetic energy, increasing mean intermolecular separation and expanding volume (), which monotonically decreases density ().
- Cooling reduces molecular agitation, drawing molecules closer together and continuously decreasing volume down to the freezing point.
Anomalous Structural Behavior of Liquid Water:
- When water cools from ambient temperatures (e.g., or ) down toward , it behaves normally: thermal agitation subsides, molecules pack closer together, volume decreases, and density increases.
- Below down to , water exhibits anomalous expansion: its volume expands and its density decreases as temperature drops.
- Molecular Mechanism:
- Water () molecules possess an angular (bent) geometry with two polar covalent bonds and two lone pairs of electrons on the central oxygen atom.
- Strong directional electrostatic attractions occur between the lone electron pairs of oxygen atoms on one molecule and the partially positive hydrogen atoms on adjacent molecules, forming intermolecular hydrogen bonds.
- Above , thermal kinetic energy breaks and distorts these directional bonds, allowing molecules to pack relatively densely in disordered arrangements.
- At , as kinetic energy decreases further, hydrogen bonding stabilizes, forcing molecules into an open, highly structured three-dimensional hexagonal/cage-like lattice arrangement.
- Maintaining this rigid hydrogen-bonded framework requires greater intermolecular spacing than the disordered liquid state.
- Therefore, between and , the formation of this open lattice causes water to expand upon cooling.
Thermodynamic State Curves for Water:
- Volume vs. Temperature Graph:
- Decreases non-linearly from high temperatures down to a global minimum at exactly .
- From down to , the curve rises smoothly as volume increases.
- At , latent heat extraction causes a phase transition to solid ice, accompanied by an abrupt, discontinuous volume expansion.
- Below , solid ice behaves normally, contracting steadily with further temperature reduction.
- Density vs. Temperature Graph:
- Increases as temperature decreases from ambient down to a global maximum at .
- The maximum density of pure liquid water occurs at and equals:
- Below down to , density continuously decreases.
- At , density drops abruptly during the phase transition to ice (approximately ), explaining why ice floats buoyantly on liquid water.
- In solid ice below , density increases slightly as temperature drops due to standard thermal contraction of the solid lattice.
Limnological and Ecological Implications in Freezing Environments
Convection Dynamics During Lake Cooling Down to :
- When atmospheric temperatures drop during winter in sub-polar regions (e.g., Siberia, Greenland, Canada, Norway), heat is extracted from the exposed top surface of an open body of water.
- Water particles at the surface cool (e.g., from to , then down to ).
- As the surface water cools, its volume contracts and its density increases relative to the underlying warmer layers.
- The denser surface water sinks under gravity toward the lake bed, while warmer, less dense water from the depths rises to replace it, establishing a natural vertical convection current.
- This cyclical convection process persists continuously until the entire volume of the lake reaches the temperature of maximum density, exactly .
Cessation of Convection Below :
- Once the entire water body reaches , further cooling at the surface produces water at .
- Because the density of water at is less than at (), this colder surface water is buoyant and remains floating at the surface.
- Vertical natural convection ceases entirely because the densest water () already resides at the bottom.
- As heat continues to escape to the cold atmosphere, subsequent cooling to , , and remains confined to the uppermost layers.
Temperature Stratification and Ice Cover Formation:
- At , the surface layer freezes into ice. Because ice density is lower than water density, the solid sheet floats atop the water.
- Ice has low thermal conductivity, acting as an insulating blanket that drastically slows further heat loss from the underlying liquid water.
- Beneath the floating ice layer, a stable thermal gradient develops:
- The upper surface of the ice sheet attains thermal equilibrium with the ambient freezing atmosphere (e.g., , , or ).
- The lower surface of the ice in direct contact with liquid water remains locked at the phase transition point of .
- Moving downward into the liquid column beneath the ice, temperature increases monotonically through a thin boundary gradient: .
- The vast bottom region of the pond or lake remains liquid at an invariant .
Ecological Survival of Aquatic Fauna:
- Were water to behave as a normal liquid, surface water would cool, become denser, sink continuously, and freeze from the bottom upward, turning the entire body of water into solid ice.
