Comprehensive Billing, Usage, and Nomination Workflow Guide
Account Setup and Initial Verification
To begin account evaluation, navigate to the locator interface and input the company code for Oklahoma Natural Gas along with the customer name Superior Leaning Service Inc, Tulsa, then execute the search. The initial step upon retrieving an account involves navigating to billing and opening the bill summary to verify when the previous bill was generated. Account reviews often necessitate examining account details prior to extracting usage and nomination data. This specific account reflects a TLF designation, signifying a physical location in Tulsa. Accounts are billed based on their specific municipality or county, meaning rates vary across locations and accounts may incur penalties or local fees based on the town in which they reside.
Within the account pact screen, the configuration indicates a single service under a pro rata structure. Verifying the underlying pipeline association requires checking the billing component where the pro rata value is displayed. Accessing the service level under attributes confirms a value of blue red, which designates that the service operates on a blue-red pipeline. This pipeline assignment dictates the specific transportation and delivery components that ultimately populate the customer invoice.
Usage Entry and Background Job Processing
Usage data is retrieved by accessing the usage menu and navigating to usage entry. The date parameters are established by setting the start date to and the end date to , which sets up the billing cycle for August that will generate a bill dated for September. Executing the search initiates the download process. In the usage channels interface, two channels are displayed: channel under unit of measurement (UIM) DTH D (dekatherms per day) and MCF D (thousand cubic feet per day). The active billing calculation relies on the DTH D channel.
Clicking the blue Get Usage button pulls the raw volume data, causing the button to gray out once the command executes. Once retrieved, the daily background job must be executed by clicking the Daily button, which triggers the backend calculation of daily customer consumption. Viewing the DTH-d breakdown reveals that on the first day of August, the customer recorded zero consumption. On the second day of August, the customer consumed . Dekatherms represent standard billing units of natural gas reflecting energy content, comparable to physical meter reads. This consumption data originates from an automated integration with FlowCal, where the source type is classified as actual across all August dates. While the MCF field is linked to service , it does not require operational adjustments. Clicking the Monthly button executes the aggregate monthly calculation. Executing both the daily and monthly jobs is an absolute prerequisite for invoice creation; omitting them prevents the system from computing unit aggregates. Once both jobs complete and their respective buttons turn gray, clicking Save in the usage entry section commits the data and prompts the confirmation message: usage information is successfully updated.
Nomination Maintenance and Imbalance Calculation
After usage processing is saved, navigate to the usage history page to confirm that the pulled August usage volumes appear correctly. At this stage, the bill date field remains blank because billing generation has not yet occurred. Next, navigate to nomination maintenance to extract and process monthly nominations across the identical August timeframe. Establishing the nomination period from August through August and executing the search enables the blue Get Noms button, which populates the complete monthly nomination records.
Processing nominations requires running sequential calculation jobs. Clicking the Summarize button aggregates the nominations for the entire month using integrated data sourced directly from account setup records. Once summarization finishes, clicking the Daily Imbalance button initiates the daily imbalance job; after waiting several seconds, the screen is refreshed. Following the daily calculation, clicking the Monthly Imbalance button completes the final balance sequence. Unlike the usage entry screen, the nomination maintenance interface includes the preliminary Summarize step before calculating daily and monthly imbalances. Once these jobs execute, the action buttons disappear or gray out. Navigating to the customer nomination history page allows verification of gas date start and end parameters for August. This confirmation verifies that total monthly nominations and usage figures align with the values displayed on the usage history screen. The total and imbalance summary fields on this screen are integrated directly from auxiliary modules and require no manual alterations.
August Bill Summary Creation and Prior-Month Exception
To initiate invoicing for the August period, access the billing menu and open the bill summary screen, then select Create Bill Summary. Within the account code field, select the GT account number. Copying and selecting this number auto-populates the customer name, account class, and billing cycle. In the bill cycle month field, the value must be formatted with the four-digit year preceding the two-digit month, entered as for August . Clicking Save triggers a blue progress banner stating: Begin process is in progress and will take some time to complete. Please refresh the page after some time to get the latest updates.
After approximately ten seconds, refreshing the screen displays an initial bill status marked with a red asterisk as In Process. A subsequent refresh generates a green success notification: Bill Summary for Bill Summary Code and Company Oklahoma Natural Gas successfully generated. Simultaneously, a yellow exception warning appears: Bill summary status has been moved to error due to following reasons: Unprocessed bill exists for account and prior month . This operational error indicates that the preceding July billing cycle remains in Review status. The system enforces strict sequential billing, meaning an August invoice cannot be finalized while an unresolved prior-month bill exists for the account.
