Lecture 21: Mass Spectrometry, Microscopy, NMR, and X-ray Crystallography

Mass Spectrometry Fundamentals and Applications

  • Definition and Core Principle: Mass spectrometry (MS) is an analytical technique where molecules are converted into gaseous ions. Their mass-to-charge ratios (m/zm/z) are measured to identify and quantify molecules.

  • Analytical Capabilities:

    • Determining protein molecular weight with higher precision than any other technique.

    • Detecting miniscule amounts of a substance within a sample; Normal mass spectrometry alone is useful for analyzing very small molecules.

    • Pharmacokinetics: Tracking drugs and their metabolic pathways within the body.

  • Data Representation: Gaseous ions are separated in the mass spectrometer according to their m/zm/z ratio, and the relative amount (intensity) of different ions is plotted.

  • Diverse Examples of Application:

    • Isotope Detection: Identification of specific isotopic signatures.

    • Archaeology: Detection of Tetracycline in Sudanese bones dating back to 450 CE450\text{ CE}.

    • Microbiology: Bacterial identification. This method is faster (taking only minutes) and cheaper than traditional culture plates or genetic sequencing.

    • Contamination Analysis: Identifying foreign substances in samples.

Protein Mass Spectrometry and Ionization Methods

  • Complementary Nature: MS complements other biophysical and bioimaging techniques for protein analysis, enabling the determination of molecular weights, sequences, and interactions.

  • Proteomics: Capability to analyze the proteome of a single cell.

  • Electrospray Ionization (ESI):

    • Sample is kept in solution.

    • A high voltage (e.g., 3000 Volt3000\text{ Volt}) is applied to a spray needle.

    • Droplets release peptide ions which are then analyzed.

  • MALDI-TOF (Matrix-Assisted Laser Desorption/Ionization - Time of Flight):

    • Sample is embedded in a matrix.

    • A "Soft Laser Desorption" technique uses a laser to ionize the sample.

    • The time of flight is used to determine the mass.

  • LC-MS (Liquid Chromatography-Mass Spectrometry):

    • Often coupled with High-Performance Liquid Chromatography (HPLC).

    • The peptide mixture is first separated by a liquid chromatography column before entering the mass spectrometer.


  • Cross-linking: MS is used to determine protein-protein interactions via chemical cross-linking.

  • Example Complexes:

    • Cohesin: Responsible for chromosome alignment. Includes subunits like Pds5BPds5B, WaplWapl, SA1SA1, and Scc1Scc1.

    • Mitochondria ETC (Electron Transport Chain)

    • Nuclear Pore Complex (NPC): A massive structure analyzed using cross-linking.

      • Intermolecular links: Between different modules or within a single module.

      • Intramolecular links: Within a single protein.

Fluorescence and Confocal Microscopy

  • Fluorescence Microscopy: Excites fluorophores (such as GFP, specialized dyes, or quantum dots) and uses filters to detect the emitted light. These systems are frequently inverted.

  • Confocal Microscopy: Employs lasers to focus the fluorescence, allowing for the production of 3D images with high resolution.

  • Multiphoton Microscopy (Two-Photon): Allows for deep imaging of living tissue, reaching depths up to 1 mm1\text{ mm}.

  • Live Cell Imaging: Capable of recording dynamic processes in real-time, such as:

    • Mitosis.

    • Cell movement.

    • Protein translocation.

    • Cell spreading and division.


Electron and Atomic Force Microscopy

  • Resolution Limits: Fluorescence and confocal microscopy are limited by diffraction to approximately half the wavelength of light (~200 nm200\text{ nm} or 2000×2000\times magnification).

  • Electron Microscopy (EM): Electrons have much smaller wavelengths than photons.

    • Resolution: Can reach 50 pm50\text{ pm} (10,000,000×10,000,000\times magnification).

    • Transmission Electron Microscopy (TEM): The electron beam penetrates directly through the substance.

    • Scanning Electron Microscopy (SEM): Scans the surface to detect secondary electrons, producing detailed 3D images. Electron beam bounces off a gold-coated sample


  • Rotary Shadowing-TEM (RS-TEM): Uses dehydrated molecules coated with heavy metals (e.g., for visualizing Telomerase, DNA, or SMC proteins).

  • Cryo-Electron Microscopy (Cryo-EM):

    • Involves vitrifying (flash-freezing) samples.

    • Thousands of EM images are computationally merged together (Nobel Prize 20172017).

    • Can reach ~1.2 Å resolution (requires a Faraday cage to shield from external electromagnetic interference)

  • Atomic Force Microscopy (AFM):

    • Functions like a needle on a record or a tuning fork, reading vibrations at the molecular level.

    • Provides nanometer-level (nm\text{nm}) resolution.

    • Used to visualize processes like Myosin walking on actin, CRISPR activity, and individual bond formation.