- Because of anomalous expansion, lakes freeze exclusively from the surface downward, leaving liquid water at below.
- Aquatic organisms (such as fish, seals, and diverse benthic life) survive harsh winter seasons inside this insulated liquid sanctuary at .
Hydrostatic and Upthrust Problems Involving Thermal Expansion
Problem 1: Thermal U-Tube Differential Hydrostatic Manometer:
- Problem Statement: A liquid is contained inside a U-tube where the two vertical limbs are maintained at temperatures of and , respectively. At steady state, the equilibrium heights of the liquid columns in the two arms are measured to be and . Calculate the coefficient of real volume expansion () of the liquid.
- Physical Setup:
- Limb 1 is maintained at , supporting a height of liquid with density .
- Limb 2 is maintained at , supporting a height of liquid with density .
- The base horizontal arm connects the two columns. At the baseline reference level, hydrostatic pressures must balance.
- Hydrostatic Equilibrium Formulation:
- Density-Temperature Relation:
- Substitution and Algebraic Solution:
Problem 2: Thermal Variation of Upthrust and Apparent Mass:
- Problem Statement: An aluminum block has a mass in air of . When completely immersed in a liquid having a real cubic expansivity at , its apparent mass is measured as . Calculate its apparent mass when the liquid and block are heated to . (Given: linear expansivity of aluminum \alpha = 2.5 \times 10^{-5}\,^\circ\text{C}^{-1}$).\n * Theoretical Foundation:\n * A body suspended from a spring balance in a fluid experiences true downward gravitational force W = mgTU.\n * Equilibrium of forces: T + U = mg \implies T = mg - U.\n * The spring balance indicates an apparent weight W_a = Tgm_a:\n m_a = m - \frac{U}{g}\n * Upthrust is governed by Archimedes' principle: U = V \rho_L gV\rho_L is the liquid density.\n * Thus, the apparent mass reduction is:\n \Delta m = m - m_a = V \rho_L\n * Boundary Conditions at 0\,^\circ\text{C} (Case 1):\n m_{\text{real}} = 50\,\text{g}\n m_{a,0} = 33\,\text{g}\n \Delta m_0 = 50 - 33 = 17\,\text{g} = V_0 \rho_{L,0}\n * Boundary Conditions at 50\,^\circ\text{C} (Case 2):\n * At \theta = 50\,^\circ\text{C}, the volume of the aluminum block expands:\n V_{50} = V_0(1 + 3\alpha \theta)\n * The density of the liquid decreases:\n \rho_{L,50} = \frac{\rho_{L,0}}{1 + \gamma \theta}\n * The new apparent mass defect is:\n \Delta m_{50} = m_{\text{real}} - m_{a,50} = V_{50} \rho_{L,50} = V_0(1 + 3\alpha \theta) \left(\frac{\rho_{L,0}}{1 + \gamma \theta}\right)\n * Ratio Analysis and Binomial Approximation:\n \frac{\Delta m_{50}}{\Delta m_0} = \frac{1 + 3\alpha \theta}{1 + \gamma \theta} = (1 + 3\alpha \theta)(1 + \gamma \theta)^{-1}\n * Since \gamma \theta \ll 1, applying first-order binomial expansion:\n \frac{\Delta m_{50}}{\Delta m_0} \approx (1 + 3\alpha \theta)(1 - \gamma \theta) \approx 1 + (3\alpha - \gamma)\theta\n * Substituting numerical values (\theta = 50\,^\circ\text{C}):\n 3\alpha = 3(2.5 \times 10^{-5}) = 7.5 \times 10^{-5}\,^\circ\text{C}^{-1}\n \gamma = 2.0 \times 10^{-4} = 20.0 \times 10^{-5}\,^\circ\text{C}^{-1}\n 3\alpha - \gamma = 7.5 \times 10^{-5} - 20.0 \times 10^{-5} = -12.5 \times 10^{-5}\,^\circ\text{C}^{-1}\n (3\alpha - \gamma)\theta = (-12.5 \times 10^{-5})(50) = -625 \times 10^{-5} = -0.00625\n * Evaluating \Delta m_{50}:\n \Delta m_{50} = 17 \times (1 - 0.00625) = 17 \times 0.99375 \approx 16.89\,\text{g}\n * Determining new apparent mass m_{a,50}:\n m_{a,50} = 50 - 16.89 = 33.11\,\text{g}\n\n\n# Thermal Expansion Coupled with Mechanics and Center of Gravity\n\n* Problem Setup: Thermal Shift in Equilibrium Tilt of an L-Shaped Tube:\n * A thin tube of uniform cross-sectional area is bent at a right angle (90^\circ) into an L-shape and freely pivoted at the corner bend point A.\n * The shorter arm has length Lm.\n * The longer arm has length 2L2m3m).\n * The outer ends of both arms are closed.\n * The shorter arm is completely filled up to its mouth with a liquid possessing a cubic expansivity \gamma = 3.0 \times 10^{-3}\,^\circ\text{C}^{-1}.\n * The mass of the liquid is nine times the mass of the entire tube:\n m_{\text{liquid}} = 9 \times (3m) = 27m\n * The tube is suspended freely from point A. When cooled by \Delta\theta = 100\,^\circ\text{C}, the liquid contracts toward the outer closed end of the short arm, shifting the center of gravity of the liquid column.\n * The shorter arm makes an angle \alpha_1\alpha_2\frac{\tan(\alpha_1)}{\tan(\alpha_2)}.\n\n* Initial Equilibrium Analysis at State 1 (Before Cooling):\n * Shorter arm orientation: inclined at angle \alpha_1 to the vertical.\n * Perpendicular longer arm orientation: inclined at angle 90^\circ - \alpha_1 to the vertical.\n * Mass distribution:\n * Tube shorter arm: mass m\frac{L}{2} from bend A along the arm.\n * Liquid inside shorter arm: completely fills arm length L27m\frac{L}{2} from bend A.\n * Total mass residing on shorter arm = m + 27m = 28m\frac{L}{2} from A.\n * Tube longer arm: mass 2mL2L) from bend A along the longer arm.\n * Torque equilibrium about pivot point A (anticlockwise torque = clockwise torque):\n \tau_{\text{short}} = \tau_{\text{long}}\n (28mg) \left(\frac{L}{2}\right) \sin(\alpha_1) = (2mg) (L) \sin(90^\circ - \alpha_1)\n * Noting that \sin(90^\circ - \alpha_1) = \cos(\alpha_1):\n 14mgL \sin(\alpha_1) = 2mgL \cos(\alpha_1)\n 14 \sin(\alpha_1) = 2 \cos(\alpha_1)\n \tan(\alpha_1) = \frac{2}{14} = \frac{1}{7}\n\n* Second Equilibrium Analysis at State 2 (After Cooling by 100\,^\circ\text{C}):\n * When cooled by \Delta\theta = 100\,^\circ\text{C}27m remains invariant, but its volume contracts.\n * Assuming the cross-sectional area of the tube remains invariant, the new length L_2 of the liquid column is:\n L_2 = L(1 - \gamma \Delta\theta)\n L_2 = L(1 - 3.0 \times 10^{-3} \times 100) = L(1 - 0.3) = 0.7L\n * Because the outer end of the shorter arm is closed, the liquid settles against this closed end.\n * The center of gravity of the contracted liquid column lies at its midpoint, at a distance of \frac{L_2}{2} from the closed outer end.\n * Therefore, the distance y from pivot A to the new center of gravity of the liquid is:\n y = L - \frac{L_2}{2} = L - \frac{L(1 - \gamma \Delta\theta)}{2} = \frac{L}{2} + \frac{L \gamma \Delta\theta}{2} = L\left(\frac{1}{2} + 50\gamma\right)\n * Numerically, with \gamma \Delta\theta = 0.3:\n y = L - \frac{0.7L}{2} = L - 0.35L = 0.65L\n * The mass of the shorter arm material (m\frac{L}{2} = 0.5L.