Banner Meter Reading Synchronization for July Bill
Resolving the unfinalized July bill requires entering missing meter data into Banner. In the bill summary search interface, locating the second entry from the top reveals the bill cycle month sitting in Review status. From this July record, copy the premise number located after the dash in the account identifier. In Banner, open the locator screen via the screwdriver icon on the far left gray tab, paste the premise number into the customer field under account information, and click Locate to retrieve customer records. The account records will confirm that no August line item exists, which corresponds to July usage within the GT system.
In the Banner header search bar, enter Random Meter Readings to load the meter entry screen. In regression testing environments, meter readings are typically pre-loaded, requiring only bill transmission to Banner; however, manual entry requires setting the read date to . Click the service query button to select the target service from the two services linked to the account. Return to the ONE Gas application and inspect the calculation details and usage details within the bill details screen to locate the exact positive usage integer, which is . In Banner, enter into the CR read - PR read field, designate the entry reason as Meter Reading, and save the transaction under File. The interface confirms the save with the system message: FRM- transaction complete. Two records applied and saved. Navigating to the service history query screen (UCISERH - Service History Query) verifies that the action date reflects August .
Billing Work Queue Approval and July Finalization
To approve the July invoice and transmit it to Banner, return to the ONE Gas application and navigate to billing work queue. Filter the queue by selecting Review under bill status, inputting into the bill month field, setting the creation start date to , and entering the GT account number into the account code field. Executing the search isolates a single queue item for July , which displays a bill status of Review, a bill transfer status of Not Sent, and a work status of Not Started.
Select the checkbox on the left side of the row, which highlights the item in blue. Click the Approve Selected button on the top right. A confirmation dialogue window appears stating: Confirm selected bills approval. You are approving of bills. Do you want to continue? Confirming with Yes initiates processing. Upon screen refresh, two notifications appear: a green message confirming Work Queue Status Updated Successfully and a blue message indicating Invoice generation process is in progress and will take some time to complete. Please refresh the page after some time to get the latest updates. Returning to the bill summary search confirms that the July bill cycle has moved to Complete status.
Legacy Usage Resolution and August Bill Generation
With the July cycle finalized, return to bill summary, locate the August bill, and click Generate to rerun backend calculation jobs. Upon refreshing the screen, a new yellow exception message appears: Bill summary status has been moved to error due to following reasons: no legacy usage found for service number and bill month . Device serial number, device number, device channel code, UIM. This condition requires manual entry within the usage validation table.
Navigate to usage entry, search for the August period, and inspect the usage channels. The calculated volume shows . System rules dictate that validation volumes must always be rounded up to the nearest whole integer, yielding a value of . In the usage validation section, click the Add button to open the Add Usage Validation pop-up. Select UIM as DTH, input the rounded figure into the usage field, and set the reading date to the first calendar day of the subsequent month, which is . Saving this entry returns the confirmation: Record created successfully for UIM DTH D.
Return to the bill summary screen and click Generate on the August record. The bill status shifts from Error to In Process alongside the banner: Billing process is in progress and will take some time to complete. Please refresh the page after some time to get the latest updates. Refreshing the browser updates the bill status from In Process to Review, with the bill file status marked as Not Sent, successfully finalizing the August billing calculation.
Bill Detail Review and Tariff Specifications
Accessing the bill detail interface reveals two distinct accounting pact lines: the CNO pact and the GT pact. Operational review focuses primarily on the GT pact line, which displays an active pact status, a bill cycle month of August , and a total invoiced amount of . Clicking the primary bill detail line opens the itemized rate breakdown.
The overview verifies the pipeline assignment as blue-red. Under pipeline charges, the bill assesses both a Delivery fee Red Pipeline and a Delivery fee Blue Pipeline, corresponding directly to the service attributes verified during account onboarding. Additionally, the invoice applies municipal franchise charges. Because this customer is located within Tulsa, the bill assesses a Tulsa Local Franchise (TLF) fee. Municipal penalty and franchise rates vary across jurisdictions; in cases where an account configuration reflects TLF equals N within the billing component, municipal fees are waived and will not populate on the final invoice.
Questions & Discussion
During the scheduling verification, clarification was sought regarding whether the active billing cycle represented July or August. The operational timeline confirmed that the cycle under configuration was August ( to ), which produces an invoice dated for September .
Regarding identifier entry in Banner, clarification was requested concerning whether to input the GT account number or the premise number into the customer locator text field. The required entry is the premise number, specifically identified as the secondary numeric string located after the hyphen in the GT account identifier.
In relation to standard regression testing, an inquiry addressed whether manual random meter readings must be entered for every test case. In standard regression testing environments, meter readings are pre-loaded automatically into the database, eliminating the need for manual record creation in Banner and leaving bill transmission as the only required Banner task.
A concluding query considered whether to execute a second meter reading in Banner to transmit the newly generated August invoice. The sequence for transmitting the August bill replicates the exact workflow completed for the July cycle: entering the corresponding meter reading, saving the record, and approving the generated record within the billing work queue.