Hemodynamic Monitoring and Ventilation Management Notes
Hemodynamic Monitoring
- Preload: Filling pressure of the ventricle at the end of ventricular diastole.
- Right Ventricular Preload: Estimated by measuring right ventricular end-diastolic pressure (RVEDP).
- Contractility: The force that the ventricle generates during each cardiac cycle.
- Ejection Fraction: Estimates contractility, calculated as the ratio of stroke volume to ventricular end-diastolic volume.
- Afterload: Resistance the ventricle must overcome to eject blood.
- Systemic Vascular Resistance (SVR): Afterload for the left ventricle.
- Pulmonary Vascular Resistance (PVR): Afterload for the right ventricle.
- Ejection Fraction Calculation Example: If a patient has a stroke volume of 40 mL and an end-diastolic volume of 125 mL, the ejection fraction is .
- Venous Return: The most determining factor for preload, along with ventricular compliance.
Systemic Vascular Resistance and Afterload
- Increased by aortic pressure, SVR, aortic valve stenosis, and ventricular dilation.
- Increased afterload leads to increased end-systolic volume and decreased stroke volume.
- Afterload changes can secondarily alter preload.
- Increased afterload reduces stroke volume and increases left ventricular end-diastolic pressure (LVEDP), thus increasing preload.
- Frank-Starling mechanism compensates for reduced stroke volume due to increased afterload.
Hemodynamic Monitoring System
- Strain Gauge Transducer: Main component; uses a Wheatstone bridge circuit.
- Transducer Function: Converts fluid pressure to an electrical signal.
- Transducer Operation: Fluid enters the dome, moves the diaphragm, altering the Wheatstone bridge wires. Changes in wire length change resistance to current flow.
- Pressure changes are directly proportional to current flow change and inversely proportional to circuit resistance.
Arterial Line Insertion
- Catheter tip must face upstream (towards blood flow).
- The transducer must be level with the catheter tip for accurate pressure measurement.
- If the transducer is higher, readings will be lower than actual pressure.
Central Venous Pressure (CVP) Catheter
- Transducer placement: Mid-thoracic line (epistatic line), about 5 cm behind the angle of Louis.
- The measurement will be accurate if the transducer is at the epistatic line.
Troubleshooting Arterial Catheters
- Dampened waveform and difficulty withdrawing blood indicate a clot; remove the catheter to avoid embolism.
- Flushing can cause infarction in brain, heart, or lungs.
Allen Test
- Assesses ulnar collateral circulation before radial arterial line insertion.
- Positive Allen test: Refill time of 5-10 seconds (adequate circulation).
- Negative Allen test: Refill time >10 seconds (inadequate circulation); consider alternative site.
Complications of Systemic Artery Catheterization
- Ischemia, hematoma, hemorrhage, not phlebitis (inflammation of a vein).
Estimating Right Ventricular Preload
- Central venous pressure (CVP).
- Pulmonary artery occlusion pressure (PAOP) reflects left ventricular preload.
- Pulmonary artery pressure (PAP) measures right ventricular afterload.
CVP Catheter Placement
- Confirmed with chest radiograph
- Potential complications include pneumothorax, hemothorax, vessel damage, infection, thrombosis, and bleeding.
Pulmonary Artery Occlusion Pressure (PAOP)
- Low PAOP: Hypovolemia.
- Elevated PAOP: Volume overload, left ventricle failure, Mitral stenosis or regurgitation, Cardiac tamponade, Constrictive pericarditis, High PEEP
Pulmonary Artery Catheter Access
- Subclavian, internal jugular, external jugular, femoral, or antecubital veins.
- Surgical cut down often needed for subclavian or antecubital veins, especially in hypovolemic shock or trauma.
Pulmonary Artery Catheter Waveforms
- Right Atrium: 2-6 mm Hg with respiratory fluctuations.
- Right Ventricle: Systolic pressure up to 25 mm Hg.
- Pulmonary Artery: Systolic 15-35 mm Hg, Diastolic 5-15 mm Hg.
- Pulmonary Capillary (Wedged): 5-12 mm Hg.
Balloon Inflation for Pulmonary Artery Catheter
- Inflate upon entering the intrathoracic vessel to allow flow-directed movement.
- Protects the heart from damage and arrhythmias.
Contraindications for Pulmonary Catheter Insertion
- Avoid antecubital and femoral veins in patients with phlebitis.
Pulmonary Artery Catheter Movement
- Excessive movement can cause catheter knotting.
- Catheter whip: High cardiac output or abnormal vessel diameter.
- Balloon rupture: Loss of elasticity or overinflation.
- Dampened waveform: Air in line, clot, kinks, catheter tip against vessel wall, over-wedging, or blood on the transducer.
Pulmonary Artery Catheter Placement Accuracy
- Must be wedged in Zone 3 of the lungs for accurate readings.
- Zone 3 has a continuous column of blood between the catheter tip and the left atrium.
- Avoid Zones 1 and 2 due to alveolar pressure compression.