\n * Rotational equilibrium of torques about pivot A for angle \alpha_2:\n \tau_{\text{short}} = \tau_{\text{long}}\n \left[ mg \left(\frac{L}{2}\right) + 27mg (y) \right] \sin(\alpha_2) = (2mg) (L) \cos(\alpha_2)\n * Dividing across by mgL:\n \left[ \frac{1}{2} + 27\left(\frac{1}{2} + 50\gamma\right) \right] \sin(\alpha_2) = 2 \cos(\alpha_2)\n \left[ \frac{1}{2} + \frac{27}{2} + 1350\gamma \right] \sin(\alpha_2) = 2 \cos(\alpha_2)\n \left[ 14 + 1350\gamma \right] \sin(\alpha_2) = 2 \cos(\alpha_2)\n \tan(\alpha_2) = \frac{2}{14 + 1350\gamma}\n * Evaluating with \gamma = 3.0 \times 10^{-3}\,^\circ\text{C}^{-1}:\n 1350\gamma = 1350 \times 0.003 = 4.05 = \frac{81}{20}\n 14 + 1350\gamma = 14 + 4.05 = 18.05 = \frac{361}{20}\n \tan(\alpha_2) = \frac{2}{\frac{361}{20}} = \frac{40}{361}\n\n* Evaluation of the Tangent Ratio:\n * Taking the ratio of \tan(\alpha_1)\tan(\alpha_2):\n \frac{\tan(\alpha_1)}{\tan(\alpha_2)} = \frac{\frac{1}{7}}{\frac{40}{361}} = \frac{361}{7 \times 40} = \frac{361}{280}\n * This algebraic demonstration verifies the relation:\n \frac{\tan(\alpha_1)}{\tan(\alpha_2)} = \frac{361}{280}\n\n\n# Advanced Thermometer Design and Calibration Analysis\n\n* Benchmark Problem Setup (A/L 2006 Examination Model):\n * Internal volume of glass bulb at 0\,^\circ\text{C}V_0 = 1.0\,\text{cm}^3.\n * Linear expansivity of glass: \alpha = 3.0 \times 10^{-6}\,^\circ\text{C}^{-1}.\n * Real cubic expansivity of mercury: \gamma = 2.0 \times 10^{-4}\,^\circ\text{C}^{-1}.\n * Assume the volume of the capillary tube is negligible compared to the bulb volume, such that the mercury volume at 0\,^\circ\text{C}1.0\,\text{cm}^3.\n\n* Step-by-Step Analysis and Solutions:\n * Part 1: Internal Volume of the Glass Bulb at 100\,^\circ\text{C}:\n * Volumetric expansivity of glass: 3\alpha = 3(3.0 \times 10^{-6}) = 9.0 \times 10^{-6}\,^\circ\text{C}^{-1}.\n * Internal volume at 100\,^\circ\text{C}:\n V_{\text{bulb}, 100} = V_0(1 + 3\alpha \Delta\theta)\n V_{\text{bulb}, 100} = (1.0\,\text{cm}^3)[1 + (9.0 \times 10^{-6})(100)] = 1.0 \times [1 + 0.0009] = 1.0009\,\text{cm}^3\n * Part 2: Real Volume Increase of Mercury for a 100\,^\circ\text{C} Temperature Rise:\n * Real volume increase of mercury:\n \Delta V_{\text{Hg}} = V_0 \gamma \Delta\theta\n \Delta V_{\text{Hg}} = (1.0\,\text{cm}^3)(2.0 \times 10^{-4}\,^\circ\text{C}^{-1})(100\,^\circ\text{C}) = 0.02\,\text{cm}^3\n * Part 3: Apparent Volume of Mercury Displaced Up the Stem:\n * The volume of mercury forced to rise up the stem equals the difference between the real volume expansion of the mercury and the internal volume expansion of the glass bulb:\n \Delta V_{\text{stem}} = \Delta V_{\text{Hg}} - \Delta V_{\text{bulb}}\n \Delta V_{\text{stem}} = 0.02\,\text{cm}^3 - 0.0009\,\text{cm}^3 = 0.0191\,\text{cm}^3\n * Part 4: Cross-Sectional Area of the Stem for Specified Sensitivity:\n * The thermometer scale requires a 1\,^\circ\text{C}0.25\,\text{cm}.