Spectroscopy: CD, FTIR, and NMR

  • Circular Dichroism (CD) Spectroscopy:

    • Measures the difference in absorption between left-handed and right-handed polarized light.

    • Differences arise from structural asymmetry (chirality).

    • Applications: Calculating secondary structure (αhelices\alpha\text{helices} , β\beta sheet, turns, S−SS-S bonds), detecting modifications, and checking drug purity by distinguishing enantiomers.

  • Fourier Transform Infrared (FTIR) Spectroscopy:

    • Used infrared light to to analyze plasma membranes, identify microorganisms, and characterize secondary structure.

    • Quickly determine the secondary structure content of a protein you should use

  • Nuclear Magnetic Resonance (NMR) Spectroscopy:

    • Uses powerful oscillating magnetic fields to determine protein structures.

    • Requirements: Nuclei must have nonzero spins (odd numbers of protons and neutrons), such as 1H^1H, 13C^{13}C, and 15N^{15}N.

    • Resolution: To approximately 2−2.5 2-2.5\text{ }A

    • Advantages: Molecules are studied in solution, allowing for the analysis of flexibility, motion, and interactions.

    • Limitations: Traditionally limited to small structures (<30 kDa<30\text{ kDa}), though recent advances allow for analysis of structures over 100 kDa100\text{ kDa}.



X-Ray Crystallography

  • Overview: Analytical technique used to determine protein structures with extremely high resolution (1 A)

  • It requires a protein crystal with high order to diffract X-rays in specific directions

  • History:

    • Developed in 19121912 by the Braggs; Bragg’s Law: nl = 2d sin θ

    • Associated with at least 2929 Nobel Prizes.

    • Max Perutz and John Kendrew used heavy metals to solve the first structures: hemoglobin and myoglobin (Nobel Prize 19621962 ).

  • Structural Data Growth: Only seven structures were solved by 19711971; today there are over 200,000200,000.

The entire process from gene to structure can take years, and many structures are being solved by Structural Genomics Centers due to the workload

  • Process Overview:

    1. Cloning, expression, and purification of the protein.

    2. Crystallization (can take years; often handled by Structural Genomics Centers).

    3. Data collection (diffraction patterns with x rays).

    4. Structure determination.

It provides the highest resolution and has no upper kDa limit, but 30% of proteins are membrane-associated, and half of approved drugs target membrane proteins, yet they represent only 1% of structures solved via crystallography


  • Crystallization Thermodynamics: The protein must be moved from the undersaturated zone into the supersaturated state. The types of supersaturation include:

    • Metastable zone: Growth but no new nucleation.

    • Nucleation zone: Initial crystal formation.

    • Precipitation zone: Protein falls out of solution as an amorphous solid.

  • Symmetry and Space Groups:

    • The space group describes the symmetry of the crystal, which can be divided into 14 classes (Bravais lattices)

    • The orientation or symmetry of a crystal’s components or subunits relative to one another

  • smallest unit = asymmetric unit

  • smallest unit of repeat = unit cell

  • Data Collection:

    • Over 97% of structures are solved using synchrotrons.

    • Speed: Conventional machines collect 50005000 reflections in one week; synchrotrons collect 5 million5\text{ million} reflections per hour.



In phase (constructive):

  • Waves are perfectly synchronized. Their peaks and troughs align, causing their amplitudes to add together, resulting in a stronger, combined signal.

Out of phase (destructive):

  • Waves are not perfectly aligned. When they are exactly opposite (180 degrees out-of-phase), the peak of one wave aligns with the trough of the other, canceling each other out


Mathematical Framework and Solving the Structure

  • Fourier Transform (FT):

    • Decomposes waves into constituent frequencies.

    • The Fourier transform decomposes a wave into its constituent frequencies, and converts between real and reciprocal space

  • The Phase Problem:

    • Film and CCD detectors only measure intensities/amplitudes (∣F∣|F|); the phase of the light is lost during data collection.

    • Phases are required for Fourier synthesis to reconstruct the electron density map (final step)

    • Jerome Karle and Herbert Hauptman developed solutions for this problem (Nobel Prize 19851985).

    • Visual metaphor: Using intensities from a picture of a duck and phases from a picture of a cat results in an image that looks like a cat.

  • Phase Solution Methods:

    • Direct Methods: Brute force calculation for small molecules (<1000 atoms<1000\text{ atoms}) with high resolution.

    • Molecular Replacement: Using phases from a previously solved homologous (structurally similar) molecule.

    • Multiple Isomorphous Replacement (MIR): Soaking crystals with heavy metals and using a Patterson difference map to locate the metals and calculate phases.

  • Final Model Building: The result of the Fourier transform is an electron density map into which the amino acid sequence is modeled.

  • X-ray crystallography remains the highest resolution technique for accurate model building, typically in the 1.5−2.5A01.5-2.5A^0 range.