Reinforced Concrete Design Reviewer

Structural Member Dimensioning Formulas

  • Beam Depth Calculation (YdY_d):

    • Unit: Millimeters (mm\text{mm}).
    • Formula: Yd=L×3.281×25.4Y_d = L \times 3.281 \times 25.4
    • Variable definition: LL is the longest span length of the beam.
  • Beam Width Calculation (ZdZ_d):

    • Unit: Millimeters (mm\text{mm}).
    • Proportion range: Specified as 50%50\% to 75%75\% of the beam depth (YdY_d).
    • Minimum width bound: Zd=0.50×YdZ_d = 0.50 \times Y_d
    • Maximum width bound: Zd=0.75×YdZ_d = 0.75 \times Y_d
  • Column Dimensioning (B/LB/L):

    • Formula: B/L=300+SnoB/L = 300 + S_{no}
    • Variable definition: SnoS_{no} represents the total number of storeys in the structure.

Material Strength Specifications

  • Concrete Compressive Strength (fc′f_c'):

    • Compressive strength value: fc′=28 MPaf_c' = 28\,\text{MPa}
  • Steel Reinforcement Yield Strength (fyf_y):

    • Main Longitudinal Reinforcement Bars: fy=420 MPaf_y = 420\,\text{MPa}
    • Shear Reinforcement / Ties / Stirrups: fy=280 MPaf_y = 280\,\text{MPa}

Structural Dead and Live Load Calculations

  • Dead Load (DL) Specifications:

    • Self-Weight: Calculated automatically or included as structural dead load.
    • Slab Floor Load:
    • Calculation: Slab Thickness (in m)×γc=Load in kN/m2\text{Slab Thickness (in m)} \times \gamma_c = \text{Load in kN/m}^2
    • Unit weight of concrete (γc\gamma_c): γc=25 kN/m3\gamma_c = 25\,\text{kN/m}^3
    • Stair Line Load:
    • Formula: (Assumed Thickness t in m×γc×Horizontal Length)×(12)=Line Load in kN/m(\text{Assumed Thickness } t \text{ in m} \times \gamma_c \times \text{Horizontal Length}) \times \left(\frac{1}{2}\right) = \text{Line Load in kN/m}
    • Concrete Hollow Block (CHB) Masonry Unit Loads:
    • Unit weight expression: Grout+γp(Slab+)(2)=Unit Weight in kN/m3\text{Grout} + \gamma_p (\text{Slab}+)(2) = \text{Unit Weight in kN/m}^3
    • Floor-Level CHB Wall Line Loads (2nd Floor to 5th Floor):
    • Formula: CHB Load×(Floor-to-Floor Height−Girder Depth)=Line Load in kN/m\text{CHB Load} \times (\text{Floor-to-Floor Height} - \text{Girder Depth}) = \text{Line Load in kN/m}
    • Roof Deck (RD) Level Stair CHB Wall Line Loads:
    • Formula: CHB Load×(Floor-to-Floor Height−Girder Depth at Stair)=Line Load in kN/m\text{CHB Load} \times (\text{Floor-to-Floor Height} - \text{Girder Depth at Stair}) = \text{Line Load in kN/m}
    • Roof Floor Parapet CHB Wall Line Loads:
    • Formula: CHB Load×Height of Parapet=Line Load in kN/m\text{CHB Load} \times \text{Height of Parapet} = \text{Line Load in kN/m}
    • CHB Masonry Wall Load Not Resting on Beams:
    • Formula: (Total Wall Length)×(Height of Wall)×(CHB Load)Floor Area=Area Load in kN/m2\frac{(\text{Total Wall Length}) \times (\text{Height of Wall}) \times (\text{CHB Load})}{\text{Floor Area}} = \text{Area Load in kN/m}^2
  • Live Load (LL) Specifications:

    • Stair Live Load Calculation:
    • Formula: 4.8 kN/m2×Horizontal Length×(12)=Line Load in kN/m4.8\,\text{kN/m}^2 \times \text{Horizontal Length} \times \left(\frac{1}{2}\right) = \text{Line Load in kN/m}

Structural Software Configuration and Design Standards

  • Base Configuration Settings:

    • General Base Unit System: Metric system.
    • Global Coordinate Axes: Y-axis oriented vertically upward (Y UPY \text{ UP}).
  • Design Codes and Standards:

    • Steel Design Standard: AISC 360-10
    • Concrete Design Standard: ACI 318-2011
    • Aluminum Design Standard: Aluminum US
    • Timber Design Standard: AITC 1994

Modelling Keyboard Shortcuts

  • 3D Modelling Toggle: CTRL + 4
  • View Rotation: Use keyboard direction arrow keys (Up, Down, Left, Right)
  • Change Cursor Mode: SPACE BAR
  • Return to Default Cursor: ESC
  • Display Beam Numbers: SHIFT + B
  • Display Incidences / Member Orientations: SHIFT + E
  • Display Views Menu Options: SHIFT + RIGHT CLICK