\n * For a \Delta\theta = 100\,^\circ\text{C} interval, the required displacement of the mercury column is:\n h_{100} = 0.25\,\text{cm}/^\circ\text{C} \times 100\,^\circ\text{C} = 25\,\text{cm}\n * Since \Delta V_{\text{stem}} = A h_{100}, the capillary bore cross-sectional area is:\n A = \frac{\Delta V_{\text{stem}}}{h_{100}} = \frac{0.0191\,\text{cm}^3}{25\,\text{cm}} = 7.64 \times 10^{-4}\,^\text{cm}^2\n * Underlying Fundamental Assumption: The bore of the capillary tube is assumed to have a perfectly uniform cross-sectional area along its entire functional length.\n * Part 5: Design of Safety Expansion Bulb A for Overheating Protection up to 300\,^\circ\text{C}:\n * The normal calibrated scale spans 0\,^\circ\text{C}100\,^\circ\text{C}300\,^\circ\text{C}.\n * The additional temperature range beyond the calibrated maximum is:\n \Delta\theta_{\text{excess}} = 300\,^\circ\text{C} - 100\,^\circ\text{C} = 200\,^\circ\text{C}\n * The apparent expansion per 100\,^\circ\text{C}0.0191\,\text{cm}^3.\n * Because apparent expansion is linear with temperature change, the additional apparent volume for an excess of 200\,^\circ\text{C}100\,^\circ\text{C}:\n V_A = 2 \times \Delta V_{\text{stem}, 100} = 2 \times 0.0191\,\text{cm}^3 = 0.0382\,\text{cm}^3\n * The minimum internal volume of safety bulb A must be 0.0382\,\text{cm}^3.\n * Part 6: Correction of Inaccurate Scale Markings:\n * Problem: A faulty thermometer has its nominal 0\,^\circ\text{C}100\,^\circ\text{C}-0.3\,^\circ\text{C}99.8\,^\circ\text{C}40\,^\circ\text{C}.\n * Formulation via linear interpolation of scale intervals:\n \frac{\theta_{\text{true}} - \theta_{\text{lower, actual}}}{\theta_{\text{upper, actual}} - \theta_{\text{lower, actual}}} = \frac{\theta_{\text{indicated}} - \theta_{\text{lower, indicated}}}{\theta_{\text{upper, indicated}} - \theta_{\text{lower, indicated}}}\n \frac{\theta_{\text{true}} - (-0.3)}{99.8 - (-0.3)} = \frac{40 - 0}{100 - 0}\n \frac{\theta_{\text{true}} + 0.3}{100.1} = \frac{40}{100} = 0.4\n \theta_{\text{true}} + 0.3 = 0.4 \times 100.1 = 40.04\n \theta_{\text{true}} = 40.04 - 0.3 = 39.74\,^\circ\text{C}\n * The true temperature corresponding to a reading of 40\,^\circ\text{C}39.74\,^\circ\text{C}.\n\n* Thermometric Fluid Comparison — Mercury vs. Alcohol:\n * Optical Opacity: Mercury is a completely opaque, silvery metallic liquid, making its meniscus easily readable against a graduation scale without the addition of dyes.\n * Thermal Conductivity and Responsiveness: As a liquid metal, mercury possesses a high thermal conductivity compared to organic liquids like alcohol, ensuring rapid heat transfer, minimal time lag, and a very short response time.\n * Non-Wetting Characteristics: Mercury does not wet glass (cohesive forces exceed adhesive forces), forming a convex meniscus that glides cleanly without clinging to the walls as droplets, preventing volumetric reading errors.\n * Saturated Vapor Pressure: Mercury has an extremely low saturated vapor pressure at standard operating temperatures. Consequently, the vacuum space above the column in the stem remains free of vapor pressure that would otherwise oppose column expansion.\n * Operational Temperature Range: Mercury has a high boiling point (357\,^\circ\text{C}-39\,^\circ\text{C}78\,^\circ\text{C}-114\,^\circ\text{C}$$, restricting its utility to low-temperature measurements.