Pulmonary Artery Catheter Inflation Time
- 15-30 seconds to stabilize the reading and avoid complications.
Arterial Oxygen Content (CaO2) Calculation
- Formula:
Cardiac Output (CO) Calculation Using Fick Principle
- Formula:
Cardiac Index (CI) Calculation
- Formula:
Cardiac Output (CO) Calculation Using Stroke Volume and Heart Rate
* Formula: Stroke Index (SI) Calculation
- Formula: Stroke Index
Cardiac Cycle Time Calculation
* Formula: Left Ventricular Stroke Work Index (LVSWI) Calculation
- Formula:
Mean Arterial Pressure (MAP) Calculation
- Formula:
Right Ventricular Stroke Work Index (RVSWI) Calculation
- Formula:
Pulmonary Vascular Resistance (PVR) Calculation
- Formula:
Systemic Vascular Resistance (SVR) Calculation
- Formula:
Pulmonary Artery Occlusion Pressure (PAOP) Values
- Normal range: 5-12 mm Hg
- Mitral valve stenosis: Abnormally high PAOP, e.g., 20 mm Hg.
Central Venous Pressure (CVP) Values
- Normal range: 2-6 mm Hg
- Right heart failure: Elevated CVP, e.g., 16 mm Hg.
Systemic Vascular Resistance (SVR) and Causes of increase
* Hypovolemia causes an increase in SVR due to stimulation of the baroreceptor reflex
Hemodynamic Parameter Values
- Cardiac index (CI) = 2.5-4 L/min/m2
- Mixed venous oxygen content (CO2) = 15 vol%
- Mean arterial pressure (MPAP) = 10-20 mm Hg
- Pulmonary vascular resistance (PVR) = 100-250 dyne sec cm5
Pulmonary Artery Catheter Complications
- Catheter whip: High cardiac output
- Pulmonary infarction: Advancing catheter into a smaller artery or overinflation of the balloon
- Ventricular fibrillation: During the insertion process when the endocardium is irritated by the catheter while it is passing through the heart
Mechanical Influences on Pulmonary Artery Waveform
* During the inspiratory phase of spontaneous breathing there is decease in the PA waveform
Hemodynamic and Ventilator Management
* Elevated PAOP and PAP, along with CVP within normal limits indicates left ventricular failure. Settings above 15cmH2O will provide elevated pressure readings by squeezing pulmonary vessels, so it's recommended to lower PEEP incrementally.
Methods to Improve Ventilation in Patient-Ventilator Management
Minute Ventilation Adjustments
- Formula:
- Formula:
Tidal Volume
* Ranges between 6-8 mL/kg IBW
Causes of Metabolic Acidosis
* Overdose with salicylate
Causes of Metabolic Alkalosis
* Potassium deficiency
Issues of Persistent Respiratory Acidosis
* If after alveolar ventilation of a patient has been increased and respiratory acidosis persists, a cause can be increased dead space, which can caused by pulmonary embolism or low cardiac output
Sepsis and Mechanical Ventilation
* Metabolic rate and are elevated in patients with fever, burns, multiple trauma, sepsis, hyperthyroidism, muscle tremors or seizures, agitation, and in those patients who have undergone multiple surgical procedures
Iatrogenic Hyperventilation
* Iatrogenic hyperventilation causes lowered can leads to constriction of cerebral blood vessels, but is only recommended for brief periods of time
Permissive Hypercapnia
- Benefits patients with acute lung injury.
- Contraindicated in cerebral disorders and cardiovascular instability.
Deep Suctioning
- Insert catheter until resistance is met, then withdraw 1 cm before applying negative pressure.
Measuring Suction Catheter
- The catheter length should be long enough to reach a main-stem bronchus. This requires a catheter length of about 22 inches (56 cm).
Suction Catheter Size
- Appropriate size: Multiply the ET tube size by 3; this converts the ET size to French units (Fr). Then divide the result by 2, for a size that is half or less of the ET diameter.
Advantages of Closed Suctioning
- Decreased risk of infection for caregiver.
- No loss of PEEP during the procedure.
Administering Aerosols to Mechanically Ventilated Patients
* The primary advantage of using USNs and VMNs is that these devices produce smaller aerosol particles than pMDIs and SVNs without the addition of gas into the ventilator circuit.
Ventilator Graphics in Assessment Response to Bronchodilator
With VC-CMV, the volume-time scalar will remain constant. The expiratory portion of theflow-time scalar can show improvement if there is a response to the bronchodilator. The changes in PIP can be monitored with the pressure-time scalar and/or the pressure-volume loop.
Bronchoscopy of an Invasively Ventilated Patient.
* If after the bronchoscopy the patient is not arousable administer naloxone.
Dead Space Ratio
- Normal ratio of dead space to tidal volume (VD/VT): 0.2–0.4.
Fluid Balance and Positive Pressure.
* Positive-pressure ventilation increases the plasma antidiuretic hormone level.
EtCO2
- A decrease in EtCO2 and an increase in the PaCO2-to-PetCO2 gradient suggest increased dead space.